Primary Contents

Site Search Results

Site Search Product Search
Results 5671 - 5680 of 6485
Safety Precautions of Push Buttons / Indicator Lam...
...han the CR impedance. C: 1 to 0.5 μF × switching current (A) R: 0.5 to 1 Ω × switching voltage (V) The values may change according to the characteristics of the load. The capacitor suppresses...

https://www.ia.omron.com/product/cautions/38/safety_precautions.html

Safety Precautions of Proximity Sensors Cautions f...
...re Common mode noise (inverter noise) (Common noise applied between the mounting board and the +V and 0-V lines, respectively.) Noise enters from the noise source through the frame (...

https://www.ia.omron.com/product/cautions/41/safety_precautions.html

Safety Precautions of Photoelectric Sensors Cautio...
...ure Common mode noise (inverter noise) Common noise applied between the mounting board and the +V and 0-V lines, respectively. Noise enters from the noise source through the frame (m...

https://www.ia.omron.com/product/cautions/43/safety_precautions.html

Safety Precautions of Digital Panel Indicators Cau...
...n Measurement Categories III, or IV (according to IEC 61010-1), and do not use the K3HB-S, K3HB-V, K3HBH, K3HB-R, K3HB-P, K3HB-C, K3MA-J, K3MA-L, K3MA-F, or K3GN for measurements within Measu...

https://www.ia.omron.com/product/cautions/62/safety_precautions.html

faq04288
...voltage range 10.8 to 28.8 VDC 20.4 to 26.4 VDC Input impedance 5.3 kΩ 5 kΩ 4.8 kΩ ON voltage 8 V 16 V Input commons Independent common terminal Internally connected to power supply ...

https://www.ia.omron.com/support/faq/answer/66/faq04288/

PDFPhotomicrosensors Technical Guide
...event mutual interference. Tr ON Tr OFF 0 1.0 2.0 3.0 4.0 5.0 6.0 Distance d (mm) d Tr OFF Tr 0/V 2.16 2.18 2.20 2.22 Distance d (mm) d d = 0.002mm± Vcc = 24V Number of repetitions: 20, Ta = ...

https://www.ia.omron.com/data_pdf/guide/24/photomicro_tg_e_4_1_5-6(engineering).pdf

PDFRotary Encoders Technical Guide
...00 200 1.4 1.2 1.0 0.8 0.6 0.4 0.2 0 VOL t LH Output rise time tLH (µs) Output residual voltage V OL (V) Cable length (m) Measurement Example Power supply voltage: 5 VDC Load resista...

https://www.ia.omron.com/data_pdf/guide/34/rotary_tg_e_4_1_7(engineering).pdf

PDFPressure Sensors Technical Guide
...S. 5 4 3 2 1 0 20 40 60 80 100 Pressure (kPa) Maximum value of error Full scale Output voltage (V) Hysteresis = Rated output ON pressure−OFF pressure ×100%FS Hysteresis ON OFF Pressure Pressu...

https://www.ia.omron.com/data_pdf/guide/35/pressure_tg_e_2_1_2-3(further_info).pdf

PDFProximity Sensors Technical Guide
...rs and other components. For example, whereas the voltage in a normally open switch should be 0 V in the ON state, and the same as the power supply voltage in the OFF state, residual voltage ...

https://www.ia.omron.com/data_pdf/guide/41/proximity_tg_e_5_1_5(engineering).pdf

PDFReliability Data for Safety of Machinery Photoelec...
...2. Please do NOT use this product for human bod y protection. Photoelectric sensor E3FA-T/R/D/L/V/B All models of E3FA series----405-- This product does NOT conform to requirements of I...

https://www.ia.omron.com/support/sistemalibrary/data/omron_photoelectric_sensor_en_20130401.pdf