E5CC-CQ3DSM-003 | OMRON Industrial Automation
...2 Voltage output (for driving SSR) Voltage output (for driving SSR) 1 point 12 VDC±20%, Maximum load current: 21 mA, PNP, with short-circuit protection circuit Linear current output 1 point 4...

https://www.ia.omron.com/product/item/3097/

E5CC-CQ3DSM-004 | OMRON Industrial Automation
...2 Voltage output (for driving SSR) Voltage output (for driving SSR) 1 point 12 VDC±20%, Maximum load current: 21 mA, PNP, with short-circuit protection circuit Linear current output 1 point 4...

https://www.ia.omron.com/product/item/3098/

E5CC-CQ3DSM-005 | OMRON Industrial Automation
...2 Voltage output (for driving SSR) Voltage output (for driving SSR) 1 point 12 VDC±20%, Maximum load current: 21 mA, PNP, with short-circuit protection circuit Linear current output 1 point 4...

https://www.ia.omron.com/product/item/3099/

E5CC-CQ3DSM-006 | OMRON Industrial Automation
...2 Voltage output (for driving SSR) Voltage output (for driving SSR) 1 point 12 VDC±20%, Maximum load current: 21 mA, PNP, with short-circuit protection circuit Linear current output 1 point 4...

https://www.ia.omron.com/product/item/3100/

E5CC-CQ3DSM-007 | OMRON Industrial Automation
...2 Voltage output (for driving SSR) Voltage output (for driving SSR) 1 point 12 VDC±20%, Maximum load current: 21 mA, PNP, with short-circuit protection circuit Linear current output 1 point 4...

https://www.ia.omron.com/product/item/3101/

E5CC-CX0ASM-000 | OMRON Industrial Automation
...rrent output Control output 2 None Linear current output 1 point 4 to 20 mA DC / 0 to 20 mA DC, Load: 500 Ω max., Resolution: approx. 10000 Setting method Digital setting using front panel ke...

https://www.ia.omron.com/product/item/3102/

E5CC-CX0AUM-000 | OMRON Industrial Automation
...rrent output Control output 2 None Linear current output 1 point 4 to 20 mA DC / 0 to 20 mA DC, Load: 500 Ω max., Resolution: approx. 10000 Transfer output 1 point (control output alternative...

https://www.ia.omron.com/product/item/3103/

E5CC-CX0DSM-000 | OMRON Industrial Automation
...rrent output Control output 2 None Linear current output 1 point 4 to 20 mA DC / 0 to 20 mA DC, Load: 500 Ω max., Resolution: approx. 10000 Setting method Digital setting using front panel ke...

https://www.ia.omron.com/product/item/3104/

E5CC-CX0DUM-000 | OMRON Industrial Automation
...rrent output Control output 2 None Linear current output 1 point 4 to 20 mA DC / 0 to 20 mA DC, Load: 500 Ω max., Resolution: approx. 10000 Transfer output 1 point (control output alternative...

https://www.ia.omron.com/product/item/3105/

E5CC-CX1AUM-000 | OMRON Industrial Automation
...rrent output Control output 2 None Linear current output 1 point 4 to 20 mA DC / 0 to 20 mA DC, Load: 500 Ω max., Resolution: approx. 10000 Auxiliary output Number of total auxiliary output 1...

https://www.ia.omron.com/product/item/3106/

Results 6011 - 6020 of 13565