Global
| Shield | Unshielded |
|---|---|
| Cylinder type sensing head size | dia. 34 |
| Sensing method | Capacitive type |
| Sensing distance | 20 mm |
| Setting distance | 3 to 20 mm |
| Differential distance | 15% Max. of sensing distance(when adjusted to 20mm +10% to -10% with stndard object) |
| Sensing object | Conductor and dielectrics |
| Standard sensing object | With grounded metal 50*50*1mm |
| Response frequency | DC: 40 Hz (average) AC: 25 Hz (average) |
| Power supply voltage | 24 to 240 VDC 24 to 240 V |
| Operating voltage range | 20 to 250 VDC 20 to 250 VAC |
| Leakage current | 1.5 mA Max. (at 24VDC) 1.7 mA Max. (at 110VAC 50/60Hz) 2.5 mA Max. (at 250VAC 50/60Hz) |
| Control output (Output type) | AC/DC 2-wire models |
| Control output (Switching capacity) | 5 to 200 mA (resistive load) |
| Control output (Residual voltage) | (DC) 8 V Max. (AC) 10 V Max. (Refer to the Specifications) |
| Indicator | Operation indicator(yellow) |
| Operation mode | NC |
| Sensitivity setting | 15-turn adjustment(-3 to +3 turn) |
| Standard or Different frequency | Standard |
| Ambient temperature | Operating: -25 to 70 CEL Storage: -25 to 70 CEL (with no icing or condensation) |
| Ambient humidity | Operating: 35 to 95 %RH Storage: 35 to 95 %RH (with no condensation) |
| Temperature influence | +-15% Max. of sensing distance in temperature range of -10 to +55CEL +-25% Max. of sensing distance in temperature range of -25 to +70CEL (As the basis for sensing distance of 23CEL) |
| Voltage influence | +-2% Max. of sensing distance in rated voltage range +-15%. (As the basis for sensing distance at standard power voltage) |
| Insulation resistance | 50 M OHM Min. at 500VDC between charged parts and the case |
| Dielectric strength | 1500 VAC 50/60 Hz for 1 minute between charged parts and the case |
| Vibration resistance | 10 to 55 Hz, 1.5-mm double amplitude for 2 hours each in X, Y, and Z directions |
| Shock resistance | 500m/s2 for 10 times each in X, Y, and Z directions |
| Degree of protection | IEC60529: IP65 |
| Applicable standard (EC Directive (Low Voltage Directive)) | EN60947-1 EN60947-5-2 |
| Applicable standard (EC Directive (EMC Directive)) | EMI: EN60947-5-2 Emission Enclosure: CISPR11 Group 1 classA EMS: EN60947-5-2 Immunity ESD: IEC61000-4-2 Immunity RF-interference: IEC61000-4-3 Immunity Conducted Disturbance: IEC61000-4-6 Immunity Burst: IEC61000-4-4 CE marking: Equipped |
| Applicable standard (CCC mark) | Not equipped |
| Connection method | Pre-wired models (Cable length: 2 m) |
| Weight (Packed state) | approx. 240 g |
| Material (case) | PBT |
| Material (sensing surface) | PBT |
| Accessories | Instruction manual, Mounting bracket |
As of June 3, 2008