Socket Characteristics

Model Rated carry
current
Dielectric strength Insulation
resistance *1
Remarks
P2RFZ-05(-E) 10 A Between contact terminals of same
polarity: 1,000 VAC for 1 min
1,000 MΩ min.
Between coil terminals and contact terminals:
4,000 VAC for 1 min
P2RFZ-08(-E) 6 A Between contact terminals of different
polarity: 3,000 VAC for 1 min
1,000 MΩ min.
Between contact terminals of same
polarity: 1,000 VAC for 1 min
Between coil terminals and contact terminals:
4,000 VAC for 1 min
P2R-05P 10 A Between contact terminals of same
polarity: 1,000 VAC for 1 min
1,000 MΩ min.
Between coil terminals and contact terminals:
4,000 VAC for 1 min
P2R-08P 5 A Between contact terminals of different
polarity: 3,000 VAC for 1 min
1,000 MΩ min.
Between contact terminals of same
polarity: 1,000 VAC for 1 min
Between coil terminals and contact terminals:
4,000 VAC for 1 min
P2R-057P 10 A Between contact terminals of same
polarity: 1,000 VAC for 1 min
1,000 MΩ min.
Between coil terminals and contact terminals:
5,000 VAC for 1 min
P2R-087P 5 A Between contact terminals of different
polarity: 3,000 VAC for 1 min
1,000 MΩ min.
Between contact terminals of same
polarity: 1,000 VAC for 1 min
Between coil terminals and contact terminals:
5,000 VAC for 1 min
P2R-05A 10 A Between contact terminals of same
polarity: 1,000 VAC for 1 min
1,000 MΩ min.
Between ground terminals: 1,500 VAC for 1 min
Between coil terminals and contact terminals:
4,000 VAC for 1 min
P2R-08A 5 A Between contact terminals of different
polarity: 3,000 VAC for 1 min
1,000 MΩ min.
Between contact terminals of same
polarity: 1,000 VAC for 1 min
Between ground terminals: 1,500 VAC for 1 min
Between coil terminals and contact terminals:
4,000 VAC for 1 min
P7TF-05 5 A Between terminals: 2,000 VAC for 1 min 1,000 MΩ min.
PYFZ-08(-E) 10 A Between contact terminals of different
polarity: 2,250 VAC for 1 min
1,000 MΩ min.
Between contact terminals of same polarity:
2,250 VAC for 1 min
Between coil terminals and contact terminals: 2,250
VAC for 1 min
PYF11A 5 A Between terminals: 2,000 VAC for 1 min 1,000 MΩ min.
PYFZ-14(-E) 6 A Between contact terminals of different
polarity: 2,250 VAC for 1 min
1,000 MΩ min.
Between contact terminals of same polarity:
2,250 VAC for 1 min
Between coil terminals and contact terminals: 2,250
VAC for 1 min
PY08(-Y1)(-Y3) 7 A Between terminals: 1,500 VAC for 1 min 1,000 MΩ min.
PY08QN(-Y1) 7 A Between terminals: 1,500 VAC for 1 min 100 MΩ min.
PY08-02 7 A Between terminals: 1,500 VAC for 1 min 100 MΩ min.
PY11(-Y1) 5 A Between terminals: 1,500 VAC for 1 min 100 MΩ min.
PY11QN(-Y1) 5 A Between terminals: 1,500 VAC for 1 min 100 MΩ min.
PY11-02 5 A Between terminals: 1,500 VAC for 1 min 100 MΩ min.
PY14(-Y1)(-Y3) 3 A Between terminals: 1,500 VAC for 1 min 100 MΩ min.
PY14QN(-Y1) 3 A Between terminals: 1,500 VAC for 1 min 100 MΩ min.
PY14-02 3 A Between terminals: 1,500 VAC for 1 min 100 MΩ min.
PTFZ-[][]-E 12 A (@70°C)
15 A (@50°C)
Between contact terminals of different
polarity: 2,500 VAC for 1 min
1,000 MΩ min.
Between contact terminals of same
polarity: 2,500 VAC for 1 min
Between ground terminals: 2,500 VAC for 1 min
Between coil terminals and contact terminals:
2,500 VAC for 1 min
PTF[][]A(-E) 10 A Between terminals: 2,000 VAC for 1 min 100 MΩ min.
PT[][] 10 A Between terminals: 2,000 VAC for 1 min 100 MΩ min.
PT[][]QN 10 A Between terminals: 2,000 VAC for 1 min 100 MΩ min.
PT[][]-0 10 A Between terminals: 2,000 VAC for 1 min 100 MΩ min.
P7LF-06 30 A Between contact terminals of different
polarity: 2,000 VAC for 1 min
1,000 MΩ min.
Between contact terminals of same
polarity: 2,000 VAC for 1 min
Between coil terminals and contact terminals:
4,000 VAC for 1 min
PF[][][]A 5 A Between terminals: 2,000 VAC for 1 min 1,000 MΩ min.
P2CF-[](-E) 5 A Between terminals: 2,000 VAC for 1 min 1,000 MΩ min.
8PFA(1) 10 A Between terminals: 2,000 VAC for 1 min 1,000 MΩ min.
11PFA(1) 10 A Between terminals: 2,000 VAC for 1 min 1,000 MΩ min.
P3G(A)-[] 6 A Between terminals: 2,000 VAC for 1 min 1,000 MΩ min.
PL[](-Q) 10 A Between terminals: 2,000 VAC for 1 min 1,000 MΩ min.
PLE[][]-0 10 A Between terminals: 2,000 VAC for 1 min 1,000 MΩ min.

*1. The insulation resistance was measured with a 500-VDC insulation resistance meter at the same places as
      those used for measuring the dielectric strength.
*2. However, do not exceed the continuous carry current of the socket to be mounted.