PDF1 Compact Non-Contact Door Switch/Non-Contact Door...
...tops. These Controllers make the most of D40A Switches. Two Different Controllers G9SX-NS @D40A input @Two instantaneous safety outputs @Logical AND connection output G9SX-NSA @D40A plus mech...

https://www.ia.omron.com/data_pdf/cat/d40a_g9sx-ns_c140-e1_10_6_csm1815.pdf

PDFAuthorized Distributor: In the interest of product...
...m D40Z-1C2 5 m D40Z-1C5 Safety outputs *1 Auxiliary monitoring output *3 Logical AND connection input Logical AND connection output OFF-delayed Max. OFF-delay time *4 Rated voltage Terminal b...

https://www.ia.omron.com/data_pdf/cat/d40z_c145-e1_8_4_csm2647.pdf

PDF1 Guard Lock Safety-door Switch/D4SL-N-mounting Sl...
... X1 14 24 T22 Auxiliary output Power supply circuit Safety Input1 Safety Input2 Reset/ Feedback Input Safety Output (Instant aneous) 64 63 22 21 34 33 S3 KM1 KM2 KM1 KM2 M S4 Lock release ena...

https://www.ia.omron.com/data_pdf/cat/d4sl-n_c146-e1_8_8_csm1004285.pdf

PDFMulti-vendor Network
...e) (DRT2-@D04CL(-1)/@D08CL(-1)/@D16CL(-1)) Analog I/O Terminals (DRT2-AD04(H)/DA02) Temperature Input Terminals (DRT2-TS04@) SmartSlice GRT1 Series SmartSlice GRT1 Series DeviceNet Communicat...

https://www.ia.omron.com/data_pdf/cat/drt2_devicenet_q102-e1_20_37_csm2147.pdf

PDFCSM_DST1 Series_DS_E_7_4 1 Safety I/O Terminals
... 100 mA 24 VDC 110 mA 24 VDC 100 mA 24 VDC 110 mA I/O power supply * 24 VDC 70 mA 24 VDC 50 mA (Input) 130 mA (Output) 24 VDC 80 mA (Input) 130 mA (Output) 24 VDC 50 mA (...

https://www.ia.omron.com/data_pdf/cat/dst1_series_ds_e_7_4_csm1275.pdf

PDF1 Standard Proximity Sensor E2E (DC 2/3-Wire)
...ty Sensor must satisfy the following. IOFF≥Ileak (If the OFF current is not listed in the PLC’s input specifications, take it to be 1.3 mA.) 3. The ON current of the PLC and the control outpu...

https://www.ia.omron.com/data_pdf/cat/e2e_d126-e1-01.pdf

PDFCSM_E2E_DS_E_13_6 1 Special Models E2E (E2E-X@D@-U...
...ty Sensor must satisfy the following. IOFF≥Ileak (If the OFF current is not listed in the PLC’s input specifications, take it to be 1.3 mA.) 3. The ON current of the PLC and the control outpu...

https://www.ia.omron.com/data_pdf/cat/e2e_ds_e_13_6_csm446.pdf

PDFCSM_E2EH_DS_E_6_4 1 Proximity Sensor Ideal for Hig...
...ty Sensor must satisfy the following. IOFF≥Ileak (If the OFF current is not listed in the PLC’s input specifications, take it to be 1.3 mA.) 3. The ON current of the PLC and the control outpu...

https://www.ia.omron.com/data_pdf/cat/e2eh_ds_e_6_4_csm672.pdf

PDF1 Smart Proximity Sensor E2NC Series
... required if you want to use the Amplifier Unit on a network. Type Appearance Connection method Input/output Model NPN output PNP output Advanced models Pre-wired (2 m) 2 outputs + 1 ...

https://www.ia.omron.com/data_pdf/cat/e2nc_e473-e1_7_1_csm1061200.pdf

PDF*This is the total adjustment time for the emitter...
...s, or 16 ms (Default: 250μs) 3,600 mm 0.03 mm dia. E3X-HD Series E3NX-FA Series Output External input Response time*3 Sensing distance (Giga-power mode) Minimum sensing object E32-LT35Z E32-L...

https://www.ia.omron.com/data_pdf/cat/e32-lt35z_e451-e1_1_2_csm1048853.pdf