E5AC-CQ4ASM-011 | OMRON Industrial Automation
...t Control output 2 Voltage output (for driving SSR) Voltage output (for driving SSR) 1 point 12 VDC±20%, Maximum load current: 21 mA, PNP, with short-circuit protection circuit Linear current...

https://www.ia.omron.com/product/item/2807/

E5AC-CQ4ASM-012 | OMRON Industrial Automation
...t Control output 2 Voltage output (for driving SSR) Voltage output (for driving SSR) 1 point 12 VDC±20%, Maximum load current: 21 mA, PNP, with short-circuit protection circuit Linear current...

https://www.ia.omron.com/product/item/2808/

S8VK-S06024 | OMRON Industrial Automation
...S (30/60/120/240/480-W Models) English 日本語 Print Page Image Power rating 60 W Output voltage 24 VDC Rated input voltage 100 to 240 VAC Construction Covered type Connection Terminal blocks ...

https://www.ia.omron.com/product/item/28111/

S8VK-S12024 | OMRON Industrial Automation
... (30/60/120/240/480-W Models) English 日本語 Print Page Image Power rating 120 W Output voltage 24 VDC Rated input voltage 100 to 240 VAC Construction Covered type Connection Terminal blocks ...

https://www.ia.omron.com/product/item/28112/

E5AC-CX2ASM-000 | OMRON Industrial Automation
...s) Manual reset value 0.0 to 100.0% (in units of 0.1%) Insulation resistance 20 MΩ min. (at 500 VDC) Dielectric strength 3,000 VAC 50/60 Hz 1 min (Between current-carrying terminals of differ...

https://www.ia.omron.com/product/item/2815/

E5AC-CX2ASM-004 | OMRON Industrial Automation
...s) Manual reset value 0.0 to 100.0% (in units of 0.1%) Insulation resistance 20 MΩ min. (at 500 VDC) Dielectric strength 3,000 VAC 50/60 Hz 1 min (Between current-carrying terminals of differ...

https://www.ia.omron.com/product/item/2816/

E5AC-CX2ASM-005 | OMRON Industrial Automation
...s) Manual reset value 0.0 to 100.0% (in units of 0.1%) Insulation resistance 20 MΩ min. (at 500 VDC) Dielectric strength 3,000 VAC 50/60 Hz 1 min (Between current-carrying terminals of differ...

https://www.ia.omron.com/product/item/2817/

E5AC-CX2ASM-013 | OMRON Industrial Automation
...tput: 4 to 20 mA DC (Load: 500 Ω max., Resolution: approx. 10000) Linear voltage output: 1 to 5 VDC (Load: 1 kΩ min., Resolution: approx. 10000) Accuracy: ±0.3% FS max. Remote SP input Curren...

https://www.ia.omron.com/product/item/2818/

E5AC-CX2ASM-014 | OMRON Industrial Automation
...tput: 4 to 20 mA DC (Load: 500 Ω max., Resolution: approx. 10000) Linear voltage output: 1 to 5 VDC (Load: 1 kΩ min., Resolution: approx. 10000) Accuracy: ±0.3% FS max. Remote SP input Curren...

https://www.ia.omron.com/product/item/2819/

E5AC-CX4ASM-000 | OMRON Industrial Automation
...s) Manual reset value 0.0 to 100.0% (in units of 0.1%) Insulation resistance 20 MΩ min. (at 500 VDC) Dielectric strength 3,000 VAC 50/60 Hz 1 min (Between current-carrying terminals of differ...

https://www.ia.omron.com/product/item/2825/