H2C-8R AC240 50/60HZ 30H A

Ratings / Performance

Ratings
Rated supply voltage 240 VAC, 50/60Hz
Operating voltage range 85% to 110% of rated supply voltage
Power consumption (Relay ON) 4.2 VA, 3.96 W
Power consumption (Relay OFF) 4.2 VA, 3.96 W
Reset voltage 10% Max. of rated supply voltage
Number of time ranges 5
Time ranges 1.25 s to 30 s, 7.5 s to 3 min, 1.25 min to 30 min, 7.5 min to 3 h, 1.25 h to 30 h
Operating mode Power ON-delay
Control output Type Time-limit: SPST
Control output (Contact output) Switching capacities (resistive load (cos(phi)=1)): 250 VAC 6 A
Operating resetting Time-limit operation/Electric resetting
Ambient temperature Operating: -10 CEL to 50 CEL
Storage: -25 CEL to 65 CEL
(with no icing)
Ambient humidity Operating: 45% RH to 85% RH
Characteristics
Accuracy of operating time +/-0.5 % (FS) Max.
+/-1% Max. in a range of 6 s and 12 s
Setting error -2 % to 2 % (FS)
Reset time 0.5 s Max.
Influence of voltage +/-1% FS Max.
Influence of temperature +/-1% FS Max.
Insulation resistance 100 M Ohm Min.(at 500 VDC)
Dielectric strength between current-carrying metal parts and exposed non-curernt-carrying metal parts: 2500 VAC, 50/60 Hz for 1 min
between control output terminals and operating circuit: 2000 VAC, 50/60 Hz for 1 min
between contacts of different polarities: 2000 VAC, 50/60 Hz for 1 min
between contacts not located next to each other: 1000 VAC, 50/60 Hz for 1 min
Vibration resistance (Destruction) 10 to 55 Hz, 0.375 mm double amplitude each in X, Y, and Z directions for 1 hours
Vibration resistance (Malfunction) 10 to 55 Hz, 0.25 mm double amplitude each in X, Y, and Z directions for 10min
Shock resistance (Destruction) 1000 m/s2 3 times each 6 directions
Shock resistance (Malfunction) 150 m/s2 3 times each 6 directions
Mechanical Life expectancy (relay output) 10000000 operations Min. (under no load at 1800 operations/h)
Electrical Life expectancy (relay output) 200000 operations Min.(3A at 250 VAC, resistive load at 1800 operations/h)
Motor life expectancy 20000h
Degree of protection IEC60529(JEM): IP40
Applicable standard (UL) Standard No.: UL917
Applicable standard (CSA) Standard No.: CSA C22.2 No.14
Applicable standard (EC Directive (Low Voltage Directive) ) EN61812-1 / IEC60664-1 4kV/1
Applicable standard (EC Directive (EMC Directive) ) EMI: EN61812-1
Emission Enclosure: EN55011 Group1 class A
EMS: EN61812-1
Immunity ESD: IEC61000-4-2(6 kV contact discharge, 8 kV air discharge)
cRF-interference: IEC61000-4-3(10 V/m, AM radio waves (80 MHz to 1 GHz))
Immunity Burst: IEC61000-4-4(2kV power-line, 2kV I/O signal-line)
Immunity Surge: IEC61000-4-5(1 kV line to line, 2 kV line to ground)
External connection method 8-pin round socket
Case color Munsell 5Y7/1(Light gray)
Weight Approx. 180 g

As of January 17, 2008