MY4H DC48 | OMRON Industrial Automation
...se voltage (Reset voltage) 10 % min. Maximum voltage 110 % (23 ℃) Power consumption Approx. 0.9 W Contact Contact rated load 110 VAC 3 A (Resistive load) 110 VAC 0.8 A (Inductive load (cosφ =...

https://www.ia.omron.com/product/item/35418/

MY4H-0 AC110/120 | OMRON Industrial Automation
... DC: 3 A Maximum switching power 330 VA (Resistive load) 88 VA (Inductive load (cosφ = 0.4)) 72 W (Resistive load) 36 W (Inductive load (L/R = 7 ms)) Contact form 4PDT Contact method...

https://www.ia.omron.com/product/item/35419/

MY4H-0 DC24 | OMRON Industrial Automation
...se voltage (Reset voltage) 10 % min. Maximum voltage 110 % (23 ℃) Power consumption Approx. 0.9 W Contact Contact rated load 110 VAC 3 A (Resistive load) 110 VAC 0.8 A (Inductive load (cosφ =...

https://www.ia.omron.com/product/item/35420/

MY4IN-CR AC200/220 (S) | OMRON Industrial Automati...
...: 5 A Maximum switching power 1250 VA (Resistive load) 200 VA (Inductive load (cosφ = 0.4)) 150 W (Resistive load) 45 W (Inductive load (L/R = 7 ms)) Contact form 4PDT Contact method...

https://www.ia.omron.com/product/item/35423/

MY4IN-D2 DC48 (S) | OMRON Industrial Automation
...se voltage (Reset voltage) 10 % min. Maximum voltage 110 % (23 ℃) Power consumption Approx. 0.9 W Contact Contact rated load 250 VAC 3 A (Resistive load) 250 VAC 0.8 A (Inductive load (cosφ =...

https://www.ia.omron.com/product/item/35424/

MY4ZH-0 DC100/110 | OMRON Industrial Automation
...se voltage (Reset voltage) 10 % min. Maximum voltage 110 % (23 ℃) Power consumption Approx. 0.9 W Contact Contact rated load 110 VAC 3 A (Resistive load) 110 VAC 0.8 A (Inductive load (cosφ =...

https://www.ia.omron.com/product/item/35447/

MY4ZH-0 DC24 | OMRON Industrial Automation
...se voltage (Reset voltage) 10 % min. Maximum voltage 110 % (23 ℃) Power consumption Approx. 0.9 W Contact Contact rated load 110 VAC 3 A (Resistive load) 110 VAC 0.8 A (Inductive load (cosφ =...

https://www.ia.omron.com/product/item/35449/

MY4ZIN-CR AC100/110 (S) | OMRON Industrial Automat...
...: 5 A Maximum switching power 1250 VA (Resistive load) 200 VA (Inductive load (cosφ = 0.4)) 150 W (Resistive load) 45 W (Inductive load (L/R = 7 ms)) Contact form 4PDT Contact method...

https://www.ia.omron.com/product/item/35451/

MY4ZIN-CR AC200/220 (S) | OMRON Industrial Automat...
...: 5 A Maximum switching power 1250 VA (Resistive load) 200 VA (Inductive load (cosφ = 0.4)) 150 W (Resistive load) 45 W (Inductive load (L/R = 7 ms)) Contact form 4PDT Contact method...

https://www.ia.omron.com/product/item/35452/

MY4ZIN-D2 DC12 (S) | OMRON Industrial Automation
...se voltage (Reset voltage) 10 % min. Maximum voltage 110 % (23 ℃) Power consumption Approx. 0.9 W Contact Contact rated load 250 VAC 3 A (Resistive load) 250 VAC 0.8 A (Inductive load (cosφ =...

https://www.ia.omron.com/product/item/35453/