Primary Contents

Site Search Results

Site Search Product Search IA Global Search
Results 3661 - 3670 of 6516
E6A2-CS3E 500P/R 0.5M | OMRON Industrial Automatio...
... Output type Voltage output Output resistance 2 kΩ Load current 20 mA max. Residual voltage 0.4 V max. (Load current: at 20 mA max.) Max. response frequency 30 kHz Output duty factor 50±25% R...

https://www.ia.omron.com/product/item/2327/

E6A2-CS3E 60P/R 0.5M | OMRON Industrial Automation
... Output type Voltage output Output resistance 2 kΩ Load current 20 mA max. Residual voltage 0.4 V max. (Load current: at 20 mA max.) Max. response frequency 30 kHz Output duty factor 50±25% R...

https://www.ia.omron.com/product/item/2328/

E6A2-CS3E 60P/R 2M | OMRON Industrial Automation
... Output type Voltage output Output resistance 2 kΩ Load current 20 mA max. Residual voltage 0.4 V max. (Load current: at 20 mA max.) Max. response frequency 30 kHz Output duty factor 50±25% S...

https://www.ia.omron.com/product/item/2329/

E6A2-CS5C 100P/R 0.5M | OMRON Industrial Automatio...
... ms) Output phases A Control output Output type NPN open collector Load power supply voltage 30 V max.DC Sink current 30 mA max. Residual voltage 0.4 V max. (at sink current 30 mA) M...

https://www.ia.omron.com/product/item/2330/

E6A2-CS5C 100P/R 2M | OMRON Industrial Automation
... ms) Output phases A Control output Output type NPN open collector Load power supply voltage 30 V max.DC Sink current 30 mA max. Residual voltage 0.4 V max. (at sink current 30 mA) M...

https://www.ia.omron.com/product/item/2331/

E6A2-CS5C 10P/R 0.5M | OMRON Industrial Automation
... ms) Output phases A Control output Output type NPN open collector Load power supply voltage 30 V max.DC Sink current 30 mA max. Residual voltage 0.4 V max. (at sink current 30 mA) M...

https://www.ia.omron.com/product/item/2332/

E6A2-CS5C 10P/R 2M | OMRON Industrial Automation
... ms) Output phases A Control output Output type NPN open collector Load power supply voltage 30 V max.DC Sink current 30 mA max. Residual voltage 0.4 V max. (at sink current 30 mA) M...

https://www.ia.omron.com/product/item/2333/

E6A2-CS5C 200P/R 0.5M | OMRON Industrial Automatio...
... ms) Output phases A Control output Output type NPN open collector Load power supply voltage 30 V max.DC Sink current 30 mA max. Residual voltage 0.4 V max. (at sink current 30 mA) M...

https://www.ia.omron.com/product/item/2334/

E6A2-CS5C 200P/R 2M | OMRON Industrial Automation
... ms) Output phases A Control output Output type NPN open collector Load power supply voltage 30 V max.DC Sink current 30 mA max. Residual voltage 0.4 V max. (at sink current 30 mA) M...

https://www.ia.omron.com/product/item/2335/

E6A2-CS5C 300P/R 0.5M | OMRON Industrial Automatio...
... ms) Output phases A Control output Output type NPN open collector Load power supply voltage 30 V max.DC Sink current 30 mA max. Residual voltage 0.4 V max. (at sink current 30 mA) M...

https://www.ia.omron.com/product/item/2337/

Results 3661 - 3670 of 6516