Site Search | Product Search | IA Global Search |
...pt100 selectable Indicator accuracy (±0.3% of indication value or ±1°C, whichever is larger) ±1 digit max. * -200.0 to 650.0°C input range: (±0.3% of indication value or ±0.8°C, whichever is ...
https://www.omron-ap.com/products/family/1083/specification.html
...lay, Present value/set value/output value display, Display reverse, ECO mode, Number of display digit changes, Sample hold, Peak hold, Bottom hold, peak-to-peak hold, Self-peak hold, Self-bot...
https://www.omron-ap.com/products/family/1424/specification.html
...ation accuracy Thermocouple: *1 (± 0.3% of indicated value or ± 1 °C, whichever is greater) ± 1 digit max. Platinum resistance thermometer input: (± 0.2% of indicated value or ± 0.8 °C, which...
https://www.omron-ap.com/products/family/1434/specification.html
... I/O Unit area.) Indication accuracy Celsius: ± 0.3% of PV or ± 1 ° C (whichever is larger) ± 1 digit max. Fahrenheit: ± 0.3% of PV or ± 2 ° F (whichever is larger) ± 1 digit max. L ...
https://www.omron-ap.com/products/family/1438/specification.html
...pply voltage within 1.5 V OFF: Open (leakage current: 0.1 mA max.) Function - Number of display digit changes - Sample hold - Peak hold - Bottom hold, peak-to-peak hold - Self-peak hold - Sel...
https://www.omron-ap.com/products/family/1457/specification.html
...vel/resolution display, scaling, display reverse, display OFF mode, ECO mode, number of display digit changes, sample hold, peak hold, bottom hold, peak-to- peak hold, self-peak hold, self-bo...
https://www.omron-ap.com/products/family/1503/specification.html
...to all 4 inputs. Indicator accuracy (±0.3% of indication value or ±1°C, whichever is larger) ±1 digit max. *2 -200 to 850°C input range: (±0.3% of indication value or ±0.8°C, whichever is lar...
https://www.omron-ap.com/products/family/1527/specification.html
...ent input 0 to 20 mA 0.000 to 20.000 mA -2.000 to 22.000 mA 120 Ω max. One input: ±0.1% F.S. ±1 digit max. Two inputs: ±0.2% F.S. ±1 digit max. ±31 mA 4 to 20 mA 4.000 to 20.000 mA 2...
https://www.omron-ap.com/products/family/1536/specification.html
...lay range - 19,999 to 99,999 Measurement accuracy (at 23±5 °C) Functions F1, F6: ±0.006% rgd ±1 digit (for voltage pulse/open collector sensors) Functions F2 to F5: ±0.02% rgd ±1 ...
https://www.omron-ap.com/products/family/1538/specification.html
...haracteristics Display range - 19,999 to 99,999 Measurement accuracy (at 23±5 °C) ±0.08% rgd ±1 digit (for voltage pulse/open collector sensors) Measurement range Functions F1, F3, and F4: (I...
https://www.omron-ap.com/products/family/1539/specification.html
... change in the input signal from 15% to 95% or 95% to 15%) Display error when using prescale ±1 digit Insulation resistance 20 MΩ min. (at 500 VDC) Dielectric strength 2,300 VAC for 1 min bet...
https://www.omron-ap.com/products/family/1540/specification.html
... to 99,999 Accuracy (at 23±5°C) Thermocouple input: (±0.3% PV or ±1°C, whichever is larger) ± 1 digit max. * Platinum resistance thermometer input: (±0.2% PV or ±0.8°C, whichever is larger) ±...
https://www.omron-ap.com/products/family/1541/specification.html
... Material : Stainless When Using Compatible Brackets Backside mounting C (protective height): 4-digit number in the Model name A = C + 159 B = C + 86 Side mounting C (protective height):...
https://www.omron-ap.com/products/family/1581/dimension.html
... for receiver) (10% Operating Range Attenuation) Appearance Model F39-HB[][][][] * * The same 4-digit numbers as the protective heights ([][][][] in the light curtain model names) are substit...
...cs Setting accuracy Thermocouple *1: (±1% of indication value or ±2°C, whichever is greater) ±1 digit max. Platinum resistance thermometer *2: (±0.5% of indication value or ±1°C, whichever is...
https://www.omron-ap.com/products/family/166/specification.html
...y (25 °C) (See note.) With Celsius selected: ± 0.3% of PV or ± 1 ° C, whichever is greater, ± 1 digit max. With fahrenheit selected: ± 0.3% of PV or ± 2 ° F, whichever is greater, ± 1 ...
https://www.omron-ap.com/products/family/1664/specification.html
...ation accuracy Thermocouple input: (±0.3% of indication value or ±1°C, whichever is greater) ±1 digit max. *1 Platinum resistance thermometer input: (±0.2% of indication value or ±0.8°C, whic...
https://www.omron-ap.com/products/family/1757/specification.html
...ltage: 2 V max. Display Input voltage Display range: 17.0 to 30.0 V Display accuracy: 2% rdg ±1 digit max. Output current Branch output display range: 0.0 to 4.0 A Peak output current display...
https://www.omron-ap.com/products/family/1768/specification.html
...ng, Threshold level selection, Wide range display, Key lock, ECO mode, Display reverse, Display digit change, Initialize Measurement result display, Communications condition display, Unit sel...
https://www.omron-ap.com/products/family/1830/specification.html
...kHz: 1-input mode: 0.001 to 10 kHz Other modes: 0.01 to 5 kH Measuring accuracy --- ±0.1% FS ±1 digit max. (at 23 ±5°C) Output modes --- Input mode: Not 2-input independent measurement: Upper...