Page top

P2RF, P2R, P7TF, PYF, PY, PTF, PYD, PT, P7LF, PF, P2CF, PFA, P3G / P3GA, PL

Common Sockets

P2RF, P2R, P7TF, PYF, PY, PTF, PYD, PT, P7LF, PF, P2CF, PFA, P3G / P3GA, PL

A Wide Variety of Square and Round Sockets in Front-mounting and Back-mounting Models

Socket Characteristics

Model Continu-
ous carry
current
Dielectric strength Insulation
resistance
*1
Remarks
P2RF-05(-E) 10 A Between contact terminals of same
polarity: 1,000 VAC for 1 min
1,000 MΩ min.
Between coil and contact terminals:
4,000 VAC for 1 min
P2RF-08(-E) 5 A Between contact terminals of different
polarity: 3,000 VAC for 1 min
1,000 MΩ min.
Between contact terminals of same
polarity: 1,000 VAC for 1 min
Between coil and contact terminals:
4,000 VAC for 1 min
P2R-05P 10 A Between contact terminals of same
polarity: 1,000 VAC for 1 min
1,000 MΩ min.
Between coil and contact terminals:
4,000 VAC for 1 min
P2R-08P 5 A Between contact terminals of different
polarity: 3,000 VAC for 1 min
1,000 MΩ min.
Between contact terminals of same
polarity: 1,000 VAC for 1 min
Between coil and contact terminals:
4,000 VAC for 1 min
P2R-057P 10 A Between contact terminals of same
polarity: 1,000 VAC for 1 min
1,000 MΩ min.
Between coil and contact terminals:
5,000 VAC for 1 min
P2R-087P 5 A Between contact terminals of different
polarity: 3,000 VAC for 1 min
1,000 MΩ min.
Between contact terminals of same
polarity: 1,000 VAC for 1 min
Between coil and contact terminals:
5,000 VAC for 1 min
P2R-05A 10 A Between contact terminals of same
polarity: 1,000 VAC for 1 min
1,000 MΩ min.
Between ground terminals: 1,500 VAC
for 1 min
Between coil and contact terminals:
4,000 VAC for 1 min
P2R-08A 5 A Between contact terminals of different
polarity: 3,000 VAC for 1 min
1,000 MΩ min.
Between contact terminals of same
polarity: 1,000 VAC for 1 min
Between ground terminals: 1,500 VAC
for 1 min
Between coil and contact terminals:
4,000 VAC for 1 min
P7TF-05 5 A Between terminals: 2,000 VAC for 1 min 1,000 MΩ min.
PYF08A(-E) 7 A Between terminals: 2,000 VAC for 1 min 1,000 MΩ min. The continuous carry
current of 10 A for the
PYF08S is for an ambient
temperature of 55°C.
At an ambient temperature
of 70°C, the value is 7 A.
PYF11A 5 A Between terminals: 2,000 VAC for 1 min 1,000 MΩ min.
PYF14A(-E) 3 A Between terminals: 2,000 VAC for 1 min 1,000 MΩ min.
PY08(-Y1)(-Y3) 7 A Between terminals: 1,500 VAC for 1 min 1,000 MΩ min.
PY08QN(-Y1) 7 A Between terminals: 1,500 VAC for 1 min 100 MΩ min.
PY08-02 7 A Between terminals: 1,500 VAC for 1 min 100 MΩ min.
PY11(-Y1) 5 A Between terminals: 1,500 VAC for 1 min 100 MΩ min.
PY11QN(-Y1) 5 A Between terminals: 1,500 VAC for 1 min 100 MΩ min.
PY11-02 5 A Between terminals: 1,500 VAC for 1 min 100 MΩ min.
PY14(-Y1)(-Y3) 3 A Between terminals: 1,500 VAC for 1 min 100 MΩ min.
PY14QN(-Y1) 3 A Between terminals: 1,500 VAC for 1 min 100 MΩ min.
PY14-02 3 A Between terminals: 1,500 VAC for 1 min 100 MΩ min.
PTF[][]A(-E) 10 A Between terminals: 2,000 VAC for 1 min 100 MΩ min.
PT[][] 10 A Between terminals: 2,000 VAC for 1 min 100 MΩ min.
PT[][]QN 10 A Between terminals: 2,000 VAC for 1 min 100 MΩ min.
PT[][]-0 10 A Between terminals: 2,000 VAC for 1 min 100 MΩ min.
P7LF-06 30 A Between contact terminals of different
polarity: 2,000 VAC for 1 min
1,000 MΩ min.
Between contact terminals of same
polarity: 2,000 VAC for 1 min
Between coil and contact terminals:
4,000 VAC for 1 min
PF[][][]A(-E) 5 A Between terminals: 2,000 VAC for 1 min 1,000 MΩ min.
P2CF-[](-E) 5 A Between terminals: 2,000 VAC for 1 min 1,000 MΩ min.
8PFA(1) 10 A Between terminals: 2,000 VAC for 1 min 1,000 MΩ min.
11PFA(1) 10 A Between terminals: 2,000 VAC for 1 min 1,000 MΩ min.
P3G(A)-[] 6 A Between terminals: 2,000 VAC for 1 min 1,000 MΩ min.
PL[](-Q) 10 A Between terminals: 2,000 VAC for 1 min 1,000 MΩ min.
PLE[][]-0 10 A Between terminals: 2,000 VAC for 1 min 1,000 MΩ min.

* The insulation resistance was measured with a 500-VDC insulation resistance meter at the same places as those used for
   measuring the dielectric strength.