G3PC-220B-VD DC12-24

Ratings / Performance

Ratings
Product classification Solid State Relay for heater control
Input method Voltage input
Rated input voltage 12 to 24 VDC
Operating input voltage range 9.6 to 30 VDC
Must-operating voltage 9.6 VDC Max.
Reset voltage 1 VDC Min.
Isolation Phototriac
Input current 7 mA Max.
Output Form SPST-NO
Rated load voltage 100 to 240 VAC (50/60Hz)
Operating voltage range 75 to 264 VAC (50/60Hz)
Rated carry current AC: 0.1 A to 20 A (at 40 CEL)
Inrush current resistance (peak value) 220 A (at 60Hz/1cycle)
Output ON voltage drop Main circuit : 1.6V (RMS) Max.
Alarm output : 1.5V Max.
Leakage current Main circuit : 10mA Max. (at 200VAC)
Alarm output : 0.1mA Max. (at 24VDC)
Permissible I2t 260 A2s
Applicable load 4 kW (at 200VAC)
Conditions for SSR Failure Detection SSR short-circuit: Operating input (betweenterminals A1 and A2) OFF
SSR half-wave short-circuit: Operating input (betweenterminals A1 and A2) OFF
SSR open-circuit: Operating input (betweenterminals A1 and A2) ON
SSR half-wave open-circuit: Operating input (betweenterminals A1 and A2) ON
Conditions for SSR Failure Detection (Detection time) 0.5 s Max.
Conditions for SSR Failure Detection (Alarm display) RED
Alarm output Output OFF collector voltage: 30 VDC Max.
Maximum carry current: 0.1 A
Output form: Independent NPN open collector
Detection Power Supply Rated supply voltage: 100 to 240 VAC (50/60Hz)
Operating voltage range: 75 to 264 VAC (50/60Hz)
Current consumption: 15 mA Max. (at 200VAC)
Ambient temperature Operating: -20 CEL to 60 CEL
Storage: -30 CEL to 70 CEL
(with no icing or condensation)
Ambient humidity Operating: 45% RH to 85% RH
(with no icing or condensation)
Characteristics
Operate time 1/2 cycle of load power source + 1ms Max.
Release time 1/2 cycle of load power source + 1ms Max.
Protection for output Varisitor and Snubber
Zero cross function Provided
Indicator Input indicator(INPUT:Yellow:Operating)
Operating indicator(RDY:Green:NormalALM:Red:Failure detection and circuit disconnection detection)
Insulation resistance Between INPUT to LOAD: 100 M Ohm Min. (at 500 VDC)
Between Heat Sink to INPUT/OUTPUT Terminals: 100 M Ohm Min. (at 500 VDC)
Dielectric strength Between INPUT to LOAD: 2500 VAC 50/60 Hz for 1 min
Between Heat Sink to INPUT/OUTPUT Terminals: 2500 VAC 50/60 Hz for 1 min
Vibration resistance 10 to 55 to 10Hz 0.35mm single amplitude(0.7mm double amplitude)XYZ directions for 2hrs each
Shock resistance 294m/s2 each XYZX'Y'Z' directions for 3 times
Applicable standard (UL) Standard No.: UL508
File number: NO.E64562
Applicable standard (CSA) Standard No.: C22.2 NO.14
File number: No.LR35535
Applicable standard (VDE) Standard No.: EN60947-4-3
File number: NO.133114
Terminal structure screw
Terminal strength (Clamp torque) Recomendable fasten torque M3.5: 0.75 to 1.18N.m
Recomendable fasten torque M4: 0.98 to 1.47N.m
Mounting panel(DIN track)
Weight Approx. 300 g

As of December 5, 2007