Primary Contents

IA Global Search Results

Select Country in

Site Search Product Search IA Global Search
Results 2281 - 2300 of 10962
GT1-TS04[] Temperature Input Units/Specifications ...

...pt100 selectable Indicator accuracy (±0.3% of indication value or ±1°C, whichever is larger) ±1 digit max. * -200.0 to 650.0°C input range: (±0.3% of indication value or ±0.8°C, whichever is ...

https://www.omron-ap.com/products/family/1083/specification.html

ZX-T Smart Sensors High-Precision Contact Type/Spe...

...lay, Present value/set value/output value display, Display reverse, ECO mode, Number of display digit changes, Sample hold, Peak hold, Bottom hold, peak-to-peak hold, Self-peak hold, Self-bot...

https://www.omron-ap.com/products/family/1424/specification.html

E5GN Basic-type Digital Temperature Controller (48...

...ation accuracy Thermocouple: *1 (± 0.3% of indicated value or ± 1 °C, whichever is greater) ± 1 digit max. Platinum resistance thermometer input: (± 0.2% of indicated value or ± 0.8 °C, which...

https://www.omron-ap.com/products/family/1434/specification.html

CJ1W-TC CJ Series Temperature Control Unit/Specifi...

... I/O Unit area.) Indication accuracy Celsius: ± 0.3% of PV or ± 1 ° C (whichever is larger) ± 1 digit max. Fahrenheit: ± 0.3% of PV or ± 2 ° F (whichever is larger) ± 1 digit max. L ...

https://www.omron-ap.com/products/family/1438/specification.html

ZX-E Smart Sensors (Inductive Displacement Type)/S...

...pply voltage within 1.5 V OFF: Open (leakage current: 0.1 mA max.) Function - Number of display digit changes - Sample hold - Peak hold - Bottom hold, peak-to-peak hold - Self-peak hold - Sel...

https://www.omron-ap.com/products/family/1457/specification.html

ZX-L-N Smart Sensors (Laser Displacement & Measure...

...vel/resolution display, scaling, display reverse, display OFF mode, ECO mode, number of display digit changes, sample hold, peak hold, bottom hold, peak-to- peak hold, self-peak hold, self-bo...

https://www.omron-ap.com/products/family/1503/specification.html

DRT2-TS04[] Temperature Input Terminals/Specificat...

...to all 4 inputs. Indicator accuracy (±0.3% of indication value or ±1°C, whichever is larger) ±1 digit max. *2 -200 to 850°C input range: (±0.3% of indication value or ±0.8°C, whichever is lar...

https://www.omron-ap.com/products/family/1527/specification.html

K3HB-S Linear Sensor Indicator/Specifications | OM...

...ent input 0 to 20 mA 0.000 to 20.000 mA -2.000 to 22.000 mA 120 Ω max. One input: ±0.1% F.S. ±1 digit max. Two inputs: ±0.2% F.S. ±1 digit max. ±31 mA 4 to 20 mA 4.000 to 20.000 mA 2...

https://www.omron-ap.com/products/family/1536/specification.html

K3HB-R Rotary Pulse Indicator/Specifications | OMR...

...lay range - 19,999 to 99,999 Measurement accuracy (at 23±5 °C) Functions F1, F6: ±0.006% rgd ±1 digit (for voltage pulse/open collector sensors) Functions F2 to F5: ±0.02% rgd ±1 ...

https://www.omron-ap.com/products/family/1538/specification.html

K3HB-P Timer Interval Indicator/Specifications | O...

...haracteristics Display range - 19,999 to 99,999 Measurement accuracy (at 23±5 °C) ±0.08% rgd ±1 digit (for voltage pulse/open collector sensors) Measurement range Functions F1, F3, and F4: (I...

https://www.omron-ap.com/products/family/1539/specification.html

K3HB-C Up/Down Counting Pulse Indicator/Specificat...

... change in the input signal from 15% to 95% or 95% to 15%) Display error when using prescale ±1 digit Insulation resistance 20 MΩ min. (at 500 VDC) Dielectric strength 2,300 VAC for 1 min bet...

https://www.omron-ap.com/products/family/1540/specification.html

K3HB-H Temperature Indicator/Specifications | OMRO...

... to 99,999 Accuracy (at 23±5°C) Thermocouple input: (±0.3% PV or ±1°C, whichever is larger) ± 1 digit max. * Platinum resistance thermometer input: (±0.2% PV or ±0.8°C, whichever is larger) ±...

https://www.omron-ap.com/products/family/1541/specification.html

F3SJ Series Safety Light Curtain/Dimensions | OMRO...

... Material : Stainless When Using Compatible Brackets Backside mounting C (protective height): 4-digit number in the Model name A = C + 159 B = C + 86 Side mounting C (protective height):...

https://www.omron-ap.com/products/family/1581/dimension.html

F3SJ Series Safety Light Curtain/Lineup | OMRON In...

... for receiver) (10% Operating Range Attenuation) Appearance Model F39-HB[][][][] * * The same 4-digit numbers as the protective heights ([][][][] in the light curtain model names) are substit...

https://www.omron-ap.com/products/family/1581/lineup.html

E5CS Temperature Controllers/Specifications | OMRO...

...cs Setting accuracy Thermocouple *1: (±1% of indication value or ±2°C, whichever is greater) ±1 digit max. Platinum resistance thermometer *2: (±0.5% of indication value or ±1°C, whichever is...

https://www.omron-ap.com/products/family/166/specification.html

CS1W-PTS SYSMAC CS-series Process Analog I/O Units...

...y (25 °C) (See note.) With Celsius selected: ± 0.3% of PV or ± 1 ° C, whichever is greater, ± 1 digit max. With fahrenheit selected: ± 0.3% of PV or ± 2 ° F, whichever is greater, ± 1 ...

https://www.omron-ap.com/products/family/1664/specification.html

EJ1 Modular Temperature Controller/Specifications ...

...ation accuracy Thermocouple input: (±0.3% of indication value or ±1°C, whichever is greater) ±1 digit max. *1 Platinum resistance thermometer input: (±0.2% of indication value or ±0.8°C, whic...

https://www.omron-ap.com/products/family/1757/specification.html

S8M Digital Multicircuit Protector/Specifications ...

...ltage: 2 V max. Display Input voltage Display range: 17.0 to 30.0 V Display accuracy: 2% rdg ±1 digit max. Output current Branch output display range: 0.0 to 4.0 A Peak output current display...

https://www.omron-ap.com/products/family/1768/specification.html

ZN-PD Air Particle Sensor/Specifications | OMRON I...

...ng, Threshold level selection, Wide range display, Key lock, ECO mode, Display reverse, Display digit change, Initialize Measurement result display, Communications condition display, Unit sel...

https://www.omron-ap.com/products/family/1830/specification.html

H7BX Multifunction Counter (DIN 72 × 72)/Specifica...

...kHz: 1-input mode: 0.001 to 10 kHz Other modes: 0.01 to 5 kH Measuring accuracy --- ±0.1% FS ±1 digit max. (at 23 ±5°C) Output modes --- Input mode: Not 2-input independent measurement: Upper...

https://www.omron-ap.com/products/family/1931/specification.html

Results 2281 - 2300 of 10962

Select Country in