MY4H AC110/120 | OMRON Industrial Automation
... DC: 3 A Maximum switching power 330 VA (Resistive load) 88 VA (Inductive load (cosφ = 0.4)) 72 W (Resistive load) 36 W (Inductive load (L/R = 7 ms)) Contact form 4PDT Contact method...

https://www.ia.omron.com/product/item/7477/

MY4H DC12 | OMRON Industrial Automation
...se voltage (Reset voltage) 10 % min. Maximum voltage 110 % (23 ℃) Power consumption Approx. 0.9 W Contact Contact rated load 110 VAC 3 A (Resistive load) 110 VAC 0.8 A (Inductive load (cosφ =...

https://www.ia.omron.com/product/item/7478/

MY4H DC24 | OMRON Industrial Automation
...se voltage (Reset voltage) 10 % min. Maximum voltage 110 % (23 ℃) Power consumption Approx. 0.9 W Contact Contact rated load 110 VAC 3 A (Resistive load) 110 VAC 0.8 A (Inductive load (cosφ =...

https://www.ia.omron.com/product/item/7480/

MY4IN DC12 (S) | OMRON Industrial Automation
...se voltage (Reset voltage) 10 % min. Maximum voltage 110 % (23 ℃) Power consumption Approx. 0.9 W Contact Contact rated load 250 VAC 3 A (Resistive load) 250 VAC 0.8 A (Inductive load (cosφ =...

https://www.ia.omron.com/product/item/7486/

MY4IN DC24 (S) | OMRON Industrial Automation
...se voltage (Reset voltage) 10 % min. Maximum voltage 110 % (23 ℃) Power consumption Approx. 0.9 W Contact Contact rated load 250 VAC 3 A (Resistive load) 250 VAC 0.8 A (Inductive load (cosφ =...

https://www.ia.omron.com/product/item/7487/

MY4IN DC48 (S) | OMRON Industrial Automation
...se voltage (Reset voltage) 10 % min. Maximum voltage 110 % (23 ℃) Power consumption Approx. 0.9 W Contact Contact rated load 250 VAC 3 A (Resistive load) 250 VAC 0.8 A (Inductive load (cosφ =...

https://www.ia.omron.com/product/item/7488/

MY4Z-02 DC24 | OMRON Industrial Automation
...se voltage (Reset voltage) 10 % min. Maximum voltage 110 % (23 ℃) Power consumption Approx. 0.9 W Contact Contact rated load 220 VAC 3 A (Resistive load) 220 VAC 0.8 A (Inductive load (cosφ =...

https://www.ia.omron.com/product/item/7536/

MY4Z-D DC24 | OMRON Industrial Automation
...se voltage (Reset voltage) 10 % min. Maximum voltage 110 % (23 ℃) Power consumption Approx. 0.9 W Contact Contact rated load 220 VAC 3 A (Resistive load) 220 VAC 0.8 A (Inductive load (cosφ =...

https://www.ia.omron.com/product/item/7549/

MY4ZH AC24 | OMRON Industrial Automation
... DC: 3 A Maximum switching power 330 VA (Resistive load) 88 VA (Inductive load (cosφ = 0.4)) 72 W (Resistive load) 36 W (Inductive load (L/R = 7 ms)) Contact form 4PDT Contact method...

https://www.ia.omron.com/product/item/7555/

MY4ZH DC24 | OMRON Industrial Automation
...se voltage (Reset voltage) 10 % min. Maximum voltage 110 % (23 ℃) Power consumption Approx. 0.9 W Contact Contact rated load 110 VAC 3 A (Resistive load) 110 VAC 0.8 A (Inductive load (cosφ =...

https://www.ia.omron.com/product/item/7559/