Primary Contents

Site Search Results

Site Search Product Search IA Global Search
Results 4211 - 4220 of 4399
PDF1 Three-phase Voltage and Phase-sequence Phase-los...
...g LED indicator. Ordering Information List of Models Note: Three-phase 3-wire or 4-wire and the input range are switched using a DIP switch. * The power supply voltage is the same as the rate...

https://www.ia.omron.com/data_pdf/cat/k8ak-pm_n185-e1_3_7_csm1020915.pdf

PDF1 Three-phase Voltage Relay K8AK-PW
...dicator. Ordering Information List of Models Note: Three-phase, three-wire or four-wire and the input range are switched using a DIP switch. * The power supply voltage is the same as the rate...

https://www.ia.omron.com/data_pdf/cat/k8ak-pw_n184-e1_3_8_csm1020914.pdf

PDF1 Temperature Monitoring Relay K8AK-TH
...sign with a width of just 22.5 mm. •Rotary switches simplifies temperature settings. •Universal-input support for thermocouple or platinum resistance thermometer sensor input. •Chang...

https://www.ia.omron.com/data_pdf/cat/k8ak-th_n187-e1_4_7_csm1020917.pdf

PDF1 Thermistor Motor Protection Relay
...100 to 240 VAC Power consumption 24 VAC/DC: 1.8 VA/1.0 W max. 100 to 240 VAC: 3.5 VA max. Rated input voltage 3-phase, 200 to 480 VAC (3-wire) Operating time Phase sequence on three- phase vo...

https://www.ia.omron.com/data_pdf/cat/k8ak-ts_pt_n189-e1_3_7_csm1020919.pdf

PDF1 Single-phase Voltage Relay K8AK-VS
...een normally open and normally closed. •Process control signal (0 to 10 V) and current splitter input supported. •Output status can be monitored using LED indicator. •Input frequency...

https://www.ia.omron.com/data_pdf/cat/k8ak-vs_n181-e1_2_9_csm1020911.pdf

PDF1 Single-phase Overvoltage/Undervoltage Relay
...lays, 5 A at 250 VAC (resistive load). •Process control signal (0 to 10 V) and current splitter input supported. •Output status can be monitored using LED indicator. •Input frequency...

https://www.ia.omron.com/data_pdf/cat/k8ak-vw_n182-e1_2_8_csm1020912.pdf

PDF1 Three-phase Asymmetry and Phase-sequence Phase-l...
...elay status can be monitored using LED indicator. Ordering Information List of Models Note: The input range is set with a rotary switch. * The power supply voltage is the same as the rat...

https://www.ia.omron.com/data_pdf/cat/k8ds-pa_n193-e1_2_5_csm1020923.pdf

PDF1 Phase-sequence Phase-loss Relay
...motors. Ordering Information List of Models * The power supply voltage is the same as the rated input voltage. Refer to Safety Precautions on page 8. Refer to page 7 for commonly asked questi...

https://www.ia.omron.com/data_pdf/cat/k8ds-ph_n190-e1_2_4_csm1020920.pdf

PDF1 Three-phase Voltage and Phase-sequence Phase-los...
...elay status can be monitored using LED indicator. Ordering Information List of Models Note: The input range is set with a rotary switch. * The power supply voltage is the same as the rat...

https://www.ia.omron.com/data_pdf/cat/k8ds-pm_n192-e1_2_5_csm1020922.pdf

PDF1 Three-phase Undervoltage and Phase-sequence Phas...
...elay status can be monitored using LED indicator. Ordering Information List of Models Note: The input range is set with a rotary switch. * The power supply voltage is the same as the rat...

https://www.ia.omron.com/data_pdf/cat/k8ds-pu_n191-e1_2_6_csm1020921.pdf

Results 4211 - 4220 of 4399