Primary Contents

Site Search Results

Site Search Product Search IA Global Search
Results 5821 - 5830 of 6697
DRT2-[]D16SL(H)(-1) / []D32SLH(-1) Screw-less Clam...
... resistance 10 to 60 Hz, 0.7-mm double amplitude, 60 to 150 Hz, 50 m/s 2 for 80 min each in the X, Y, and Z directions Shock resistance 150m/s 2 , 6 directions, 3 times each Dielectric streng...

https://www.ia.omron.com/products/family/1488/specification.html

DRT2-[]D32B(-1) / []D32BV(-1) Board Terminals with...
... resistance 10 to 60 Hz, 0.7-mm double amplitude, 60 to 150 Hz, 50 m/s 2 for 80 min each in the X, Y, and Z directions Shock resistance 150m/s 2 , 6 directions, 3 times each Dielectric streng...

https://www.ia.omron.com/products/family/1526/specification.html

K3HB-P Timer Interval Indicator/Specifications | O...
...ibration resistance Frequency: 10 to 55 Hz; Acceleration: 50 m/s 2 , 10 sweeps of 5 min each in X, Y, and Z directions Shock resistance 150 m/s 2 (100 m/s 2 for relay outputs) 3 times each in...

https://www.ia.omron.com/products/family/1539/specification.html

E3S Photoelectric Sensor with Built-in Amplifier/D...
...e E3S-DS10E4 (41). Slit (Order Separately) E39-S2 Note 1. Three sets of slits are provided: 6.5 x 0.5 mm, 6.5 x 1 mm and 6.5 x 2 mm          2. One set consists of two slits...

https://www.ia.omron.com/products/family/1568/dimension.html

E3S Photoelectric Sensor with Built-in Amplifier/S...
...min Vibration resistance (destruction) 10 to 55 Hz, 1.5-mm double amplitude for 2 hours each in X, Y, and Z directions Shock resistance (destruction) 500 m/s 2 3 times each in X, Y, ...

https://www.ia.omron.com/products/family/1568/specification.html

CJ1W-PA / PD CJ-series Power Supply Unit/Specifica...
...8-2-6 5 to 8.4 Hz with 3.5-mm amplitude, 8.4 to 150 Hz Acceleration of 9.8 m/s 2 for 100 min in X, Y, and Z directions (10 sweeps of 10 min each = 100 min) Shock resistance Conforms to IEC600...

https://www.ia.omron.com/products/family/1639/specification.html

CJ1W-SCU CJ-series Serial Communications Units/Spe...
...ckup Function can be used with the CJ1-H and CJ1M CPU Units only.) Current consumption *3 280mA+x 400mA 360mA+x 280mA+x 380mA 380mA+x Weight 160g Max. 120g Max. 140...

https://www.ia.omron.com/products/family/1651/specification.html

E5CS Temperature Controllers/Specifications | OMRO...
...of different polarity Vibration resistance Malfunction 10 to 55 Hz, 20 m/s 2 for 10 min each in X, Y, and Z directions Destruction 10 to 55 Hz, 0.75-mm single amplitude for 2 hr each in ...

https://www.ia.omron.com/products/family/166/specification.html

CS1W-PPS01 SYSMAC CS-series Process Analog I/O Uni...
...t the number of pulses per time unit, and to convert the values to instantaneous values (pulses x pulse weight / time unit). Any of the following can be selected as the time unit: 1 s, 3 s, 1...

https://www.ia.omron.com/products/family/1671/specification.html

CS1W-CLK SYSMAC CS-series Controller Link Units/Sp...
...uplex operation of Communications Units *7 Error control Manchester code check CRC check (CCITT X 16 +X 12 +X 5 +1) *1. Product no longer available to order. *2. The maximum...

https://www.ia.omron.com/products/family/1681/specification.html

Results 5821 - 5830 of 6697