Primary Contents

Site Search Results

Site Search Product Search IA Global Search
Results 3341 - 3350 of 4815
MM2XP DC125 | OMRON Industrial Automation
.... Release voltage (Reset voltage) 10 % min. Maximum voltage 110 % Power consumption Approx. 2.1 W Contact Contact rated load 110 VDC 7 A (Resistive load) 110 VDC 6 A (Inductive load (L/R = 7 ...

https://www.ia.omron.com/product/item/6992/

MM2XP DC6 | OMRON Industrial Automation
.... Release voltage (Reset voltage) 10 % min. Maximum voltage 110 % Power consumption Approx. 2.1 W Contact Contact rated load 110 VDC 7 A (Resistive load) 110 VDC 6 A (Inductive load (L/R = 7 ...

https://www.ia.omron.com/product/item/6996/

MM2XP-D DC12 | OMRON Industrial Automation
.... Release voltage (Reset voltage) 10 % min. Maximum voltage 110 % Power consumption Approx. 2.1 W Contact Contact rated load 110 VDC 7 A (Resistive load) 110 VDC 6 A (Inductive load (L/R = 7 ...

https://www.ia.omron.com/product/item/6998/

MM2XP-D DC125 | OMRON Industrial Automation
.... Release voltage (Reset voltage) 10 % min. Maximum voltage 110 % Power consumption Approx. 2.1 W Contact Contact rated load 110 VDC 7 A (Resistive load) 110 VDC 6 A (Inductive load (L/R = 7 ...

https://www.ia.omron.com/product/item/6999/

E3JK-RR11 2M | OMRON Industrial Automation
... voltage 24 to 240 VAC±10% 50/60 Hz 24 to 240 VDC±10% ripple (p-p) 10% max. Power consumption 2 W max. Control output Relay output (SPDT) 250 VAC 3 A (cosφ= 1) max. 5 VDC 10 mA min. Life expe...

https://www.ia.omron.com/product/item/70/

MM2XPN AC100/(110) | OMRON Industrial Automation
...tage 250 VAC 250 VDC Max. contact current AC: 7.5 A DC: 7.5 A Maximum switching power 20 VA 800 W (Resistive load) 660 W (Inductive load (L/R = 7 ms)) Contact form DPDT Contact metho...

https://www.ia.omron.com/product/item/7003/

MM2XPN DC100/110 | OMRON Industrial Automation
.... Release voltage (Reset voltage) 10 % min. Maximum voltage 110 % Power consumption Approx. 2.1 W Contact Contact rated load 110 VDC 7 A (Resistive load) 110 VDC 6 A (Inductive load (L/R = 7 ...

https://www.ia.omron.com/product/item/7005/

MM2XPN DC12 | OMRON Industrial Automation
.... Release voltage (Reset voltage) 10 % min. Maximum voltage 110 % Power consumption Approx. 2.1 W Contact Contact rated load 110 VDC 7 A (Resistive load) 110 VDC 6 A (Inductive load (L/R = 7 ...

https://www.ia.omron.com/product/item/7006/

MM2XPN DC200/220 | OMRON Industrial Automation
.... Release voltage (Reset voltage) 10 % min. Maximum voltage 110 % Power consumption Approx. 2.1 W Contact Contact rated load 110 VDC 7 A (Resistive load) 110 VDC 6 A (Inductive load (L/R = 7 ...

https://www.ia.omron.com/product/item/7008/

MM2XPN DC48 | OMRON Industrial Automation
.... Release voltage (Reset voltage) 10 % min. Maximum voltage 110 % Power consumption Approx. 2.1 W Contact Contact rated load 110 VDC 7 A (Resistive load) 110 VDC 6 A (Inductive load (L/R = 7 ...

https://www.ia.omron.com/product/item/7010/

Results 3341 - 3350 of 4815