K7GE-MG Insulation Resistance Monitoring Device/Sp...
...s Measurement range 0.1 to 99.9 MΩ (0.0 MΩ for less than 0.1 MΩ) Measuring accuracy ±5% rdg. ±1 digit (at ambient temperature -10 to 55°C and ambient humidity 25% to 65%) Megger voltage 50 VD...

https://www.ia.omron.com/products/family/3811/specification.html

K7TM Heater Condition Monitoring Device/Specificat...
... V AC: 0.0 to 660.0 V AC Measurement accuracy Absolute accuracy of voltage/current: ±0.5% FS ±1 digit to the input range Conditions: • When sine waves are input continuously • Variations in C...

https://www.ia.omron.com/products/family/3855/specification.html

E5CD-H Digital Temperature Controller (48 x 48 mm)...
... mounted separately) Thermocouple: (±0.1% of indication value or ±1°C, whichever is greater) ±1 digit max. *1 Platinum resistance thermometer: (±0.1% of indication value or ±0.5°C, whichever ...

https://www.ia.omron.com/products/family/3937/specification.html

E5ED-H Digital Temperature Controller (48 x 96 mm)...
...temperature of 23°C) Thermocouple: (±0.3% of indication value or ±1°C, whichever is greater) ±1 digit max. *1 Platinum resistance thermometer: (±0.2% of indication value or ±0.8°C, whichever ...

https://www.ia.omron.com/products/family/3938/specification.html

K3CV IO-Link AD Converter/Specifications | OMRON I...
...on Sampling rate Switchable between 50 ms (default) and 5 ms Influence of temperature ±1% FS ±1 digit or less Influence of voltage Installation influence Influence of EMS Instruction range K3...

https://www.ia.omron.com/products/family/3947/specification.html

K3MA-L Temperature Meter/Specifications | OMRON In...
...(at 23±5°C) (See note.) Thermocouple: (±0.5% of indication value or ±1°C, whichever greater) ±1 digit max. Platinum-resistance thermometer: (±0.5% of indication value or ±1°C, whichever great...

https://www.ia.omron.com/products/family/589/specification.html

explanation_of_terms.html
...t can be converted to a code that starts from address 0. (4)BCD Binary Coded Decimal Code. Each digit of a decimal number is expressed using a binary value. Serial Transmission In contrast to...

https://www.ia.omron.com/support/guide/34/explanation_of_terms.html

explanation_of_terms.html
... established by IEEE-USA. IEEE-796 Parity Check A parity bit is added to a data set as a binary digit to indicate whether the number of ones in a given set of bits is even or odd. It acts as ...

https://www.ia.omron.com/support/guide/62/explanation_of_terms.html

explanation_of_terms.html
... established by IEEE-USA. IEEE-796 Parity Check A parity bit is added to a data set as a binary digit to indicate whether the number of ones in a given set of bits is even or odd. It acts as ...

https://www.ia.omron.com/support/guide/63/explanation_of_terms.html

faq04288
...utput operation were added to weekly timers. Twin timer operation was added to the timers. An 8-digit counter and 8-digit comparators were added. The power supply voltage for CPU Uni...

https://www.ia.omron.com/support/faq/answer/66/faq04288/