PDFCSM_CS1W-CLK_DS_E_5_11 1 SYSMAC CS-series Controll...
...minals to connect to the Controller Link Network communications cable (twisted-pair cable). 6.2 mm max. 6.2 mm max. 10 CS1W-CLK CS1W-CLK13/CS1W-CLK12-V1 * *Discontinuation models in ...

https://www.ia.omron.com/data_pdf/cat/cs1w-clk_ds_e_5_11_csm1613.pdf

PDFCSM_CS1W-CRM21_DS_E_9_5 1 CS-series CompoNet Maste...
... (applied to PLC power supply). Vibration resistance 10 to 61.2 Hz with single-amplitude of 0.1 mm, 61.2 to 150 Hz and 14.7 m/s2 in X, Y, and Z directions for 80 min each (sweep time of 8 min...

https://www.ia.omron.com/data_pdf/cat/cs1w-crm21_ds_e_9_5_csm1636.pdf

PDF1 CSM_CS1W-EIP21_EIP21S_DS_E_7_10
...0 mA max. at 5 V DC Weight CS1W-EIP21: 171 g max. CS1W-EIP21S: 180 g max. Dimensions 35×130×101 mm (W×H×D) Other general specifications Other specifications conform to the general specificati...

https://www.ia.omron.com/data_pdf/cat/cs1w-eip21_eip21s_ds_e_7_10_csm1782.pdf

PDFCSM_CS1W-FLN22_DS_E_1_3 1 SYSMAC CS-series FL-net ...
...ption (Unit) 380 mA max. at 5 VDC Vibration resistance Conforms to JIS 0040. 10 to 57 Hz, 0.075-mm amplitude, 57 to 150 Hz, acceleration: 9.8 m/s2 in X, Y, and Z directions for 80 minutes eac...

https://www.ia.omron.com/data_pdf/cat/cs1w-fln22_ds_e_1_3_csm2178.pdf

PDFCSM_CS1W-PROCESS_DS_E_2_3 1 CS-series Process Anal...
... CS-series Special I/O Unit Structure Backplane-mounted, single slot size Dimensions 35×130×126 mm (W×H×D) Weight 450 g max. External connection terminals •CS1W-PTS55/-PTS56/-PDC55 24-point r...

https://www.ia.omron.com/data_pdf/cat/cs1w-process_ds_e_2_3_csm1971.pdf

PDFCS/CJ-series High-speed Data Storage Units
...(unit version 1.2 or later). CSV files Record contents Indices (record number), time stamps (hh:mm:ss:ms), ns, sampling indices (serial numbers starting at 0 when sampling is started), data f...

https://www.ia.omron.com/data_pdf/cat/cs1w-spu_cj1w-spu_v301-e1_3_1_csm1015430.pdf

PDF1 Non-Contact Safety Door Switch D40A-2
...w level coded (EN ISO 14119) Assured operating and release distance Operating distance OFF→ON 5 mm min. *1 Operating distance ON→OFF 15 mm max. *1 Differential travel 2.5 mm...

https://www.ia.omron.com/data_pdf/cat/d40a-2_f133-e1_2_2_csm1129085.pdf

PDFIABカタログ・マニュアル表4パターン(英文) _IAB基本(カタログテクニカルガイド用)
... door switches tailored to meet the diverse requirements of global equipment specifications. 25 mm 17 mm 13 mm Mounting holes: Two, 4.2 mm dia. Mounting pitch:...

https://www.ia.omron.com/data_pdf/cat/d40a-2_f134-e1_2_2_csm1129087.pdf

PDF1 Compact Non-Contact Door Switch/Non-Contact Door...
...g level Low level coded (EN ISO 14119) Operating characteristics *2 Operating distance OFF→ON 5 mm min. *1 Operating distance ON→OFF 15 mm max. *1 Differential travel 20% or less of ...

https://www.ia.omron.com/data_pdf/cat/d40a_g9sx-ns_c140-e1_10_7_csm1815.pdf

PDFCSM_D4A-_N_DS_E_4_7 1 General-purpose Limit Switch...
... DPDT, double-break: for 125 VAC, 5 A resistive load: 750,000 operations min. Operating speed 1 mm/s to 2 m/s (in case of D4A-3101N roller lever model) Operating frequency Mechanical: 300 ope...

https://www.ia.omron.com/data_pdf/cat/d4a-_n_ds_e_4_7_csm584.pdf

Results 3351 - 3360 of 3883