Model Ratings Standard No. File No. Category Listed/Recognized Contact Ratings Number of Poles
MY ( )
(New model)
6 to 240V AC
6 to 220V DC
UL508 E41515 NRNT2 Recognized 10A 30V DC (General Use)
10A 250V AC (General Use)
7A, 240VAC (General use)
7A, 24VDC (Resistive)
5A, 240VAC (General use)
5A, 250VAC (Resistive)
5A, 30VDC (Resistive)
3A, 265VAC (Resistive)
1/6 HP, 250VAC
1/8 HP, 265VAC
1/10 HP, 120VAC
B300 Pilot Duty (Same polarity)
2
UL508 NRNT2 Recognized 5A 250V AC(Resistive)(Same polarity)
5A 30V DC (Resistive)(Same polarity)
5A, 28VDC (General use)(Same polarity)
5A, 240VAC (General use)(Same polarity)
0.2A, 120VDC (Resistive)(Same polarity)
1/6HP, 250VAC (Same polarity)
1/10HP, 120VAC (Same polarity)
B300 Pilot Duty (Same polarity)
4
MY ( )
(Excluding New model)
6 to 240V AC
6 to 220V DC
UL508 NRNT2 Recognized 7A, 240VAC (General Use)
7A, 24VDC (Resistive)
5A, 30VDC (Resistive)
5A 240V AC (General Use)
5A, 250VAC (Resistive)
3A, 265VAC (Resistive)
1/6 HP, 250VAC
1/8 HP, 265VAC
1/10 HP, 120VAC
B300 Pilot Duty(Same polarity)
2
UL508 NRNT2 Recognized 5A、28VDC(Resistive)
5A, 240VAC(General Use)
1/6 HP, 250VAC
3
UL508 NRNT2 Recognized 5A, 28VDC (General Use)(Same polarity)
5A 240V AC (General Use)(Same polarity)
5A, 30VDC (Resistive)(Same polarity)
5A, 250VAC (Resistive)(Same polarity)
0.2A, 120VDC (Resistive)(Same polarity)
1/6 HP, 250VAC
1/10 HP, 120VAC
B300 Pilot Duty(Same polarity)
4
LY 6 to 240V AC
6 to 125V DC
UL508 E41643 NLDX2 Recognition 15A 120V AC (General use)
15A 240V AC (General use)
15A 30V DC (Resistive)
1/2HP 120V AC
8.5FLA 30LRA 120V AC
TV-5 120V AC
470VA Pilot duty 120V AC
1
Recognition 15A 120V AC (General use)
12A 240V AC (General use)
7A 250V AC (General use)
15A 30V DC (Resistive)
5A 38V DC (Resistive)
1/2HP 120V AC
1/3HP 240V AC
8.5FLA 30LRA 120V AC
5FLA 50LRA 50V DC
TV-3 120V AC
345VA Pilot duty 120-240V AC
B300/R300
2
Recognition 10A 240V AC (General use) (Same polarity)
10A 30V DC (General use) (Same polarity)
2A 40V DC (Resistive) (Same polarity)
1/2HP 240V AC
0.6A 100V DC (Resistive) (Same polarity)
3
4
G2R- ( ) -S 6~240V AC
5~110V DC
UL508 E41643 NLDX2 Recognized 10A 30V DC (Resistive)
10A 250V AC (General Use)
TV-3 (N. O. only)
1
UL508 NLDX2 Recognized 5A 30V DC (Resistive)
5A 250V AC (General Use)
TV-3 (N. O. only)
2
MK()-US 6 to 260V AC
6 to 130V DC
UL508 E41515 NRNT2 Recognized Ag contacts
5A 230V AC (Resistive)
5A 28V DC (Resistive)
2
3
MK( )-US 6 to 260V AC
6 to 130V DC
UL508 NRNT2 Recognized Ag contacts
5A 230V AC (Resistive)
5A 28V DC (Resistive)
2
3
MK-S 6 to 240V AC
6 to 125V DC
UL508 NRNT2, NRNT8 Recognized 10A 250V AC (Resistive)
10A 28V DC (Resistive)
7A 250V AC (General Use)
2
3
G7J- ( ) -P (Z)
G7J- ( ) -B (Z)
G7J- ( ) -T (Z)
24 to 240V AC
6 to 110V DC
UL508 E41643 NLDX2 Recognized NO contact (Single Contact)
25A 277V AC (Resistive)
25A 120V AC (General Use)
25A 277V AC (General Use)
1.5kW 120V AC (Tungsten)
1.5HP 120V AC
3HP 240/265/277V AC
3-phasa 3HP 240/265/277V AC
3-phasa 5HP 240/265/277V AC
20FLA/120LRA 120V AC
17FLA/102LRA 277V AC
TV-10 120V AC
25A 30V DC (Resistive)
4PST-NO
3PST-NO/
SPST-NC
DPST-NO/
DPST-NC
UL508 NLDX2 Recognized NC contact (Single Contact)
8A 277V AC (Resistive)
8A 120V AC (General Use)
8A 277V AC (General Use)
8A 30V DC (Resistive)
UL508 NLDX2 Recognized NO contact(Twin Contacts)
1A 277V AC(General Use)
UL508 NLDX2 Recognized NC contact (Twin Contacts)
1A 277V AC (General Use)
G7T-1122S 12 to 125V DC
24 to 240V AC
UL508 E41643 NLDX2 Recognized 1A 125V AC (Resistive)
1A 125V DC (Resistive)
5A 30V DC (Resistive)
1A 250V AC (General Purpose)
SPST-NO
G7T-1112S UL508 NLDX2 Recognized 5A 125V AC (Resistive)
5A 250V AC (General Use)
10A 250V AC (General Use)
10A 30V DC (Resistive)
1/2HP 240V AC
SPST-NO
G2RV-ST 12, 24V DC
24, 48V AC/DC
100, 110, 200, 230V AC
UL508 E41515 NRNT2, NRNT8 Listed Standard model
6A 250V AC (Resistive)
6A 30V DC (Resistive)
2A 400V AC (Resistive)

Microloads model
50mA 30V AC (Resistive)
50mA 30V DC (Resistive)
1

Terminal Relays

Regarding UL standard, product is certified by UL, but can also be certified by CSA in some cases. Check information for CSA certification as well.
Relays CSA Certification
See category for classification of UL Standard and CSA Standard.
Category for classification of UL Standard
Model Ratings Standard No. File No. Category Listed/Recognized Contact Ratings Number
of Poles
G6B-4( )
(except for G6B-48BND, G6B-4CB)
3~24V DC UL508 E87929 SWIV2 Recognized 5A 250V AC(General Use)
5A 30V DC(Resistive)
1/6HP 250V AC
1/8HP 250V AC
360WT 120V AC(Tungsten)
250VA 125V AC(Pilot Duty)
250VA 250V AC(Pilot Duty)
26.4VA 30V DC(Pilot Duty)
530VA 20 to 265V AC(Pilot Duty)
TV-2 120V AC TV rating
4
G6B-47( ) 3~24V DC UL508 SWIV2 Recognized 8A 250V AC(General Use)
8A 30V DC(Resistive)
1/6HP 250V AC
1/8HP 250V AC
360WT 120V AC(Tungsten)
250VA 125V AC(Pilot Duty)
26.4VA 30V DC(Pilot Duty)
530VA 20 to 265V AC(Pilot Duty)
TV-2 120V AC TV rating
4
G6D-F4B 12, 24V DC UL508 SWIV2 Recognized 5A 250V AC
5A 30V DC
4PST-NO
G3DZ-F4B UL508 SWIV2 Recognized 0.3A 3 to 264V AC
0.3A 3 to 125V DC
4PST-NO
G6D-F4PU UL508 E41515 NRNT/7 Listed Rated load voltage
250V AC
30V DC

Load Current, General Use and Resistive
5 A at 40°C
4PST-NO
G3DZ-F4PU UL508 NRNT/7 Listed Rated load voltage
5-240V AC
5-100V DC

Load Current, General Use and Resistive
0.3 A at 55°C
4PST-NO
P6DF-F4PU UL508 SWIV2 Recognized Contact terminal
5 A, 250 V
4

I/O Relay Terminals

Regarding UL standard, product is certified by UL, but can also be certified by CSA in some cases. Check information for CSA certification as well.
Relays CSA Certification
See category for classification of UL Standard and CSA Standard.
Category for classification of UL Standard
Model Ratings Standard No. File No. Category Listed/Recognized Contact Ratings
G7TC --- UL508 E95399 NRAQ2 Recognized Input:
250V max.

Output:
24V DC 10mA per relay contact

Total 160mA or 16terminal type
Total 80mA or 8terminal type
G70A-ZOC16-[] --- NRAQ2 Recognized 10A 250V AC
G70D-VSOC16 --- NRAQ2 Recognized 3A 250V AC
3A 30V DC
G70D-VFOM16 --- NRAQ2 Recognized 0.3A 3 to 264V AC
0.3A 3 to 125V DC

Solid-state Relays

Regarding UL standard, product is certified by UL, but can also be certified by CSA in some cases. Check information for CSA certification as well.
Relays CSA Certification
See category for classification of UL Standard and CSA Standard.
Category for classification of UL Standard
Model Ratings Standard No. File No. Category Listed/Recognized Output Ratings
G3PA-210B-VD --- UL508 E64562 NMFT2 Recognized 10A 240V AC
G3PA-220B-VD --- UL508 NMFT2 Recognized 20A 240V AC
G3PA-240B-VD --- UL508 NMFT2 Recognized 40A 240V AC
G3PA-260B-VD --- UL508 NMFT2 Recognized 60A 240V AC
G32A-A10-VD --- UL508 NMFT2 Recognized 10A 240V AC
G32A-A20-VD --- UL508 NMFT2 Recognized 20A 240V AC
G32A-A40-VD --- UL508 NMFT2 Recognized 40A 240V AC
G32A-A60-VD --- UL508 NMFT2 Recognized 60A 240V AC
G3PA-420B-VD(-2) --- UL508 NMFT2 Recognized 20A 400V AC
G3PA-430B-VD(-2) --- UL508 NMFT2 Recognized 30A 400V AC
G32A-A420-VD(-2) --- UL508 NMFT2 Recognized 20A 400V AC
G32A-A430-VD --- UL508 NMFT2 Recognized 30A 400V AC
G3PA-420B-VD-2 --- UL508 NMFT2 Recognized 20A 480V AC
G3PA-430B-VD-2 --- UL508 NMFT2 Recognized 30A 480V AC
G3PA-450B-VD-2 --- UL508 NMFT2 Recognized 50A 480V AC
G32A-A420-VD-2 --- UL508 NMFT2 Recognized 20A 480V AC
G32A-A430-VD-2 --- UL508 NMFT2 Recognized 30A 480V AC
G32A-A450-VD-2 --- UL508 NMFT2 Recognized 50A 480V AC
G3NE-205T(L)(-2)-US --- UL508 NMFT2 Recognized 5A 240V AC
G3NE-210T(L)(-2)-US --- UL508 NMFT2 Recognized 10A 240V AC
G3NE-220T(L)(-2)-US --- UL508 NMFT2 Recognized 20A 240V AC
G9H-205S-US --- UL508 NMFT2 Recognized 5A 250V AC
G9H-210S-US --- UL508 NMFT2 Recognized 10A 250V AC
G3TA-IAZR02S-US --- UL508 NMFT2 Recognized 25mA 32V DC
G3TA-IDZR02S(M)-US --- UL508 NMFT2 Recognized 25mA 32V DC
G3TA-OA202SZ-US --- UL508 NMFT2 Recognized 2A 250V AC
G3TA-OA202SL-US --- UL508 NMFT2 Recognized 2A 250V AC
G3TA-ODX02S-US --- UL508 NMFT2 Recognized 2A 60V DC
G3NA-205B(-UTU) --- UL508 NMFT2 Recognized 5A 240V AC
G3NA-210B(-UTU) --- UL508 NMFT2 Recognized 10A 240V AC
G3NA-220B(-UTU) --- UL508 NMFT2 Recognized 20A 240V AC
G3NA-240B(-UTU) --- UL508 NMFT2 Recognized 40A 240V AC
G3NA-410B --- UL508 NMFT2 Recognized 10A 480V AC
G3NA-420B --- UL508 NMFT2 Recognized 20A 480V AC
G3NA-440B --- UL508 NMFT2 Recognized 40A 480V AC
G3NA-450B(-UTU) --- UL508 NMFT2 Recognized 50A 480V AC
G3NA-D210B(-UTU) --- UL508 NMFT2 Recognized 10A 200V DC
G3NA-275B-UTU --- UL508 NMFT2 Recognized 75A 240V AC
G3NA-290B-UTU --- UL508 NMFT2 Recognized 90A 240V AC
G3NA-475B-UTU --- UL508 NMFT2 Recognized 75A 480V AC
G3NA-490B-UTU --- UL508 NMFT2 Recognized 90A 480V AC
G3H-203S(L)(N)-VD --- UL508 NMFT2 Recognized 3A 240V AC
G3HD-X03S(N)-VD --- UL508 NMFT2 Recognized 3A 48V DC
G3F-202SN-VD --- UL508 NMFT2 Recognized 3A 240V AC
G3F-203S(L)(N)-VD --- UL508 NMFT2 Recognized 3A 48V DC
G3FD-X03S(N)-VD --- UL508 NMFT2 Recognized 3A 48V DC
G3FD-102S(N)-VD --- UL508 NMFT2 Recognized 2A 110V DC
G3J-T205BL(-C)/S205BL --- UL508 NMFT2 Recognized 0.75kW(4.8A) 240V AC
G3J-T211BL(-C)/S211BL --- UL508 NMFT2 Recognized 2.2kW(11.1A) 240V AC
G3J-T217BL(-C) --- UL508 NMFT2 Recognized 3.7kW(17.4A) 240V AC
G3J-T403BL/S403BL --- UL508 NMFT2 Recognized 0.75kW(2.4A) 400V AC
G3J-T405BL/S405BL --- UL508 NMFT2 Recognized 2.2kW(5.5A) 400V AC
G3J-205BL(-2) --- UL508 NMFT2 Recognized 0.75kW(4.8A) 240V AC
G3J-211BL(-2) --- UL508 NMFT2 Recognized 2.2kW(11.1A) 240V AC
G3PE-215B(L) --- UL508 NMFT2 Recognized 15A 240V AC
G3PE-225B(L) --- UL508 NMFT2 Recognized 25A 240V AC
G3PE-235B(L) --- UL508 NMFT2 Recognized 35A 240V AC
G3PE-245B(L) --- UL508 NMFT2 Recognized 45A 240V AC
G3PE-515B(L) --- UL508 NMFT2 Recognized 15A 480V AC
G3PE-525B(L) --- UL508 NMFT2 Recognized 25A 480V AC
G3PE-535B(L) --- UL508 NMFT2 Recognized 35A 480V AC
G3PE-545B(L) --- UL508 NMFT2 Recognized 45A 480V AC
G3PE-215B-3(N)(H) --- UL508 NMFT2 Recognized 15A 240V AC
G3PE-215B-2(N)(H) --- UL508 NMFT2 Recognized
G3PE-225B-3(N)(H) --- UL508 NMFT2 Recognized 25A 240V AC
G3PE-225B-2(N)(H) --- UL508 NMFT2 Recognized
G3PE-235B-3(N)(H) --- UL508 NMFT2 Recognized 35A 240V AC
G3PE-235B-2(N)(H) --- UL508 NMFT2 Recognized
G3PE-245B-3(N)(H) --- UL508 NMFT2 Recognized 45A 240V AC
G3PE-245B-2(N)(H) --- UL508 NMFT2 Recognized
G3PE-515B-3(N)(H) --- UL508 NMFT2 Recognized 15A 480V AC
G3PE-515B-2(N)(H) --- UL508 NMFT2 Recognized
G3PE-525B-3(N)(H) --- UL508 NMFT2 Recognized 25A 480V AC
G3PE-525B-2(N)(H) --- UL508 NMFT2 Recognized
G3PE-535B-3(N)(H) --- UL508 NMFT2 Recognized 35A 480V AC
G3PE-535B-2(N)(H) --- UL508 NMFT2 Recognized
G3PE-545B-3(N)(H) --- UL508 NMFT2 Recognized 45A 480V AC
G3PE-545B-2(N)(H) --- UL508 NMFT2 Recognized
G3PF-225B(-CTB)(-STB) --- UL508 NMFT2 Recognized 25A 240V AC
G3PF-235B(-CTB)(-STB) --- UL508 NMFT2 Recognized 35A 240V AC
G3PC-220B-VD --- UL508 NMFT2 Recognized 20A 240V AC
G3RV-ST700/500-A(L) --- UL508 E41515 NRNT2, NRNT8 Listed 2A 240V AC
G3RV-ST700/500-D(-H) --- UL508 NRNT2, NRNT8 Listed 3A 24V DC

Power Controllers

Regarding UL standard, product is certified by UL, but can also be certified by CSA in some cases. Check information for CSA certification as well.
Relays CSA Certification
See category for classification of UL Standard and CSA Standard.
Category for classification of UL Standard
Model Ratings Standard No. File No. Category Listed/Recognized Output Ratings
G32A-EA-US UL508 E64562 NMFT8 Recognized 15mA 12V DC
G3PW-220EU-C UL508 NMFT2, NMFT8 Recognized 20A 240V AC
G3PW-245EU-C UL508 NMFT2, NMFT8 Recognized 45A 240V AC
G3PW-260EU-C UL508 NMFT2, NMFT8 Recognized 60A 240V AC
G3PW-220EC-C-FLK UL508 NMFT2, NMFT8 Recognized 20A 240V AC
G3PW-245EC-C-FLK UL508 NMFT2, NMFT8 Recognized 45A 240V AC
G3PW-260EC-C-FLK UL508 NMFT2, NMFT8 Recognized 60A 240V AC
G3PW-220EU-S UL508 NMFT2, NMFT8 Recognized 20A 240V AC
G3PW-245EU-S UL508 NMFT2, NMFT8 Recognized 45A 240V AC
G3PW-260EU-S UL508 NMFT2, NMFT8 Recognized 60A 240V AC
G3PW-220EC-S-FLK UL508 NMFT2, NMFT8 Recognized 20A 240V AC
G3PW-245EC-S-FLK UL508 NMFT2, NMFT8 Recognized 45A 240V AC
G3PW-260EC-S-FLK UL508 NMFT2, NMFT8 Recognized 60A 240V AC
Model Ratings Standard No. File No. Category Listed/Recognized Input Ratings
G3ZA-4H203-FLK-UTU --- UL508 E95399 NRAQ/NRAQ7 Listed AC100~240V
G3ZA-4H403-FLK-UTU --- UL508 NRAQ/NRAQ7 Listed AC400~480V
G3ZA-8A203-FLK-UTU --- UL508 NRAQ/NRAQ7 Listed AC100~240V
G3ZA-8A403-FLK-UTU --- UL508 NRAQ/NRAQ7 Listed AC400~480V

Power Relays

Regarding UL standard, product is certified by UL, but can also be certified by CSA in some cases. Check information for CSA certification as well.
Relays CSA Certification
See category for classification of UL Standard and CSA Standard.
Category for classification of UL Standard
Model Ratings Standard No. File No. Category Listed/Recognized Contact Ratings
G7Z 12V DC
24V DC
UL508 E41643 NLDX2, NLDX8 Recognized NO contact:
40A 480V AC 60Hz(Resistive)
5A 120V DC(Resistive)
22A 480V AC 60Hz(General Use)
*D300(Carry current:1A)
NC contact:
25A 480V AC 60Hz(Resistive)
5A 120V DC(Resistive)
10A 480V AC 60Hz(General Use)
*D300(Carry current:1A)
G73Z ――― NLDX2, NLDX8 Recognized NO contact:
D300(Carry current:1A)
NC contact:
D300(Carry current:1A)
*Auxiliary contact ratings

Low Voltage Switchgear

Model Standard No. File No. Category Listed/Recognized
J7KC-12 UL60947-4-1 E41643 NLDX, NLDX7 Listed
J7KCA UL60947-5-1 E76675 NKCR, NKCR7 Listed
J7KCR UL60947-4-1 E41643 NLDX, NLDX7 Listed
J73KC-AM UL60947-5-1 E76675 NKCR2, NKCR8 Recognized
J76KC-RC UL60947-4-1 E41643 NLDX2, NLDX8 Recognized
J7MC-3P UL60947-4-1 E99424 NLRV, NLRV7 Listed
J7MC-3R UL60947-4-1 E99424 NLRV, NLRV7 Listed
J73MC UL60947-4-1 E99424 NLRV, NLRV7 Listed
J7TC UL60947-4-1 E76675 NKCR, NKCR7 Listed