1 Digital Temperature Controller- .... Control stops when you move from the operation level to the initial setting level. *1.Set the PF Setting parameter to a-m (Auto/Manual). *2.The No. 1 display will flash when the keys are pr...
https://www.ia.omron.com/data_pdf/cat/e5_d_e5_d-h_h223-e1_2_2_csm1057808.pdf
1 CSM_E5_N_E5_N-H_operation_TG_E_4_4- ...nual control level, key operations can be used to move to the operation level only. *4.When the PF Setting parameter is set to A-M for a Controller with a PF Key (E5AN/E5EN). *5.When...
https://www.ia.omron.com/data_pdf/cat/e5_n_e5_n-h_e5_n-ht_operation_tg_e_4_4_csm1375.pdf
CSM_E5AN-H_E5EN-H_DS_E_3_16 1 Advanced Digital Tem...- ...ion Accuracy •Thermocouple/Pt input: ±0.1% of PV •Analog input: ±0.1% FS Sampling Period •60 ms PF Key (Programmable key function) Auxiliary Outputs •Two •Three Remote SP Input •One 3-level D...
https://www.ia.omron.com/data_pdf/cat/e5an-h_e5en-h_ds_e_3_16_csm1377.pdf
1 Solid-state Timer H3CR Please read and understan...- ...min. Voltage Input Max. permissible capacitance between inputs lines (terminals 6 and 7): 1,200 pF Load connectable in parallel with inputs (terminals 6 and 7). •100 to 240 VAC/100 to 125 VDC...
https://www.ia.omron.com/data_pdf/cat/h3cr_l084-e1_3_6_csm1013792.pdf
CSM_H3DS_DS_E_5_4 1 Solid-state Timer H3DS- ...DC Voltage input Max. permissible capacitance between inputs lines (terminals B1 and A2): 2,000 pF Load connectable in parallel with inputs (terminals B1 and A1). H-level:20.4 to 253 VAC/20.4...
https://www.ia.omron.com/data_pdf/cat/h3ds_ds_e_5_4_csm88.pdf
CSM_H7E_-N_DS_E_9_6 1 Self-powered Totalizer New H...- ...ction. There- fore, when the input signal wiring is longer than 10 m (line capaci- tance of 120 pF/m, at room temperature), it is recommended that a CR filter or a bleeder resistor is connect...
https://www.ia.omron.com/data_pdf/cat/h7e_-n_ds_e_9_6_csm119.pdf
CSM_K2CM_DS_E_6_4 1 Motor Protective Relay K2CM- ... Hz Insulation breakdown of output contact 500 VAC Operating voltage/current of output contact (pf = 0.4 when breaking contact) NO contact: 120 VAC/2 A, 240 VAC/1 A, 440 VAC/0.5 A, 110 VDC/0....
https://www.ia.omron.com/data_pdf/cat/k2cm_ds_e_6_4_csm373.pdf
1 Advanced Motor Condition Monitoring Device K7DD- ...-7 Variable Area Map in Power Line Data Generator User’s Manual (N227). fnd thd rms fnd thd act pf freq rms V Power ON reset Power ON Adjustment Level LVL a Monitoring Level LVL Ch1 to 3 Volt...
https://www.ia.omron.com/data_pdf/cat/k7dd_n234-e1_3_3_csm1124083.pdf
•Power Monitors applicable around the globe- ...): Change of the measurement circuit / Digit shifting when a numerical value is input (2) I/V/F/PF•key [I/V/F/PF] key (measurement mode): The display of current, voltage, frequency, ...
https://www.ia.omron.com/data_pdf/cat/km-n2_km-n3_n213-e1_3_13_csm1050147.pdf
1 Safety CPU Unit NX-SL3@@@ The simplest way to in...- ... NX Unit connected to the CPU Unit is supplied through the NX bus, the IO power supply unit (NX-PF) must be used as well. Other NX units For the latest lineup of NX units, refer to our catalo...
https://www.ia.omron.com/data_pdf/cat/nx-sl3____f109-e1_1_7_csm1105361.pdf