| Site Search | Product Search | IA Global Search |
...Synchronous I/O refreshing and Free-Run refreshing 20 μs max./ 400 μs max. NX-ID3317 24 VDC 100 ns max./ 100 ns max. NX-ID3343 Input refreshing with input changed time only *1 NX-ID3...
... 16[][] *1 15[][] 14[][] 13[][] Processing time Instruction execution times LD Instruction 0.53 ns Math instructions (for long real data) 3.3 ns Pro- gramming Program capacity *2 Siz...
https://www.omron.com.vn/products/family/3900/specification.html
... to XS2 Data Sheet. Related Product Safety Controllers Non-Contact Door Switch Controllers G9SX-NS Appearance Safety outputs *1 Auxiliary outputs *3 Logical AND connection input Logical AND c...
...n connected to the following OMRON Safety Controllers: Non-Contact Door Switch Controller: G9SX-NS Series Safety Controller: G9SP Series or NX Series Safety Control Unit UL Certification • UL...
https://www.omron.com.vn/products/family/3920/specification.html
...Unit) Power consumption 1,500 mW max. (not including Amplifier Unit) Indicators MS (Green/Red), NS (Green/Red), L/A ETH1 (Green), U/IN PWR (Green), SS (Green/ Red) External input Mode 1: Cont...
https://www.omron.com.vn/products/family/3932/specification.html
...ft/right) Noise immunity Fast transient burst • DC power Direct infusion: 2 kV, Pulse rising: 5 ns, Pulse width: 50 ns, Burst continuation time: 15 ms/0.75 ms, Period: 300 ms, Applic...
https://www.omron.com.vn/products/family/3949/specification.html
...storage: 35% to 85% Noise immunity Operating power supply: 1,500 V (p-p) min.; pulse width: 100 ns, 1 μs; rise time: 1 ns Input/output: 1,200 V (p-p) min.; pulse width: 100 ...
https://www.omron.com.vn/products/family/571/specification.html
...mmunity ±480 V on power supply terminals in normal mode, ±1,500 V in common mode, ±1 μs, or 100 ns for square-wave noise with 1 ns Vibration resistance Vibration frequency: 10 to 55 ...
https://www.omron.com.vn/products/family/576/specification.html
...pply. Noise immunity ±1,500 V on power supply terminals in normal or common mode. ±1 μs, or 100 ns for square-wave noise with 1 ns. ±480 V on power supply terminals in normal mode. ±...
https://www.omron.com.vn/products/family/588/specification.html
...pply. Noise immunity ±1,500 V on power supply terminals in normal or common mode. ±1 μs, or 100 ns for square-wave noise with 1 ns. ±480 V on power supply terminals in normal mode. ±...
https://www.omron.com.vn/products/family/589/specification.html
...pply. Noise immunity ±1,500 V on power supply terminals in normal or common mode. ±1 μs, or 100 ns for square-wave noise with 1 ns. ±480 V on power supply terminals in normal mode. ±...
https://www.omron.com.vn/products/family/590/specification.html
... terminals Noise immunity Power input (normal mode): 600 V for 10 min with a pulse width of 100 ns to 1 μs Power input (common mode): 1.5 kV for 10 min with a pulse width of 100 ns t...
https://www.omron.com.vn/products/family/857/specification.html
...uble amplitude) Shock resistance 200 m/s 2 Noise immunity Noise level: 1.5 kV; pulse width: 100 ns to 1μs Rated voltage between positive and negative terminal blocks Rated voltage of controll...
https://www.omron.com.vn/products/family/859/specification.html
... 2 Shock resistance Malfunction: 200 m/s 2 Noise immunity Noise level: 2.0 kV; pulse width: 100 ns to 1 μs Ambient temperature Operating: 0 to 55°C (with no condensation or icing) Ambient hum...
https://www.omron.com.vn/products/family/860/specification.html
...n 100 m/s 2 Noise immunity Power input (normal mode) 600 V for 10 min with a pulse width of 100 ns to 1 μs Power input (common mode) 1.5 kV for 10 min with a pulse width of 100 ns to...
https://www.omron.com.vn/products/family/863/specification.html
...makes it easier to build the system. Host application EtherNet/IP Message communications FT P e ns ag io ss cat Me uni m m co HUB Data links Data links CJ2 CPU CJ2 CPU CJ1-EtherNet/IP Unit CX...
https://www.fa.omron.co.jp/data_pdf/cat/cj2h_cj2m_p059-e1_17_27_csm1004123.pdf
...フトウェア FA無線LANユニット SYSMAC Gateway CX-Compolet 形WE70 プログラマブルターミナル(PT) 産業用スイッチングハブ NSシリーズ WE70-AP FA WIRELESS LAN ACCESS POINT POWER MODE LAN WIRELESS WE...
https://www.fa.omron.co.jp/data_pdf/cat/cj2h_cj2m_sbca-058_17_42.pdf
...4 PST-NO Max. OFFdelay time --- *3 Auxiliary outputs 2 2 (Semi-conductor) (Semi-conductor) G9SX-NS Model G9SX-SM --- G9SX-AD@/BC/EX, G9SX-GS Common Inputs Logical and connection 1 1 (Semi-con...
https://www.fa.omron.co.jp/data_pdf/cat/g9sx_series_f120-e1_1_6_csm1119023.pdf
...ける、 停 止 検 知をセンサレスで実 現するユニット 特長 P.12 / 仕様 P.61 非接 触 式ドアスイッチコントローラ G9SX-NS プログラムレスで安 全 回 路を構 築 可 能 な非 接 触 式ドアスイッチ専 用コン...
https://www.fa.omron.co.jp/data_pdf/cat/g9sx_sgfm-116_2_7.pdf
...ing metal parts Noise immunity Square-wave noise generated by noise simulator (pulse width: 100 ns/1 μs, 1-ns rise): ±1.5 kV Static immunity Malfunction: 4 kV, Destruction: 8 kV Dest...