Primary Contents

Site Search Results

Site Search Product Search IA Global Search
Results 6491 - 6500 of 6520
PDFCSM_ZAP_DS_E_4_4 1 Pushbutton Switch (Cylindrical ...
...-2R ZAP-2W ZAP-2Y 2 --- 2ZAP-2B 2ZAP-2G 2ZAP-2R --- 2ZAP-2Y Item Built-in Switch Rated voltage (V) Non-inductive load (A) Inductive load (A) Resistive load Lamp load Inductive load Motor load...

https://www.ia.omron.com/data_pdf/cat/zap_ds_e_4_4_csm611.pdf

PDFCSM_ZC-_55_DS_E_3_6 1 Enclosed Switch ZC-@55
... Specifi- cation Nominal cross-sectional area (mm2) External diameter (mm) Terminal connections V.C.T. (vinyl cabtire cable) 1.25 3 conductor: 10.5 dia. Black: COM White: NO Red: NC ZC-@55 3 ...

https://www.ia.omron.com/data_pdf/cat/zc-_55_ds_e_3_6_csm587.pdf

PDFCSM_ZE_ZV_ZV2_XE_XV_XV2_DS_E_4_6
...odels. (1) Built-in Switch Z : SPDT (AC) X : SPDT (DC) (2) Mounting Direction E : Side mounting V : Base mounting V2 : Diagonal side mounting (3) Actuator Q : Plunger Q22 : Roller plunger Q21...

https://www.ia.omron.com/data_pdf/cat/ze_zv_zv2_xe_xv_xv2_ds_e_4_6_csm590.pdf

PDFSmart Sensor ZG2 Series 2D Measurement Sensor
...continuous 21.6 to 26.4 VDC (including ripple current) 0.8 A max. (per sensor head) 20 MΩat 250 V between lead wires and Controller case 1,000 VAC, 50 / 60 Hz for 1 min between lead wires and...

https://www.ia.omron.com/data_pdf/cat/zg2_q167-e1_6_8_csm2085.pdf

PDFCSM_ZJ-FA20_DS_E_2_3 1 Ionizer (Basic Fan Type) ZJ...
...00 mm, with maximum fan speed Ionization time: The time required to lower the charge from±1,000 V to±100 V Ion balance measurement time: 10 s Plate monitor: 150×150 mm, 20 pF For the...

https://www.ia.omron.com/data_pdf/cat/zj-fa20_ds_e_2_3_csm1759.pdf

PDFCSM_ZJ-FW_DS_E_1_3 1 Ionizer (Area Fan Type) ZJ-FW
...Plate monitor: 150×150 mm, 20 pF •Ionization time: Time required to lower the charge from±1,000 V to±100 V •Ion balance measurement time: 10 s Refer to Safety Precautions on page 2. ...

https://www.ia.omron.com/data_pdf/cat/zj-fw_ds_e_1_3_csm1010734.pdf

PDFCSM_ZJ-SD_DS_E_2_4 1 Smart Electrostatic Sensor ZJ...
...voltage Standard mode:±50 KV, Precision mode:±5 KV max. *1 Display resolution Standard mode: 10 V, Precision mode: 1 V *2 Linearity *3±5% FS *4 Response time 20 ms Ambient temperatur...

https://www.ia.omron.com/data_pdf/cat/zj-sd_ds_e_2_4_csm1763.pdf

PDFCSM_ZN-A_DS_E_2_4 1 Air Clean Unit ZN-A
...itch between RS-422 and RS-485. *2. Contact input: 5 mA max. ON current. Use input device of 30 V or higher withstand voltage. Item Model ZN-A2502D ZN-A4105D ZN-A6112 ZN-A6112P Air outlet dim...

https://www.ia.omron.com/data_pdf/cat/zn-a_ds_e_2_4_csm1754.pdf

PDFClean Sensing System ZN Series Advanced Clean-Moni...
...harge time: 6 s Measurement Conditions ZN-A2502 at maximum air volume Discharge time from 1,000 V to100 V Plate Monitor, 150×150 mm, 20 pF Discharge time: 2 s Discharge time: 4 s Dis...

https://www.ia.omron.com/data_pdf/cat/zn-a_zn-j_zn-pd_e383-e1_1_9_csm1570.pdf

PDFNext-Generation Production Environment Sensors
...are Multi Data Viewer Light from the following OMRON website (http://www.fa.omron.co.jp/multi-d-v-e). Easy-to-use data visualization software available Dimensions (unit: mm) [Logger] [Sensor ...

https://www.ia.omron.com/data_pdf/cat/zn-ths_thx_e409-e1_7_1_csm1003353.pdf

Results 6491 - 6500 of 6520