K3HB-HTA-L1AC1 AC/DC24 | OMRON Industrial Automati...
...c strength Between the entire external terminal and case: 2,300 VAC 1 min Noise immunity ±1,500 V at power supply terminals in normal or common mode (waveform with 1-ns rising edge and pulse ...

https://www.ia.omron.com/product/item/65148/

K3HB-RNB-A1 AC100-240 | OMRON Industrial Automatio...
...t voltage pulse 50 kHz max. ON/OFF pulse width of 9 µs min. Voltage level ON voltage: 4.5 to 30 V, OFF voltage: -30 to 2 V, input impedance: 10 kΩ Open collector 50 kHz max. ON/OFF p...

https://www.ia.omron.com/product/item/65151/

K3HB-RNB-AC1 AC/DC24 | OMRON Industrial Automation
...t voltage pulse 50 kHz max. ON/OFF pulse width of 9 µs min. Voltage level ON voltage: 4.5 to 30 V, OFF voltage: -30 to 2 V, input impedance: 10 kΩ Open collector 50 kHz max. ON/OFF p...

https://www.ia.omron.com/product/item/65152/

K3HB-RNB-AC21 AC/DC24 | OMRON Industrial Automatio...
...t voltage pulse 50 kHz max. ON/OFF pulse width of 9 µs min. Voltage level ON voltage: 4.5 to 30 V, OFF voltage: -30 to 2 V, input impedance: 10 kΩ Open collector 50 kHz max. ON/OFF p...

https://www.ia.omron.com/product/item/65153/

K3HB-RNB-AT12 AC100-240 | OMRON Industrial Automat...
...t voltage pulse 50 kHz max. ON/OFF pulse width of 9 µs min. Voltage level ON voltage: 4.5 to 30 V, OFF voltage: -30 to 2 V, input impedance: 10 kΩ Open collector 50 kHz max. ON/OFF p...

https://www.ia.omron.com/product/item/65154/

K3HB-RNB-AT21 AC/DC24 | OMRON Industrial Automatio...
...t voltage pulse 50 kHz max. ON/OFF pulse width of 9 µs min. Voltage level ON voltage: 4.5 to 30 V, OFF voltage: -30 to 2 V, input impedance: 10 kΩ Open collector 50 kHz max. ON/OFF p...

https://www.ia.omron.com/product/item/65155/

K3HB-RNB-CPAC1 AC100-240 | OMRON Industrial Automa...
...t voltage pulse 50 kHz max. ON/OFF pulse width of 9 µs min. Voltage level ON voltage: 4.5 to 30 V, OFF voltage: -30 to 2 V, input impedance: 10 kΩ Open collector 50 kHz max. ON/OFF p...

https://www.ia.omron.com/product/item/65156/

K3HB-SSD-C1 AC/DC24 | OMRON Industrial Automation
.... Max. permissible input ±31 mA Voltage measurement input Measurement range 0-5: 0.000 to 5.000 V 1-5: 1.000 to 5.000 V 5: ±5.000 V 10: ±10.000 V Indication range 0...

https://www.ia.omron.com/product/item/65170/

K3HB-SSD-C11 AC100-240 | OMRON Industrial Automati...
.... Max. permissible input ±31 mA Voltage measurement input Measurement range 0-5: 0.000 to 5.000 V 1-5: 1.000 to 5.000 V 5: ±5.000 V 10: ±10.000 V Indication range 0...

https://www.ia.omron.com/product/item/65171/

K3HB-SSD-C2 AC100-240 | OMRON Industrial Automatio...
.... Max. permissible input ±31 mA Voltage measurement input Measurement range 0-5: 0.000 to 5.000 V 1-5: 1.000 to 5.000 V 5: ±5.000 V 10: ±10.000 V Indication range 0...

https://www.ia.omron.com/product/item/65172/