...l individually. (1) Wide operating voltage range(f.e.5VDC to 24VDC) (2) The operation indicator light is built-in (3) Output switching capacity has the direct connection with the Programmable...
...(V CC − V F )/R 1 = (5 − 1.2)/220 = 17 mA. (Formula 1) For the EE-SX1041, the standard value of light current I L = 0.5 to 14 mA (when I F = 20 mA). If I L is found using proportional calcula...
...the emitter is negative on condition that the illumination of the Photomicrosensor is 0 lx. I L Light current The collector current of a phototransistor under a specified input current condit...
...he following table shows the sensing method and characteristics for modulated and non-modulated light. Non-modulated Modulated Sensing method Method used to detect light steadily emi...
...nts FAQ No. FAQ01171 Related Contents Primary Contents Question Are Photomicro Sensors with the Light-ON/Dark-ON selectable operating mode available? Answer Yes. The EE-SX67[] Series for Th...
...sensors Used for Industrial Equipment? Answer The response time is the delay between when the light input is interrupted and when the control output operates or is released. Generally, the ...
...ntents Primary Contents Question Can Photomicrosensors be used on locations subject to external light interference? Answer Install the Sensors in a location and using methods to ensure that...
...61 Related Contents Primary Contents Question Can Photomicro Sensors be used with a Slit on the light emitting/receiving window? Answer No, it is not possible to use Photomicro Sensors with...
...Sensors: Approx. 0.025 to 0.05 mm (If the sensing object travels across the shorter side of the light emitting/receiving window.) Reflective Photomicro Sensors: Approx. 0.2 to 0.5 mm (If the ...
...P Photomicro Sensors cable? Answer EE-SP Series uses an LED for pulse illumination (modulated light). A circuit to fully stabilize the power supply voltage is not built into the Sensors, an...