Single Box Fan

Airflow Direction: In

Permitted voltage fluctuation range (%): 85% to 110% rated voltage
Frequency (Hz): 50/60

ItemRated
voltage
(V)
Rated
rotational
speed
(r/min)*
Maximum
flow rate
(m3/min)*
Maximum
static pressure
(Pa)*
Noise (dB)*Weight
(g)
50 Hz60 Hz50 Hz60 Hz50 Hz60 Hz50 Hz60 Hz
R87B-FA1A15HPF
R87B-FA3A15HPF
R87B-FA4A15HPF
R87B-FA6A15HPF
100
115
200
230
2,7003,1001.31.5918549521,120
R87B-FA1A15LPF
R87B-FA3A15LPF
R87B-FA4A15LPF
R87B-FA6A15LPF
100
115
200
230
2,1002,2000.91.043424243
R87B-TA1A15HPF
R87B-TA3A15HPF
R87B-TA4A15HPF
R87B-TA6A15HPF
100
115
200
230
2,6503,0001.11.3676345481,150
R87B-TA1A15MPF
R87B-TA3A15MPF
R87B-TA4A15MPF
R87B-TA6A15MPF
100
115
200
230
2,3002,6000.81.041454144

Note:An asterisk (*) indicates a nominal value.

Airflow Direction: Out

Permitted voltage fluctuation range (%): 85% to 110% rated voltage
Frequency (Hz): 50/60

ItemRated
voltage
(V)
Rated
rotational
speed
(r/min)*
Maximum
flow rate
(m3/min)*
Maximum
static pressure
(Pa)*
Noise (dB)*Weight
(g)
50 Hz60 Hz50 Hz60 Hz50 Hz60 Hz50 Hz60 Hz
R87B-FA1A15HPFR
R87B-FA3A15HPFR
R87B-FA4A15HPFR
R87B-FA6A15HPFR
100
115
200
230
2,7003,1001.31.5918549521,120
R87B-FA1A15LPFR
R87B-FA3A15LPFR
R87B-FA4A15LPFR
R87B-FA6A15LPFR
100
115
200
230
2,1002,2000.91.043424243
R87B-TA1A15HPFR
R87B-TA3A15HPFR
R87B-TA4A15HPFR
R87B-TA6A15HPFR
100
115
200
230
2,6503,0001.11.3676345481,150
R87B-TA1A15MPFR
R87B-TA3A15MPFR
R87B-TA4A15MPFR
R87B-TA6A15MPFR
100
115
200
230
2,3002,6000.81.041454144

Note:An asterisk (*) indicates a nominal value.

The data in this table comes from measurements that were taken with the filter and cover attached.
The model number of the AC Axial-flow Fan in the Box Fan can be determined from the model number of the Box Fan as follows:

R87B-[]A[]A15[]PF(R)2
Double Box Fan

Airflow Direction: In

Permitted voltage fluctuation range (%): 85% to 110% rated voltage
Frequency (Hz): 50/60

ItemRated
voltage
(V)
Rated
rotational
speed
(r/min)*
Maximum
flow rate
(m3/min)*
Maximum
static pressure
(Pa)*
Noise (dB)*Weight
(g)
50 Hz60 Hz50 Hz60 Hz50 Hz60 Hz50 Hz60 Hz
R87B-FA1A15HPF2
R87B-FA3A15HPF2
R87B-FA4A15HPF2
R87B-FA6A15HPF2
100
115
200
230
2,7003,1002.63.0864855562,220
R87B-FA1A15LPF2
R87B-FA3A15LPF2
R87B-FA4A15LPF2
R87B-FA6A15LPF2
100
115
200
230
2,1002,2002.02.147444546
R87B-TA1A15HPF2
R87B-TA3A15HPF2
R87B-TA4A15HPF2
R87B-TA6A15HPF2
100
115
200
230
2,6503,0002.42.7686349522,260
R87B-TA1A15MPF2
R87B-TA3A15MPF2
R87B-TA4A15MPF2
R87B-TA6A15MPF2
100
115
200
230
2,3002,6001.61.941434447

Note:An asterisk (*) indicates a nominal value.

Airflow Direction: Out

Permitted voltage fluctuation range (%): 85% to 110% rated voltage
Frequency (Hz): 50/60

ItemRated
voltage
(V)
Rated
rotational
speed
(r/min)*
Maximum
flow rate
(m3/min)*
Maximum
static pressure
(Pa)*
Noise (dB)*Weight
(g)
50 Hz60 Hz50 Hz60 Hz50 Hz60 Hz50 Hz60 Hz
R87B-FA1A15HPFR2
R87B-FA3A15HPFR2
R87B-FA4A15HPFR2
R87B-FA6A15HPFR2
100
115
200
230
2,7003,1002.63.0864855562,220
R87B-FA1A15LPFR2
R87B-FA3A15LPFR2
R87B-FA4A15LPFR2
R87B-FA6A15LPFR2
100
115
200
230
2,1002,2002.02.147444546
R87B-TA1A15HPFR2
R87B-TA3A15HPFR2
R87B-TA4A15HPFR2
R87B-TA6A15HPFR2
100
115
200
230
2,6503,0002.42.7686349522,260
R87B-TA1A15MPFR2
R87B-TA3A15MPFR2
R87B-TA4A15MPFR2
R87B-TA6A15MPFR2
100
115
200
230
2,3002,6001.61.941434447

Note:An asterisk (*) indicates a nominal value.

The data in this table comes from measurements that were taken with the filter and cover attached.
The model number of the AC Axial-flow Fan in the Box Fan can be determined from the model number of the Box Fan as follows:

R87B-[]A[]A15[]PF(R)3
Triple Box Fan

Airflow Direction: In

Permitted voltage fluctuation range (%): 85% to 110% rated voltage
Frequency (Hz): 50/60

ItemRated
voltage
(V)
Rated
rotational
speed
(r/min)*
Maximum
flow rate
(m3/min)*
Maximum
static pressure
(Pa)*
Noise (dB)*Weight
(g)
50 Hz60 Hz50 Hz60 Hz50 Hz60 Hz50 Hz60 Hz
R87B-FA1A15HPF3
R87B-FA3A15HPF3
R87B-FA4A15HPF3
R87B-FA6A15HPF3
100
115
200
230
2,7003,1003.94.5865656583,380
R87B-FA1A15LPF3
R87B-FA3A15LPF3
R87B-FA4A15LPF3
R87B-FA6A15LPF3
100
115
200
230
2,1002,2002.93.142414748
R87B-TA1A15HPF3
R87B-TA3A15HPF3
R87B-TA4A15HPF3
R87B-TA6A15HPF3
100
115
200
230
2,6503,0003.54.0686350533,410
R87B-TA1A15MPF3
R87B-TA3A15MPF3
R87B-TA4A15MPF3
R87B-TA6A15MPF3
100
115
200
230
2,3002,6002.42.841454548

Note:An asterisk (*) indicates a nominal value.

Airflow Direction: Out

Permitted voltage fluctuation range (%): 85% to 110% rated voltage
Frequency (Hz): 50/60

ItemRated
voltage
(V)
Rated
rotational
speed
(r/min)*
Maximum
flow rate
(m3/min)*
Maximum
static pressure
(Pa)*
Noise (dB)*Weight
(g)
50 Hz60 Hz50 Hz60 Hz50 Hz60 Hz50 Hz60 Hz
R87B-FA1A15HPFR3
R87B-FA3A15HPFR3
R87B-FA4A15HPFR3
R87B-FA6A15HPFR3
100
115
200
230
2,7003,1003.94.5865656583,380
R87B-FA1A15LPFR3
R87B-FA3A15LPFR3
R87B-FA4A15LPFR3
R87B-FA6A15LPFR3
100
115
200
230
2,1002,2002.93.142414748
R87B-TA1A15HPFR3
R87B-TA3A15HPFR3
R87B-TA4A15HPFR3
R87B-TA6A15HPFR3
100
115
200
230
2,6503,0003.54.0686350533,410
R87B-TA1A15MPFR3
R87B-TA3A15MPFR3
R87B-TA4A15MPFR3
R87B-TA6A15MPFR3
100
115
200
230
2,3002,6002.42.841454548

Note:An asterisk (*) indicates a nominal value.

The data in this table comes from measurements that were taken with the filter and cover attached.
The model number of the AC Axial-flow Fan in the Box Fan can be determined from the model number of the Box Fan as follows:

R87B-N[]/R87B-PF
Optional Parts

R87B-N[] (Attachment)

ItemTypeWeight (g)
R87B-NSingle570
R87B-N2Double1,100
R87B-N3Triple1,700

R87B-PF01 (Replacement Filter)

ItemQty.Weight
(grams per filter)
R87B-PF0126