PDFCSM_K3HB-P_DS_E_17_1 1 Timer Interval Indicator K3...
...ltage Power consumption (See note 1.) 100 to 240 VAC: 18 VA max. (max. load) 24 VAC/DC: 11 VA/7 W max. (max. load) Input No-voltage contact, voltage pulse, open collector External power suppl...

https://www.ia.omron.com/data_pdf/cat/k3hb-p_ds_e_17_1.pdf

PDFCSM_K3HB-R_DS_E_17_1 1 Rotary Pulse Indicator K3HB...
...ltage Power consumption (See note 1.) 100 to 240 VAC: 18 VA max. (max. load) 24 VAC/DC: 11 VA/7 W max. (max. load) Input No-voltage contact, voltage pulse, open collector External power suppl...

https://www.ia.omron.com/data_pdf/cat/k3hb-r_ds_e_17_1.pdf

PDFCSM_K3HB-S_DS_E_12_1 1 Linear Sensor Indicator K3H...
...voltage Power consumption (See note 1.) 100 to 240 V: 18 VA max. (max. load) 24 VAC/DC: 11 VA/7 W max. (max. load) Input DC voltage/current A/D conversion method Delta-Sigma method External p...

https://www.ia.omron.com/data_pdf/cat/k3hb-s_ds_e_12_1.pdf

PDFCSM_K3HB-V_DS_E_12_1 1 Weighing Indicator K3HB-V
...voltage Power consumption (See note 1.) 100 to 240 V: 18 VA max. (max. load) 24 VAC/DC: 11 VA/7 W max. (max. load) Input DC voltage A/D conversion method Delta-Sigma method External power sup...

https://www.ia.omron.com/data_pdf/cat/k3hb-v_ds_e_12_1.pdf

PDFCSM_K3HB-X_DS_E_13_1 1 Process Indicator K3HB-X
...voltage Power consumption (See note 1.) 100 to 240 V: 18 VA max. (max. load) 24 VAC/DC: 11 VA/7 W max. (max. load) Input DC voltage, DC current, AC voltage, AC current A/D conversion method D...

https://www.ia.omron.com/data_pdf/cat/k3hb-x_ds_e_13_1.pdf

PDFCSM_K3MA-F_DS_E_14_4 1 Frequency/Rate Meter K3MA-F
... rated supply voltage Power consumption (under maximum load) 6 VA max. 4.5 VA max. (24 VAC) 4.5 W max. (24 VDC) External power supply 12 VDC (±10%), 0 to 40 mA Insulation resistance 20 MΩmin....

https://www.ia.omron.com/data_pdf/cat/k3ma-f_ds_e_14_4_csm265.pdf

PDFCSM_K3MA-J_DS_E_13_5 1 Process Meter K3MA-J
... rated supply voltage Power consumption (under maximum load) 6 VA max. 4.5 VA max. (24 VAC) 4.5 W max. (24 VDC) Insulation resistance 20 MΩmin. (at 500 VDC) between external terminal and case...

https://www.ia.omron.com/data_pdf/cat/k3ma-j_ds_e_13_5_csm255.pdf

PDF1 CSM_K3MA-L_DS_E_11_4 Temperature Meter K3MA-L
... rated supply voltage Power consumption (under maximum load) 6 VA max. 4.5 VA max. (24 VAC) 4.5 W max. (24 VDC) Insulation resistance 20 MΩmin. (at 500 VDC) between external terminal and case...

https://www.ia.omron.com/data_pdf/cat/k3ma-l_ds_e_11_4_csm266.pdf

PDF1 Motor Condition Monitoring Device K6CM-CI
...ly voltage Power supply frequency range 45 to 65 Hz Power consumption 24 VAC/24 VDC: 3.2 VA/1.7 W max. 100 to 240 VAC: 6.1 VA max. Input Current, comprehensive current diagnosis (CT) Rated in...

https://www.ia.omron.com/data_pdf/cat/k6cm_n218-e1_5_4_csm1060693.pdf

PDF1 Thermal condition monitoring device K6PM-TH
... 85% to 110% of the power supply voltage Power supply frequency range --- Power consumption 1.6 W max. Input Compatible sensor K6PM-THS3232 Number of connected K6PM sensors 31 units Output Ou...

https://www.ia.omron.com/data_pdf/cat/k6pm_h232-e1_2_3_csm1072127.pdf