PDFCSM_K3HB-S_DS_E_11_7 1 Linear Sensor Indicator K3H...
...urrent input 0 to 20 mA 0.000 to 20.000 mA−2.000 to 22.000 mA 120Ωmax. One input: ±0.1% F.S. ±1 digit max. Two inputs: ±0.2% F.S. ±1 digit max. ±31 mA 4 to 20 mA 4.000 to 20.000 mA 2...

https://www.ia.omron.com/data_pdf/cat/k3hb-s_ds_e_11_7_csm263.pdf

PDFCSM_K3HB-V_DS_E_11_7 1 Weighing Indicator K3HB-V
...stantaneous overload (30 s) K3HB-VLC Load Cell, mV A a lc 0.00 to 199.99 mV 1 MΩmin.±0.1% rdg±1 digit max.±200 V B b lc 0.000 to 19.999 mV±0.1% rdg±5 digits max. C c lc±100.00 mV±0.1% rdg±3 d...

https://www.ia.omron.com/data_pdf/cat/k3hb-v_ds_e_11_7_csm264.pdf

PDFCSM_K3HB-X_DS_E_12_7 1 Process Indicator K3HB-X
...ous overload (30 s) K3HB-XVD DC voltage A a vd±199.99 V -199.99 to 219.99 V 10 MΩmin.±0.1%rdg±1 digit max. ±400 V B b vd±19.999 V -19.999 to 21.999 V 1 MΩmin.±200 V C c vd±1.9999 V -1.9999 to...

https://www.ia.omron.com/data_pdf/cat/k3hb-x_ds_e_12_7_csm254.pdf

PDFCSM_K3MA-F_DS_E_14_4 1 Frequency/Rate Meter K3MA-F
... min. Must be able to dependably switch a load current of 5 mA max. Measuring accuracy±0.1%FS±1 digit (at 23±5°C) Measurement method Cycle measurement Max. displayed digits 5 digits (−19999 t...

https://www.ia.omron.com/data_pdf/cat/k3ma-f_ds_e_14_4_csm265.pdf

PDFCSM_K3MA-J_DS_E_13_5 1 Process Meter K3MA-J
...ange Measuring accuracy Input impedance Displayable range DC voltage 1.000 to 5.000 V±0.1% FS±1 digit max. (at 23±3°C) 1 MΩmin.–19999 to 99999 (with scaling function) 0.000 to 5.000 V –5.000 ...

https://www.ia.omron.com/data_pdf/cat/k3ma-j_ds_e_13_5_csm255.pdf

PDF1 CSM_K3MA-L_DS_E_11_4 Temperature Meter K3MA-L
... Note: The indication accuracy of the K thermocouple at a temperature of−200 to 1300°C is±2°C±1 digit maximum. The indication accuracy of the T and N thermocouples at a temperature of−100°C o...

https://www.ia.omron.com/data_pdf/cat/k3ma-l_ds_e_11_4_csm266.pdf

PDF1 Motor Condition Monitoring Device
... 0 to 999 Recommended frequency: 20 to 80 Hz *1 Measurement absolute accuracy Current±1.0% FS±1 digit (at 10 to 30°C, CT variation is not included) *2 Sampling cycle Degradation level/degrada...

https://www.ia.omron.com/data_pdf/cat/k6cm_n218-e1_3_1_csm1060693.pdf

PDF1 Motor Condition Monitoring Device K6CM-CI
... 0 to 999 Recommended frequency: 20 to 80 Hz *1 Measurement absolute accuracy Current±1.0% FS±1 digit (at 10 to 30°C, CT variation is not included) *2 Sampling cycle Degradation level 1, degr...

https://www.ia.omron.com/data_pdf/cat/k6cm_n218-e1_5_4_csm1060693.pdf

PDF1 Advanced Motor Condition Monitoring Device K7DD
...rameter. (H) Up Key Increases the set value for the displayed parameter. (I) Shift Key Used for digit shift in the set value of the displayed parameter. (J) Unit Number Setting Switch Sets th...

https://www.ia.omron.com/data_pdf/cat/k7dd_n234-e1_3_3_csm1124083.pdf

PDF1 Insulation Resistance Monitoring Device K7GE-MG
...tions Measurement range 0.1 to 99.9 MΩ(0.0 MΩfor less than 0.1 MΩ) Measuring accuracy±5% rdg.±1 digit (at ambient temperature -10 to 55°C and ambient humidity 25% to 65%) Megger voltage 50 VD...

https://www.ia.omron.com/data_pdf/cat/k7ge-mg_n225-e1_2_2_csm1106906.pdf