Primary Contents

IA Global Search Results

Select Country in

Site Search Product Search IA Global Search
Results 2001 - 2020 of 10962
E5ED-H Digital Temperature Controller (48 x 96 mm)...

...temperature of 23°C) Thermocouple: (±0.3% of indication value or ±1°C, whichever is greater) ±1 digit max. *1 Platinum resistance thermometer: (±0.2% of indication value or ±0.8°C, whichever ...

https://www.omron-ap.co.in/products/family/3938/specification.html

K3MA-J Process Meter/Specifications | OMRON Indust...

...ge Measuring accuracy Input impedance Displayable range DC voltage 1.000 to 5.000 V ±0.1% FS ±1 digit max. (at 23±3°C) 1 MΩ min. -19999 to 99999 (with scaling function) 0.000 to 5.000 V -5.00...

https://www.omron-ap.co.in/products/family/588/specification.html

K3MA-L Temperature Meter/Specifications | OMRON In...

...(at 23±5°C) (See note.) Thermocouple: (±0.5% of indication value or ±1°C, whichever greater) ±1 digit max. Platinum-resistance thermometer: (±0.5% of indication value or ±1°C, whichever great...

https://www.omron-ap.co.in/products/family/589/specification.html

K3MA-F Frequency/Rate Meter/Specifications | OMRON...

...in. Must be able to dependably switch a load current of 5 mA max. Measuring accuracy ±0.1%FS ±1 digit (at 23±5°C) Measurement method Cycle measurement Max. displayed digits 5 digits (-19999 t...

https://www.omron-ap.co.in/products/family/590/specification.html

S8VS Switch Mode Power Supply (15/30/60/90/120/180...

...ion: 0.1 V, Precision of output voltage indication: ±2% (percentage of output voltage value, ±1 digit) *7. Resolution of output current indication: 0.1 A; Precision of output current indicati...

https://www.omron-ap.co.in/products/family/807/specification.html

GT1-TS04[] Temperature Input Units/Specifications ...

...pt100 selectable Indicator accuracy (±0.3% of indication value or ±1°C, whichever is larger) ±1 digit max. * -200.0 to 650.0°C input range: (±0.3% of indication value or ±0.8°C, whichever is ...

https://www.omron-ap.co.nz/products/family/1083/specification.html

ZX-T Smart Sensors High-Precision Contact Type/Spe...

...lay, Present value/set value/output value display, Display reverse, ECO mode, Number of display digit changes, Sample hold, Peak hold, Bottom hold, peak-to-peak hold, Self-peak hold, Self-bot...

https://www.omron-ap.co.nz/products/family/1424/specification.html

E5GN Basic-type Digital Temperature Controller (48...

...ation accuracy Thermocouple: *1 (± 0.3% of indicated value or ± 1 °C, whichever is greater) ± 1 digit max. Platinum resistance thermometer input: (± 0.2% of indicated value or ± 0.8 °C, which...

https://www.omron-ap.co.nz/products/family/1434/specification.html

CJ1W-TC CJ Series Temperature Control Unit/Specifi...

... I/O Unit area.) Indication accuracy Celsius: ± 0.3% of PV or ± 1 ° C (whichever is larger) ± 1 digit max. Fahrenheit: ± 0.3% of PV or ± 2 ° F (whichever is larger) ± 1 digit max. L ...

https://www.omron-ap.co.nz/products/family/1438/specification.html

ZX-E Smart Sensors (Inductive Displacement Type)/S...

...pply voltage within 1.5 V OFF: Open (leakage current: 0.1 mA max.) Function - Number of display digit changes - Sample hold - Peak hold - Bottom hold, peak-to-peak hold - Self-peak hold - Sel...

https://www.omron-ap.co.nz/products/family/1457/specification.html

ZX-L-N Smart Sensors (Laser Displacement & Measure...

...vel/resolution display, scaling, display reverse, display OFF mode, ECO mode, number of display digit changes, sample hold, peak hold, bottom hold, peak-to- peak hold, self-peak hold, self-bo...

https://www.omron-ap.co.nz/products/family/1503/specification.html

DRT2-TS04[] Temperature Input Terminals/Specificat...

...to all 4 inputs. Indicator accuracy (±0.3% of indication value or ±1°C, whichever is larger) ±1 digit max. *2 -200 to 850°C input range: (±0.3% of indication value or ±0.8°C, whichever is lar...

https://www.omron-ap.co.nz/products/family/1527/specification.html

K3HB-X Process Indicator/Specifications | OMRON In...

...ous overload (30 s) K3HB-XVD DC voltage A ±199.99 V -199.99 to 219.99 V 10 MΩ min. ±0.1%rdg ± 1 digit max. ±400 V B ±19.999 V -19.999 to 21.999 V 1 MΩ min. ±200 V C ±1.9999 V -1.9999 to 2.199...

https://www.omron-ap.co.nz/products/family/1535/specification.html

K3HB-S Linear Sensor Indicator/Specifications | OM...

...ent input 0 to 20 mA 0.000 to 20.000 mA -2.000 to 22.000 mA 120 Ω max. One input: ±0.1% F.S. ±1 digit max. Two inputs: ±0.2% F.S. ±1 digit max. ±31 mA 4 to 20 mA 4.000 to 20.000 mA 2...

https://www.omron-ap.co.nz/products/family/1536/specification.html

K3HB-R Rotary Pulse Indicator/Specifications | OMR...

...lay range - 19,999 to 99,999 Measurement accuracy (at 23±5 °C) Functions F1, F6: ±0.006% rgd ±1 digit (for voltage pulse/open collector sensors) Functions F2 to F5: ±0.02% rgd ±1 ...

https://www.omron-ap.co.nz/products/family/1538/specification.html

K3HB-P Timer Interval Indicator/Specifications | O...

...haracteristics Display range - 19,999 to 99,999 Measurement accuracy (at 23±5 °C) ±0.08% rgd ±1 digit (for voltage pulse/open collector sensors) Measurement range Functions F1, F3, and F4: (I...

https://www.omron-ap.co.nz/products/family/1539/specification.html

K3HB-C Up/Down Counting Pulse Indicator/Specificat...

... change in the input signal from 15% to 95% or 95% to 15%) Display error when using prescale ±1 digit Insulation resistance 20 MΩ min. (at 500 VDC) Dielectric strength 2,300 VAC for 1 min bet...

https://www.omron-ap.co.nz/products/family/1540/specification.html

K3HB-H Temperature Indicator/Specifications | OMRO...

... to 99,999 Accuracy (at 23±5°C) Thermocouple input: (±0.3% PV or ±1°C, whichever is larger) ± 1 digit max. * Platinum resistance thermometer input: (±0.2% PV or ±0.8°C, whichever is larger) ±...

https://www.omron-ap.co.nz/products/family/1541/specification.html

F3SJ Series Safety Light Curtain/Dimensions | OMRO...

... Material : Stainless When Using Compatible Brackets Backside mounting C (protective height): 4-digit number in the Model name A = C + 159 B = C + 86 Side mounting C (protective height):...

https://www.omron-ap.co.nz/products/family/1581/dimension.html

F3SJ Series Safety Light Curtain/Lineup | OMRON In...

... for receiver) (10% Operating Range Attenuation) Appearance Model F39-HB[][][][] * * The same 4-digit numbers as the protective heights ([][][][] in the light curtain model names) are substit...

https://www.omron-ap.co.nz/products/family/1581/lineup.html

Results 2001 - 2020 of 10962

Select Country in