Model | Ratings | Standard No. | Certification No. | Number of Poles | Operating Coil Ratings | Contact Ratings |
---|---|---|---|---|---|---|
MY-[] (excluding "New" models) |
--- | EN61810-1 | R50030059 | 2 3 4 |
6 to 125V DC 6 to 240V AC |
MY2 5A 250V AC(cosφ=1.0) 2A 250V AC(cosφ=0.4) MY3 5A 250V AC(cosφ=1.0) 0.8A 250V AC(cosφ=0.4) MY4, MY4Z 3A 250V AC(cosφ=1.0) 0.8A 250V AC(cosφ=0.4) MYQ4 1A 250V AC(cosφ=1.0) 0.5A 200V AC(cosφ=0.4) |
LY-[] | --- | EN61810-1 | R50030064 | 1 2 3 4 |
6 to 110V DC 6 to 240V AC |
LY1 15A 110V AC(cosφ=1.0) 10A 110V AC(cosφ=0.4) LY2 10A 110V AC(cosφ=1.0) 7.5A 110V AC(cosφ=0.4) LY3, LY4 10A 110V AC(cosφ=1.0) 7.5A 110A AC(cosφ=0.4) LYQ2 3A 110V AC(cosφ=1.0) 10A 110V AC(cosφ=1.0) LY2Z 7A 110V AC(cosφ=1.0) 4A 110V AC(cosφ=0.4) |
MK-S | --- | EN61810-1 | R50104853 | 2, 3 | 6, 12, 24, 48, 100, 110V DC 6, 12, 24, 100, 110, 200, 220, 240V AC |
10A(NO)/5A(NC) 250 V AC (cosφ= 1.0) 10A(NO)/5A(NC) 30 V DC 7A 250V AC (cosφ=0.4) |
G7Z | --- | EN61810-1 | R50079155 | 4 | 12, 24V DC | NO contact: AC-1 40A 440V AC AC-3 16A 440V AC DC-1 5A 110V DC NC contact: AC-1 25A 440V AC DC-1 5A 110V DC |
G2RV-ST | --- | EN61810-1 | R50327609 | 1 | 12, 24V DC 24, 48V AC/DC 100, 110, 200, 230V AC |
Standard model 6A 250V AC 6A 30V DC 2A 400V AC Microloads model 50mA 30V AC 50mA 30V DC |
Model | Ratings | Standard No. | License No. | Operating Coil Ratings | Contact Ratings | Number of Poles |
---|---|---|---|---|---|---|
G6D-F4PU | --- | EN61810-1 | R50429253 | 12, 24V DC | Rated load voltage 250V AC 30V DC Load Current, General Use and Resistive 5 A at 40°C |
4PST-NO | G3DZ-F4PU | --- | EN62314 | R50429249 | Rated load voltage 5-240V AC 5-100V DC Load Current, General Use and Resistive 0.3 A at 55°C |
4PST-NO | P6DF-F4PU | --- | EN61984 | R50429224 | Contact terminal 5 A, 250 V |
4 |
Model | Ratings | Standard No. | Certification No. |
---|---|---|---|
G3NA-205B-UTU | 5A 240V AC | EN60950-1 | J50064193 | G3NA-210B-UTU | 10A 240V AC | EN60950-1 | G3NA-220B-UTU | 20A 240V AC | EN60950-1 | G3NA-225B-UTU | 25A 240V AC | EN60950-1 | G3NA-D210B-UTU | 10A 200V DC | EN60950-1 | G3NA-240B-UTU | 40A 240V AC | EN60947-4-3 | R50042088 | G3NA-250B-UTU | 50A 240V AC | EN60947-4-3 | G3NA-275B-UTU | 75A 240V AC | EN60947-4-3 | G3NA-290B-UTU | 90A 240V AC | EN60947-4-3 | G3NA-410B-UTU | 10A 480V AC | EN60947-4-3 | G3NA-425B-UTU | 25A 480V AC | EN60947-4-3 | G3NA-450B-UTU | 50A 480V AC | EN60947-4-3 | G3NA-475B-UTU | 75A 480V AC | EN60947-4-3 | G3NA-490B-UTU | 90A 480V AC | EN60947-4-3 | G3NE-205T(L)-US | 5A 240V AC | EN60950-1 | J50064183 | G3NE-210T(L)-US | 10A 240V AC | EN60950-1 | G3NE-220T(L)-US | 20A 240V AC | EN60950-1 | G3PE-215B(L) | 15A 240V AC | EN60947-4-3 | R50124433 | G3PE-225B(L) | 25A 240V AC | EN60947-4-3 | G3PE-235B(L) | 35A 240V AC | EN60947-4-3 | G3PE-245B(L) | 45A 240V AC | EN60947-4-3 | G3PE-515B(L) | 15A 480V AC | EN60947-4-3 | G3PE-525B(L) | 25A 480V AC | EN60947-4-3 | G3PE-535B(L) | 35A 480V AC | EN60947-4-3 | G3PE-545B(L) | 45A 480V AC | EN60947-4-3 | G3PE-215B-3(N)(H) | 15A 240V AC | EN60947-4-3 | G3PE-215B-2(N)(H) | EN60947-4-3 | G3PE-225B-3(N)(H) | 25A 240V AC | EN60947-4-3 | G3PE-225B-2(N)(H) | EN60947-4-3 | G3PE-235B-3(N)(H) | 35A 240V AC | EN60947-4-3 | G3PE-235B-2(N)(H) | EN60947-4-3 | G3PE-245B-3(N)(H) | 45A 240V AC | EN60947-4-3 | G3PE-245B-2(N)(H) | EN60947-4-3 | G3PE-515B-3(N)(H) | 15A 480V AC | EN60947-4-3 | G3PE-515B-2(N)(H) | EN60947-4-3 | G3PE-525B-3(N)(H) | 25A 480V AC | EN60947-4-3 | G3PE-525B-2(N)(H) | EN60947-4-3 | G3PE-535B-3(N)(H) | 35A 480V AC | EN60947-4-3 | G3PE-535B-2(N)(H) | EN60947-4-3 | G3PE-545B-3(N)(H) | 45A 480V AC | EN60947-4-3 | G3PE-545B-2(N)(H) | EN60947-4-3 | G3PF-225B(-CTB)(-STB) | 25A 240V AC | EN60947-4-3 | R50124941 | G3PF-235B(-CTB)(-STB) | 35A 240V AC | EN60947-4-3 | G3PF-525B(-CTB)(-STB) | 25A 480V AC | EN60947-4-3 | G3PF-535B(-CTB)(-STB) | 35A 480V AC | EN60947-4-3 | G3RV-ST700/500-A(L) | 2A 240V AC | EN62314 | R50559231 | G3RV-ST700/500-D(-H) | 3A 24V DC | EN62314 |
Model | Ratings | Standard No. | Certification No. |
---|---|---|---|
G3PW-220EU-C | 20A 240V AC | EN60947-4-3 | R50120135 | G3PW-245EU-C | 45A 240V AC | EN60947-4-3 | G3PW-260EU-C | 60A 240V AC | EN60947-4-3 | G3PW-220EC-C-FLK | 20A 240V AC | EN60947-4-3 | G3PW-245EC-C-FLK | 45A 240V AC | EN60947-4-3 | G3PW-260EC-C-FLK | 60A 240V AC | EN60947-4-3 | G3PW-220EU-S | 20A 240V AC | EN60947-4-3 | G3PW-245EU-S | 45A 240V AC | EN60947-4-3 | G3PW-260EU-S | 60A 240V AC | EN60947-4-3 | G3PW-220EC-S-FLK | 20A 240V AC | EN60947-4-3 | G3PW-245EC-S-FLK | 45A 240V AC | EN60947-4-3 | G3PW-260EC-S-FLK | 60A 240V AC | EN60947-4-3 |
Model | Ratings | Standard No. | Certification No. | Operating Coil Ratings | Contact Ratings |
---|---|---|---|---|---|
G7Z | --- | EN60947-4-1 | No.R50079155 | 12V DC 24V DC |
NO contact: AC-1:40A 440V 50/60Hz AC-3:16A 440V 50/60Hz DC-1:5A 110V *AC-15:0.5A 440V 50/60Hz *DC-13:0.5A 110V NC contact: AC-1:25A 440V 50/60Hz DC-1:5A 110V *AC-15:0.5A 440V 50/60Hz *DC-13:0.5A 110V |
G73Z | --- | --- | NO contact: AC-15:0.5A 440V 50/60Hz DC-13:0.5A 110V NC contact: AC-15:0.5A 440V 50/60Hz DC-13:0.5A 110V |
*Auxiliary contact ratings |
Model | Ratings | Standard No. | Certification No. |
---|---|---|---|
J7KC-12 | 12A 440V AC 55º C max |
EN60947-4-1 | R50441800 | J7KCA | AC-15: 3A 120V / 3A 240V / 1A 440V / 0.5A 600V DC-13: 2A 24V / 1A 48V / 0.3A 110V / 0.2A 220V 60º C max |
EN60947-5-1 | R50441993 | J7KCR | - | - | - | J73KC-AM | AC-15: 3A 120V / 3A 240V / 1A 440V / 0.5A 600V DC-13: 2A 24V / 1A 48V / 0.3A 110V / 0.2A 220V 55º C max |
EN60947-5-1 | R50442021 | J76KC-RC | 55º C max | EN60947-4-1 | R50441800 | 60º C max | EN60947-5-1 | R50441993 | J7MC-3P | 240-690V AC 60º C max |
EN60947-2 | R50441701 | J7MC-3R | J73MC | J7TC | 5A 55º C max |
EN60947-4-1 | R50441800 |