Site Search | Product Search | IA Global Search |
...sed to Devices via HLK_UNIT Section 12-4 Offset: The offset of each PLC memory area (e.g., CIO, LR, DM, etc.). These indicate the beginning words of the memory areas used in Host Link command...
https://www.fa.omron.com.cn/data_pdf/mnu/v228-e1-02_itnc-epx-drm.pdf
...rea 2 SR 256 to SR 299 IR Area 2 IR 300 to IR 511 HR Area HR 00 to HR 99 AR Area AR 00 to AR 27 LR Area LR 00 to LR 63 TC Area TC 000 to TC 511 TR Area --- DM Area DM 0000 t...
https://www.fa.omron.com.cn/data_pdf/mnu/w903-e2-2_c200hw-mc402-e.pdf
...nge). Applicable standards Certified for conformance to UL 508, UL 1604, EMC Directive, NK, and LR Standards. Humidity 20 to 90%RH (0 to 50 °C) No condensation However, in an environment exce...
https://www.omron-ap.co.in/data_pdf/cat/ns_v405-e1_12_12_csm2140.pdf
...nge). Applicable standards Certified for conformance to UL 508, UL 1604, EMC Directive, NK, and LR Standards. Humidity 20 to 90%RH (0 to 50 °C) No condensation However, in an environment exce...
https://www.omron-ap.co.nz/data_pdf/cat/ns_v405-e1_12_12_csm2140.pdf
...mmands Addressed to Devices via HLK_UNIT Offset: The offset of each PLC memory area (e.g., CIO, LR, DM, etc.). These indicate the beginning words of the memory areas used in Host Link command...
https://www.omron-ap.co.nz/data_pdf/mnu/v228-e1-02_itnc-epx-drm.pdf
...nge). Applicable standards Certified for conformance to UL 508, UL 1604, EMC Directive, NK, and LR Standards. Humidity 20 to 90%RH (0 to 50 °C) No condensation However, in an environment exce...
https://www.omron-ap.co.th/data_pdf/cat/ns_v405-e1_12_12_csm2140.pdf
...mmands Addressed to Devices via HLK_UNIT Offset: The offset of each PLC memory area (e.g., CIO, LR, DM, etc.). These indicate the beginning words of the memory areas used in Host Link command...
https://www.omron-ap.co.th/data_pdf/mnu/v228-e1-02_itnc-epx-drm.pdf
...nge). Applicable standards Certified for conformance to UL 508, UL 1604, EMC Directive, NK, and LR Standards. Humidity 20 to 90%RH (0 to 50 °C) No condensation However, in an environment exce...
https://www.omron-ap.com.my/data_pdf/cat/ns_v405-e1_12_12_csm2140.pdf
...mmands Addressed to Devices via HLK_UNIT Offset: The offset of each PLC memory area (e.g., CIO, LR, DM, etc.). These indicate the beginning words of the memory areas used in Host Link command...
https://www.omron-ap.com.my/data_pdf/mnu/v228-e1-02_itnc-epx-drm.pdf
...nge). Applicable standards Certified for conformance to UL 508, UL 1604, EMC Directive, NK, and LR Standards. Humidity 20 to 90%RH (0 to 50 °C) No condensation However, in an environment exce...
https://www.omron-ap.com.ph/data_pdf/cat/ns_v405-e1_12_12_csm2140.pdf
...mmands Addressed to Devices via HLK_UNIT Offset: The offset of each PLC memory area (e.g., CIO, LR, DM, etc.). These indicate the beginning words of the memory areas used in Host Link command...
https://www.omron-ap.com.ph/data_pdf/mnu/v228-e1-02_itnc-epx-drm.pdf
...nge). Applicable standards Certified for conformance to UL 508, UL 1604, EMC Directive, NK, and LR Standards. Humidity 20 to 90%RH (0 to 50 °C) No condensation However, in an environment exce...
https://www.omron-ap.com/data_pdf/cat/ns_v405-e1_12_12_csm2140.pdf
...mmands Addressed to Devices via HLK_UNIT Offset: The offset of each PLC memory area (e.g., CIO, LR, DM, etc.). These indicate the beginning words of the memory areas used in Host Link command...
https://www.omron-ap.com/data_pdf/mnu/v228-e1-02_itnc-epx-drm.pdf
...nge). Applicable standards Certified for conformance to UL 508, UL 1604, EMC Directive, NK, and LR Standards. Humidity 20 to 90%RH (0 to 50 °C) No condensation However, in an environment exce...
https://www.omron.co.id/data_pdf/cat/ns_v405-e1_12_12_csm2140.pdf
...mmands Addressed to Devices via HLK_UNIT Offset: The offset of each PLC memory area (e.g., CIO, LR, DM, etc.). These indicate the beginning words of the memory areas used in Host Link command...
https://www.omron.co.id/data_pdf/mnu/v228-e1-02_itnc-epx-drm.pdf
...nge). Applicable standards Certified for conformance to UL 508, UL 1604, EMC Directive, NK, and LR Standards. Humidity 20 to 90%RH (0 to 50 °C) No condensation However, in an environment exce...
https://www.omron.com.au/data_pdf/cat/ns_v405-e1_12_12_csm2140.pdf
...mmands Addressed to Devices via HLK_UNIT Offset: The offset of each PLC memory area (e.g., CIO, LR, DM, etc.). These indicate the beginning words of the memory areas used in Host Link command...
https://www.omron.com.au/data_pdf/mnu/v228-e1-02_itnc-epx-drm.pdf
...hrough-beam Models Through-beam Models Retro-reflective Models E3Z-LT@@ E3Z-LT@@ + E39-S65A E3Z-LR@@ Operating Range at a Set Distance of 300 mm Operating Range at a Set Distance of 40 mm Dis...
https://www.omron.com.tw/data_pdf/cat/e3z-_-ul_ds_e_4_1_csm1128419.pdf
...S U S ࠔાݖ༃Փᐜጲߒ७Ⴚݖᜢ७ E3Z-□-UL 19 雷射型平行移動特性對照型對照型回歸反射型 E3Z-LT□□E3Z-LT□□+E39-S65A E3Z-LR□□ 動作領域特性(設定距離300mm)動作領域特性(設定距離40mm) 距離設定型距離設定型 E3Z-LL□□...
https://www.omron.com.tw/data_pdf/cat/e3z-_-ul_ds_tw_4_1.pdf
... 5 mA max. Applicable standards * cULus: Listed (UL508), ANSI/ISA 12.12.01, EU: EN 61131-2, NK, LR, RCM, and KC: KC Registration 5 NX-CIF Specifications of Individual Units NX-CIF101 *1. Sett...
https://www.omron.com.tw/data_pdf/cat/nx-cif_ds_e_8_2_csm1041658.pdf