LY Bi-power Relays/Specifications | OMRON Industri...
...larity 1,000 VAC at 50/60 Hz for 1 min. Vibration resistance Destruction 10 to 55 to 10 Hz, 0.5-mm single amplitude (1.0-mm double amplitude) Malfunction 10 to 55 to 10 Hz, 0.5-...

https://www.ia.omron.com/products/family/949/specification.html

Further Information of Solid-state Relays | OMRON ...
...surement position. If there is a duct or other equipment within the measurement distance of 100 mm, refer to Figure 2. If the side temperature cannot be measured, refer to Figure 3. (3)If mor...

https://www.ia.omron.com/support/guide/18/further_information.html

Further Information of Level Switches | OMRON Indu...
...evel Controller is 30 kΩ·cm when using a PS-3S Electrode Holder within a submersion depth of 30 mm. For any fluid with specific resistance higher than this value, use a high-sensitivity Level...

https://www.ia.omron.com/support/guide/33/further_information.html

PDFSensors Switches Safety Components Relays Control ...
...20 With the standard heat sink (Y92B-A100 or Y92B-N50) or an aluminum plate measuring 75×75×3.2 mm (W×H×t) No heat sink Load current (A) Ambient temperature (°C) Technical Explanation for Sol...

https://www.ia.omron.com/data_pdf/guide/18/ssr_tg_e_9_12.pdf

PDFSensors Switches Safety Components Relays Control ...
... by the Power Supply itself. Note: As a general rule, the ambient temperature is measured at 50 mm below the Power Supply. (There are exceptions for some models.) Storage Temperature The allo...

https://www.ia.omron.com/data_pdf/guide/22/powersupply_tg_e_8_4.pdf

PDFSensors Switches Safety Components Relays Control ...
...ons (6) Contact Shape and Type (7) Contact Gap The contact gap is either 0.25, 0.5, 1.0, or 1.8 mm. The contact gap is a design goal. Check the contact gap of the switch to be used if a minim...

https://www.ia.omron.com/data_pdf/guide/29/microswitch_tg_e_3_4.pdf

PDFSensors Switches Safety Components Relays Control ...
...vel Controller is 30 kΩ·cm when using a PS- 3S Electrode Holder within a submersion depth of 30 mm. For any fluid with specific resistance higher than this value, use a high-sensitivity Level...

https://www.ia.omron.com/data_pdf/guide/33/levelapparatus_tg_e_8_2.pdf

PDFSensors Switches Safety Components Relays Control ...
...g Relays, etc Relays with 1 to 4 poles are mainly used for relay sequences or I/O applications. MM(K), MK(S), MY, LY, G2R(S), G2RV, G7T, etc. Built-in relays •High -capacity Relays, etc. Buil...

https://www.ia.omron.com/data_pdf/guide/36/generalrelay_tg_e_10_7.pdf

Further Information of Programmable Controllers Te...
...ystem, so approx. 10- 20% extra space should be allowed for this. (5)Where necessary, about 600 mm of space should be kept behind the panel for the purpose of performing maintenance. PLC Cont...

https://www.ia.omron.com/support/guide/26/further_information.html

PDFSensors Switches Safety Components Relays Control ...
...ler with a low command pulse frequency or to set the machine travel distance per pulse, to 0.01 mm for example. Torque Limit A function that limits the output torque of a motor. The torque li...

https://www.ia.omron.com/data_pdf/guide/14/servo_tg_e_2_1.pdf