Primary Contents

Site Search Results

Site Search Product Search
Results 171 - 180 of 251
PDFProgrammable Controllers
...) •Mnemonics Instruction length 1 to 7 steps per instruction Ladder instructions Approx. 400 (3-digit function codes) Execution time Basic instructions 0.02μs min. Special instructions 0.04μs...

https://www.ia.omron.com/data_pdf/cat/cs1g_cs1h_cs1w_cs1d_p047-e1_14_16_csm1004120.pdf

PDFCSM_CS1W-CLK_DS_E_5_11 1 SYSMAC CS-series Controll...
.... Unit Number Switch One rotary switch. The unit number of the Unit on the PLC is set in single-digit hexadecimal. Node Address Switches Two rotary switches. The node address of the Unit on t...

https://www.ia.omron.com/data_pdf/cat/cs1w-clk_ds_e_5_11_csm1613.pdf

PDF1 CSM_CS1W-EIP21_EIP21S_DS_E_7_10
...ber setting switch This rotary switch sets the unit number on the CPU Unit with one hexadecimal digit. Node address setting switches These two rotary switches set the node address for the Eth...

https://www.ia.omron.com/data_pdf/cat/cs1w-eip21_eip21s_ds_e_7_10_csm1782.pdf

PDFCSM_CS1W-FLN22_DS_E_1_3 1 SYSMAC CS-series FL-net ...
...cators Display the operating status of the Unit. Unit Number Switch Sets the unit number in one digit hexadecimal. Node Number Switches Set the Unit's FINS node number in two digits hexadecim...

https://www.ia.omron.com/data_pdf/cat/cs1w-fln22_ds_e_1_3_csm2178.pdf

PDFCSM_CS1W-PROCESS_DS_E_2_3 1 CS-series Process Anal...
.... Accuracy (25°C) (See note.) With Celsius selected:±0.3% of PV or±1°C, whichever is greater,±1 digit max. With fahrenheit selected:±0.3% of PV or±2°F, whichever is greater,±1 digit ...

https://www.ia.omron.com/data_pdf/cat/cs1w-process_ds_e_2_3_csm1971.pdf

PDFMulti-vendor Network
...s to all 4 inputs. Indicator accuracy (±0.3% of indication value or±1°C, whichever is larger)±1 digit max. *2 -200 to 850°C input range: (±0.3% of indication value or±0.8°C, whichever is larg...

https://www.ia.omron.com/data_pdf/cat/drt2_devicenet_q102-e1_20_40.pdf

PDFBest Selection Start with Smart!
...2. External Input is " ". (b) Eco function Standby •Display goes off (the segment of the fourth digit of the threshold value lights in sequence) •Emission stops •Output turns OFF (for both L-...

https://www.ia.omron.com/data_pdf/cat/e32_e3nx-fa_e3nw_e418-e1_20_7_csm1002396.pdf

PDFEasy-to-read, simple and dependable Program contro...
...t temperature of 23°C) Thermocouple: (±0.3% of indication value or±1°C, whichever is greater)±1 digit max. Platinum resistance thermometer: (±0.2% of indication value or±0.8°C, whichever is g...

https://www.ia.omron.com/data_pdf/cat/e5_c-t_h187-e1_1_3_csm1018751.pdf

PDF1 Digital Temperature Controller
...tput (for driving SSR) •Linear current output Auxiliary Outputs •None •1 Dual displays: PV/SV 4-digit displays •PF (shift) Key •Temperature status display •Simple programming •Changed paramet...

https://www.ia.omron.com/data_pdf/cat/e5_c_e5_c-t_h177-e1_14_17_csm1001508.pdf

PDFDigital Temperature Controllers
...Digital Temperature Controllers E5C Series Life Size E5CC Just press the shift key to move the digit. Process Value/ Set Point RUN/STOP Alarm Value 1 Alarm Value 2 Alarm Value 1 Proportional...

https://www.ia.omron.com/data_pdf/cat/e5_c_h220-e1_3_1_csm1050129.pdf

Results 171 - 180 of 251