Primary Contents

Site Search Results

Site Search Product Search IA Global Search
Results 1621 - 1630 of 1716
PDFIO-Link Products IO-Link Series
...r IO-Link I/O Hub Controller IO-Link master IO-Link Converter AD converter Analog current input K thermocouple input Resistance temperature detector input K3CV P.40 24 Applicable fluid *1 Rat...

https://www.ia.omron.com/data_pdf/cat/io-link_series_y229-e1_11_1_csm1053004.pdf

PDF1 Magnetic Contactor J7KC Series
...C J76KC-RC-3 24-48 VAC Yes J76KC-RC-N-1 48-125 VAC J76KC-RC-N-2 Model Minimum order (bag) J77KC-K 1 (30 pcs./bag) Model J78KC J7KC Series 5 Ratings/Specifications The ratings/specifications a...

https://www.ia.omron.com/data_pdf/cat/j7kc_j230-e1_9_1_csm1074607.pdf

PDF1 Auxiliary Relay (Contactor Relay) J7KCA Series
...C J76KC-RC-3 24-48 VAC Yes J76KC-RC-N-1 48-125 VAC J76KC-RC-N-2 Model Minimum order (bag) J77KC-K 1 (30 pcs./bag) Coil rating Contact configuration Model J7KCA Series 4 Ratings/Specifications...

https://www.ia.omron.com/data_pdf/cat/j7kca_j232-e1_6_1_csm1074609.pdf

PDF1 Manual Motor Starter (Motor Protection Circuit B...
...0 Model Auxiliary contact J73MC-W-10 SPST-1NO J73MC-W-01 SPST-1NC Model Auxiliary contact J73MC-K-10 SPST-1NO J73MC-K-01 SPST-1NC Model Minimum order (bag) For main unit J77MC-A 1 (1...

https://www.ia.omron.com/data_pdf/cat/j7mc_j233-e1_5_1_csm1074610.pdf

PDF1 Thermal overload relay J7TC Series
...10 9-13 A J7TC-01-13 Model Minimum order (bag) J77KC-T (for main circuit) 1 (30 pcs./bag) J77KC-K (for auxiliary circuit) Model J78KC 3-phase standard motor capacity and full load current (re...

https://www.ia.omron.com/data_pdf/cat/j7tc_j231-e1_7_1_csm1074608.pdf

PDFK3CV series IO-Link AD Converter
...3 Analog voltage 0 to 10V K3CV-1ADVA-IL3 Analog voltage -10 to 10V K3CV-1ADVB-IL3 Thermocouples K thermocouple -20.0 to 500.0℃K3CV-1TCKA-IL3 Resistance temperature detector Resistance tempera...

https://www.ia.omron.com/data_pdf/cat/k3cv_h242-e1_2_1_csm1132257.pdf

PDF1 IO-Link AD Converter K3CV Analog signals are con...
...20 mA IB Analog current 0 to 20 mA VA Analog voltage 0 to 10 V VB Analog voltage -10 to 10 V KA K Thermocouple -20.0 to 500.0°C PA Resistance temperature detector: -200.0 to 500.0°C IL3 IO-Li...

https://www.ia.omron.com/data_pdf/cat/k3cv_h243-e1_2_1_csm1132260.pdf

PDFCSM_K3GN_DS_E_7_2 1 1/32 DIN Digital Panel Meter K...
...ons terminals. Linear output 0 to 20 mA DC, 4 to 20 mA DC 0 to 5 VDC, 1 to 5 VDC, 0 to 10 VDC I,K-L Outputs Outputs relay or transistor outputs. There is also a PASS output for models with tr...

https://www.ia.omron.com/data_pdf/cat/k3gn_ds_e_7_2_csm253.pdf

PDFCSM_K3HB-H_DS_E_14_6 1 Temperature Indicator K3HB-...
...et power supply: 50 mA max. (24 VDC) Input Platinum-resistance thermometer: Pt100 Thermocouple: K, J, T, E, L, U, N, R, S, B, W A/D conversion method Delta-Sigma method External power supply ...

https://www.ia.omron.com/data_pdf/cat/k3hb-h_ds_e_14_6_csm260.pdf

PDFCSM_K3HB-S_DS_E_11_6 1 Linear Sensor Indicator K3H...
...be set to 4 to 20 mA and the other can be set to 1 to 5 V. •In addition to calculations such as K (constant)–A (input for one cir- cuit), it is possible to perform calculations based on the i...

https://www.ia.omron.com/data_pdf/cat/k3hb-s_ds_e_11_6_csm263.pdf

Results 1621 - 1630 of 1716