Primary Contents

Site Search Results

Site Search Product Search IA Global Search
Results 9331 - 9340 of 9477
PDF1 Motor Condition Monitoring Device K6CM-CI
... Vibration resistance Vibration frequency 10 to 55 Hz, slice amplitude 0.35 mm in each of X, Y, Z directions 5 minute×10 Shock resistance 100 m/s2, 3 times each in 6 directions along 3 axes D...

https://www.ia.omron.com/data_pdf/cat/k6cm_n218-e1_5_4_csm1060693.pdf

PDF1 Thermal condition monitoring device K6PM-TH
...hernet ports Vibration resistance Frequency: 10 to 55 Hz, 0.35-mm single amplitude in X, Y, and Z directions (10 sweeps of 5 min each) Shock resistance 150 m/s2, 3 times each in X, Y, an...

https://www.ia.omron.com/data_pdf/cat/k6pm_h232-e1_2_3_csm1072127.pdf

PDF1 Advanced Motor Condition Monitoring Device K7DD
... to 55 Hz, 0.35-mm single amplitude, acceleration 50 m/s², 10 sweeps of 5 min each in X, Y, and Z directions Shock resistance 100 m/s2, 3 times each in X, Y, and Z axes, 6 directions...

https://www.ia.omron.com/data_pdf/cat/k7dd_n234-e1_3_3_csm1124083.pdf

PDF1 Insulation Resistance Monitoring Device K7GE-MG
... to 55 Hz, 0.35-mm single amplitude, acceleration 50 m/s2, 10 sweeps of 5 min each in X, Y, and Z directions Shock resistance 100 m/s2, 3 times each in X, Y, and Z axes, 6 directions...

https://www.ia.omron.com/data_pdf/cat/k7ge-mg_n225-e1_2_2_csm1106906.pdf

PDF1 Liquid Leakage Sensor Amplifiers K7L Series
... Hz, 0.1-mm single amplitude with 15-m/s2 acceleration for 8 minutes 10 times each in X, Y, and Z directions Shock resistance 150 m/s2 3 times each in six directions on 3 axes Wiring distance...

https://www.ia.omron.com/data_pdf/cat/k7l_n211-e1_6_7_csm1050158.pdf

PDF1 Heater Condition Monitoring Device K7TM
... to 55 Hz, 0.35-mm single amplitude, acceleration 50 m/s², 10 sweeps of 5 min each in X, Y, and Z directions Shock resistance 100 m/s2, 3 times each in X, Y, and Z axes, 6 directions...

https://www.ia.omron.com/data_pdf/cat/k7tm_n228-e1_3_3_csm1115712.pdf

PDF1 Single-phase Current Relay K8AK-AS
...resistance Frequency 10 to 55 Hz, 0.35-mm single amplitude 10 sweeps of 5 min each in X, Y, and Z directions Shock resistance 100 m/s2, 3 times each in 6 directions along 3 axes Degree of pro...

https://www.ia.omron.com/data_pdf/cat/k8ak-as_n179-e1_4_7_csm1020909.pdf

PDF1 Single-phase Overcurrent/Undercurrent Relay
...resistance Frequency: 10 to 55 Hz, 0.35-mm single amplitude 10 sweeps of 5 min each in X,Y, and Z directions Shock resistance 100 m/s2, 3 times each in 6 directions along 3 axes Degree of pro...

https://www.ia.omron.com/data_pdf/cat/k8ak-aw_n180-e1_4_8_csm1020910.pdf

PDF1 Conductive Level Controller K8AK-LS
...resistance Frequency: 10 to 55 Hz, 0.35-mm single amplitude 10 sweeps of 5 min each in X,Y, and Z directions Shock resistance 100 m/s2, 3 times each in 6 directions along 3 axes Degree of pro...

https://www.ia.omron.com/data_pdf/cat/k8ak-ls_n188-e1_4_9_csm1020918.pdf

PDF1 Three-phase Asymmetry and Phase-sequence Phase-l...
...resistance Frequency: 10 to 55 Hz, 0.35-mm single amplitude 10 sweeps of 5 min each in X,Y, and Z directions Shock resistance 100 m/s2, 3 times each in 6 directions along 3 axes Degree of pro...

https://www.ia.omron.com/data_pdf/cat/k8ak-pa_n186-e1_3_7_csm1020916.pdf

Results 9331 - 9340 of 9477