PDFCSM_D4B-_N_DS_E_10_12 1 Safety Limit Switch D4B-@N

... the lever can be easily changed without using any tools. It can be set to clockwise operation (CW) or counterclockwise (CCW) operation. Use the procedure given at the right to change the ope...

https://www.ia.omron.com/data_pdf/cat/d4b-_n_ds_e_10_12_csm1251.pdf

PDF1 CSM_E63-WF_DS_E_4_4 Direct Discrimination Unit E...

...TPUT OFF ON OFF ON L H IN OUT COUNTS OUTPUT Phase B UP/DOWN OFF ON OFF ON OFF ON OFF ON CCW CCW CW CW CW CCW CW CCW CW Z Z Z Z Z Z ON OFF Encoder direction...

https://www.ia.omron.com/data_pdf/cat/e63-wf_ds_e_4_4_csm489.pdf

PDF1 CSM_E6A2-C_DS_E_8_2 Incremental 25-mm-dia. Rotar...

...) 1/4±1/8T (90˚±45˚) 1/4±1/8T (90˚±45˚) T(360˚) Phase A Phase B Phase Z Phase A Phase B Phase Z CW CCW Direction of rotation: CW (as viewed from end of shaft) Direction of rotation: ...

https://www.ia.omron.com/data_pdf/cat/e6a2-c_ds_e_8_2_csm490.pdf

PDF1 CSM_E6B2-C_DS_E_6_3 Incremental 40-mm-dia. Rotar...

...) 1/4±1/8T (90˚±45˚) 1/4±1/8T (90˚±45˚) T(360˚) Phase A Phase B Phase Z Phase A Phase B Phase Z CW CCW E6B2-CWZ6C NPN Open-collector Output Model E6B2-CWZ5B PNP Open-collector Output Model Di...

https://www.ia.omron.com/data_pdf/cat/e6b2-c_ds_e_6_3_csm491.pdf

PDF1 CSM_E6C2-C_DS_E_6_4 Slim Incremental 50-mm-dia. ...

...ON OFF ON OFF ON OFF T(360˚) ON OFF ON OFF ON OFF 1/4˚±1/8T(90˚±45˚) 1/4±1/8T (90˚±45˚) T(360˚) CW CCW E6C2-CWZ6C NPN Open-collector Output Model E6C2-CWZ5B PNP Open-collector Output Model Di...

https://www.ia.omron.com/data_pdf/cat/e6c2-c_ds_e_6_4_csm493.pdf

PDF1 CSM_E6C3-A_DS_E_8_4 Slim Encoder with Diameter o...

..., low = 1) Positive logic (high = 1, low = 0) Direction of rotation*4 Output code increases for CW (as viewed from end of shaft). Switched using rotation di- rection input. Strobe signal None...

https://www.ia.omron.com/data_pdf/cat/e6c3-a_ds_e_8_4_csm494.pdf

PDFCSM_E6C3-C_DS_E_7_3 1 Rugged Incremental 50-mm-dia...

... E6C3-CWZ3EH Voltage Output Model E6C3-CWZ5GH Complementary Output Model Direction of rotation: CW Direction of rotation: CCW (as viewed from end of shaft) (as viewed from end of shaft) E6C3-...

https://www.ia.omron.com/data_pdf/cat/e6c3-c_ds_e_7_3_csm495.pdf

PDFCSM_E6CP-A_DS_E_6_5 1 Low-cost Encoder with Diamet...

...tive logic (high = 0, low = 1) Accuracy±1°max. Direction of rotation Output code incremented by CW (as viewed from the end of the shaft) Rise and fall times of output 1μs max. (Control output...

https://www.ia.omron.com/data_pdf/cat/e6cp-a_ds_e_6_5_csm496.pdf

PDFCSM_E6D-C_DS_E_5_2 1 Ordering Information

..., white, orange 30Ω 1 kΩ TTL 7407 E6D main circuit Phase A Phase B Phase Z H L H L H L (360°) T CW t1, t2, t3, t4=90°±25° (1/4T±7/100T) t1 Phase A Phase B Phase Z H L H L H L CCW t4 t3 t2 t1,...

https://www.ia.omron.com/data_pdf/cat/e6d-c_ds_e_5_2_csm497.pdf

PDF1 CSM_E6F-A_DS_E_7_5 Absolute 60-mm-dia. Rotary En...

... low = 1) Positive log- ic (high = 1, low = 0) Direction of rotation Output code incremented by CW (as viewed from the end of the shaft) Rise and fall times of output 1μs max. (E6F-AB3C, A@5C...

https://www.ia.omron.com/data_pdf/cat/e6f-a_ds_e_7_5_csm498.pdf

PDF1 CSM_E6F-C_DS_E_6_3 Incremental 60-mm-dia. Rotary...

...-CWZ5G Phase A Phase B Phase Z Phase A Phase B Phase Z T(360˚) H L H L H L T(360˚) H L H L H L CW CCW 1/4±1/8T (90˚±45˚) 1/4±1/8T (90˚±45˚) Direction of rotation: CW (as viewed from ...

https://www.ia.omron.com/data_pdf/cat/e6f-c_ds_e_6_3_csm499.pdf

PDF1 CSM_E6H-C_DS_E_6_4 Hollow-shaft Encoder with Dia...

... OFF ON OFF ON OFF ON OFF ON OFF ON OFF T(360°) Phase A Phase B Phase Z Phase A Phase B Phase Z CW CCW Direction of rotation: CW (as viewed from end of shaft) Direction of rotation: ...

https://www.ia.omron.com/data_pdf/cat/e6h-c_ds_e_6_4_csm500.pdf

PDFCSM_M22_DS_E_4_4 1 Indicator (Cylindrical 22/25-di...

...ance Color of Display Model Square (Projection) Red M22-CR Green M22-CG Yellow M22-CY White M22-CW Blue M22-CA Operating voltage 6 VAC/VDC 12 VAC/VDC 24 VAC/VDC Appearance AC/DC LED light Mod...

https://www.ia.omron.com/data_pdf/cat/m22_ds_e_4_4_csm610.pdf

PDFFast, High Quality, Easy Marking

...: 2014 Yb:Fiberレーザ最大出力:40W 最大ピークパワー:30kW パルス幅:1-500ns 波長:1062nm 半導体レーザ最大出力:1mW パルス幅:CW 波長:655nm DANGER—VISIBLE AND INVISIBLE LASER RADIATION AVOID...

https://www.ia.omron.com/data_pdf/cat/mx-z2000h-v1_q269-e1_3_1_csm1074598.pdf

PDF1 Fiber Laser Marker MX-Z2000H-V1 series

...: 2014 Yb:Fiberレーザ最大出力:40W 最大ピークパワー:30kW パルス幅:1-500ns 波長:1062nm 半導体レーザ最大出力:1mW パルス幅:CW 波長:655nm DANGER—VISIBLE AND INVISIBLE LASER RADIATION AVOID...

https://www.ia.omron.com/data_pdf/cat/mx-z2000h-v1_q343-e1_2_1_csm1111909.pdf

PDF1 Machine Automation Controller NJ-Series

...e reset Outputs M codes, and interlocks with sequence control program using reset. Spindle axis CW/CCW/Stop Outputs/stops velocity commands in velocity loop control mode. Orientation Stops sp...

https://www.ia.omron.com/data_pdf/cat/nj-series_p140-e1_6_11_csm1067136.pdf

PDFIntegrated NC and PLC functionality

...-CODE Code Function G00 Rapid Positioning G01 Liner Interpolation G02 Circular Interpolation in CW direction G03 Circular Interpolation in CCW direction G04 Dwell G09 Exact Stop G17 X-Y Plane...

https://www.ia.omron.com/data_pdf/cat/nj_r190-e1_2_1_csm1059736.pdf

PDFThe monthly news, C&N - OMRON Cost-effective Contr...

...: 100 Hz (3) Ladder Program Specifies Pulse output 0 Specifies Pulse + direction output method, CW direction, and Relative pulses Port specifier and control data settings for the PLS2 instruc...

https://www.fa.omron.co.jp/data_pdf/member/special/c_and_n/R182-E1-09.pdf

PDF月刊C&N通信 ~オムロンの超ローコスト制御機器~ Vol. Vol.1 CP1E、NB シリーズ充...

...D6 #0064 D7 #0000 パルス出力量:600,000 パルス 起動周波数:100Hz ③ ラダーの作成 パルス出力 0 指定パルス+方向出力 CW 方向相対パルス指定 PLS2 命令のポート指定とコントロールデータの設定は以下の...

https://www.fa.omron.co.jp/data_pdf/member/special/c_and_n/SBSA-940J-web1.pdf

PDFプログラマブルコント ローラ CQM1(H)シリーズ 置 き換 えガイド

...力 0 #0001=パルス出力 1 #0002=パルス出力 2 #0003=パルス出力 3 出力モード: D15~D12=0Hex 固定 D11~D08=パルス出力方式 0Hex:CW/CCW 出力 1Hex:パルス+方向出力 D07~D04=方向指定 0Hex...

https://www.fa.omron.co.jp/data_pdf/member/special/plc_replace/SBCA-094A-web1.pdf