Model | Rated carry
current |
Dielectric strength | Insulation
resistance *1 |
Remarks |
---|---|---|---|---|
P2RFZ-05(-E) | 10 A | Between contact terminals of same
polarity: 1,000 VAC for 1 min |
1,000 MΩ min. | |
Between coil terminals and contact terminals:
4,000 VAC for 1 min |
||||
P2RFZ-08(-E) | 6 A | Between contact terminals of different
polarity: 3,000 VAC for 1 min |
1,000 MΩ min. | |
Between contact terminals of same
polarity: 1,000 VAC for 1 min |
||||
Between coil terminals and contact terminals:
4,000 VAC for 1 min |
||||
P2R-05P | 10 A | Between contact terminals of same
polarity: 1,000 VAC for 1 min |
1,000 MΩ min. | |
Between coil terminals and contact terminals:
4,000 VAC for 1 min |
||||
P2R-08P | 5 A | Between contact terminals of different
polarity: 3,000 VAC for 1 min |
1,000 MΩ min. | |
Between contact terminals of same
polarity: 1,000 VAC for 1 min |
||||
Between coil terminals and contact terminals:
4,000 VAC for 1 min |
||||
P2R-057P | 10 A | Between contact terminals of same
polarity: 1,000 VAC for 1 min |
1,000 MΩ min. | |
Between coil terminals and contact terminals:
5,000 VAC for 1 min |
||||
P2R-087P | 5 A | Between contact terminals of different
polarity: 3,000 VAC for 1 min |
1,000 MΩ min. | |
Between contact terminals of same
polarity: 1,000 VAC for 1 min |
||||
Between coil terminals and contact terminals:
5,000 VAC for 1 min |
||||
P2R-05A | 10 A | Between contact terminals of same
polarity: 1,000 VAC for 1 min |
1,000 MΩ min. | |
Between ground terminals: 1,500 VAC for 1 min | ||||
Between coil terminals and contact terminals:
4,000 VAC for 1 min |
||||
P2R-08A | 5 A | Between contact terminals of different
polarity: 3,000 VAC for 1 min |
1,000 MΩ min. | |
Between contact terminals of same
polarity: 1,000 VAC for 1 min |
||||
Between ground terminals: 1,500 VAC for 1 min | ||||
Between coil terminals and contact terminals:
4,000 VAC for 1 min |
||||
P7TF-05 | 5 A | Between terminals: 2,000 VAC for 1 min | 1,000 MΩ min. | |
PYFZ-08(-E) | 10 A | Between contact terminals of different
polarity: 2,250 VAC for 1 min |
1,000 MΩ min. | |
Between contact terminals of same polarity:
2,250 VAC for 1 min |
||||
Between coil terminals and contact terminals: 2,250
VAC for 1 min |
||||
PYF11A | 5 A | Between terminals: 2,000 VAC for 1 min | 1,000 MΩ min. | |
PYFZ-14(-E) | 6 A | Between contact terminals of different
polarity: 2,250 VAC for 1 min |
1,000 MΩ min. | |
Between contact terminals of same polarity:
2,250 VAC for 1 min |
||||
Between coil terminals and contact terminals: 2,250
VAC for 1 min |
||||
PY08(-Y1)(-Y3) | 7 A | Between terminals: 1,500 VAC for 1 min | 1,000 MΩ min. | |
PY08QN(-Y1) | 7 A | Between terminals: 1,500 VAC for 1 min | 100 MΩ min. | |
PY08-02 | 7 A | Between terminals: 1,500 VAC for 1 min | 100 MΩ min. | |
PY11(-Y1) | 5 A | Between terminals: 1,500 VAC for 1 min | 100 MΩ min. | |
PY11QN(-Y1) | 5 A | Between terminals: 1,500 VAC for 1 min | 100 MΩ min. | |
PY11-02 | 5 A | Between terminals: 1,500 VAC for 1 min | 100 MΩ min. | |
PY14(-Y1)(-Y3) | 3 A | Between terminals: 1,500 VAC for 1 min | 100 MΩ min. | |
PY14QN(-Y1) | 3 A | Between terminals: 1,500 VAC for 1 min | 100 MΩ min. | |
PY14-02 | 3 A | Between terminals: 1,500 VAC for 1 min | 100 MΩ min. | |
PTFZ-[][]-E | 12 A (@70°C)
15 A (@50°C) |
Between contact terminals of different
polarity: 2,500 VAC for 1 min |
1,000 MΩ min. | |
Between contact terminals of same
polarity: 2,500 VAC for 1 min |
||||
Between ground terminals: 2,500 VAC for 1 min | ||||
Between coil terminals and contact terminals:
2,500 VAC for 1 min |
||||
PTF[][]A(-E) | 10 A | Between terminals: 2,000 VAC for 1 min | 100 MΩ min. | |
PT[][] | 10 A | Between terminals: 2,000 VAC for 1 min | 100 MΩ min. | |
PT[][]QN | 10 A | Between terminals: 2,000 VAC for 1 min | 100 MΩ min. | |
PT[][]-0 | 10 A | Between terminals: 2,000 VAC for 1 min | 100 MΩ min. | |
P7LF-06 | 30 A | Between contact terminals of different
polarity: 2,000 VAC for 1 min |
1,000 MΩ min. | |
Between contact terminals of same
polarity: 2,000 VAC for 1 min |
||||
Between coil terminals and contact terminals:
4,000 VAC for 1 min |
||||
PF[][][]A | 5 A | Between terminals: 2,000 VAC for 1 min | 1,000 MΩ min. | |
P2CF-[](-E) | 5 A | Between terminals: 2,000 VAC for 1 min | 1,000 MΩ min. | |
8PFA(1) | 10 A | Between terminals: 2,000 VAC for 1 min | 1,000 MΩ min. | |
11PFA(1) | 10 A | Between terminals: 2,000 VAC for 1 min | 1,000 MΩ min. | |
P3G(A)-[] | 6 A | Between terminals: 2,000 VAC for 1 min | 1,000 MΩ min. | |
PL[](-Q) | 10 A | Between terminals: 2,000 VAC for 1 min | 1,000 MΩ min. | |
PLE[][]-0 | 10 A | Between terminals: 2,000 VAC for 1 min | 1,000 MΩ min. |