PDFMachine Automation Controller NX-series

...Units User’s Manual (W540) 4 Installation and Wiring Removing a Terminal Block 1 Press the lock lever on the terminal block and pull out the top of the terminal block to remove it. Lock ...

https://www.omron-ap.co.nz/data_pdf/mnu/w540-e1-08_nx-cif.pdf

PDFIndustrial PC Platform NY-series

...o install a drive: 1 Ensure the Box PC is OFF. 2 Remove the drive cover. 2 3 1 1) Push the lock lever 1 . 2) Tilt the drive cover 2 . 3) Remove the drive cover 3 . 5-6 NY-series NYB Industria...

https://www.omron-ap.co.nz/data_pdf/mnu/w553-e2-16_nyb.pdf

PDFIndustrial PC Platform NY-series

...install a drive: 1 Ensure the Panel PC is OFF. 2 Remove the drive cover. 2 3 1 1) Push the lock lever 1 . 2) Tilt the drive cover 2 . 3) Remove the drive cover 3 . 5-4 NY-series NYP Industria...

https://www.omron-ap.co.nz/data_pdf/mnu/w555-e2-16_nyp.pdf

PDFIndustrial PC Platform NY-series

...o install a drive: 1 Ensure the Box PC is OFF. 2 Remove the drive cover. 2 3 1 1) Push the lock lever 1 . 2) Tilt the drive cover 2 . 3) Remove the drive cover 3 . NY-series Industrial Box PC...

https://www.omron-ap.co.nz/data_pdf/mnu/w556-e2-08_ny512-1_00.pdf

PDFIndustrial PC Platform NY-series

...install a drive: 1 Ensure the Panel PC is OFF. 2 Remove the drive cover. 2 3 1 1) Push the lock lever 1 . 2) Tilt the drive cover 2 . 3) Remove the drive cover 3 . 5-4 NY-series Industrial Pa...

https://www.omron-ap.co.nz/data_pdf/mnu/w557-e2-10_ny532.pdf

PDFMachine Automation Controller NX-series

... Unit User’s Manual (W565) 4 Installation and Wiring Removing a Terminal Block 1 Press the lock lever on the terminal block and pull out the top of the terminal block to remove it. 4-3 Wiring...

https://www.omron-ap.co.nz/data_pdf/mnu/w565-e1-05_nx-rs.pdf

PDFMachine Automation Controller NX-series

...the terminal block. 4 - 23 4 Installation and Wiring Removing a Terminal Block 1 Press the lock lever on the terminal block and pull out the top of the terminal block to remove it. Lock ...

https://www.omron-ap.co.nz/data_pdf/mnu/w566-e1-06_nx-ts_hb.pdf

PDFMachine Automation Controller NX-series

...Option Board. Not doing so may cause unintended operation of the CPU Unit or Option Board. Lock lever Cover Lock lever 5 Cover CPU Unit 5-3-9 Attaching and Removing Option Boards Not...

https://www.omron-ap.co.nz/data_pdf/mnu/w578-e1-14_nx1p2.pdf

PDFIndustrial PC Platform NY-series

...o install a drive: 1 Ensure the Box PC is OFF. 2 Remove the drive cover. 2 3 1 1) Push the lock lever 1 . 2) Tilt the drive cover 2 . 3) Remove the drive cover 3 . NY-series IPC RTOS Controll...

https://www.omron-ap.co.nz/data_pdf/mnu/w581-e2-05_nyb1c-31___.pdf

PDFMachine Automation Controller NX-series

...ferrule and the spring. 5-49 5 Installation and Wiring 1 While pressing the terminal block lock lever, pull the terminal block and remove it. Lock lever Terminal block Attaching a Te...

https://www.omron-ap.co.nz/data_pdf/mnu/w593-e1-14_nx102.pdf

PDFMachine Automation Controller NX-series

...ferrule and the spring. 5-51 5 Installation and Wiring 1 While pressing the terminal block lock lever, pull the terminal block and remove it. Lock lever Terminal block Attaching a Te...

https://www.omron-ap.co.nz/data_pdf/mnu/w629-e1-07_nx502-1_00.pdf

PDFDigital Multicircuit Protector S8M

...5 10 M4 spring washer Removal 38 1.3 4.8 When removing the S8M from the DIN Rail, pull the lock lever down with a flat-blade screwdriver and pivot the S8M upward to remove it. Section 3-3 Wir...

https://www.omron-ap.co.nz/data_pdf/mnu/z241-e1-03_s8m.pdf

PDFSmart Power Supply S8AS USER'S MANUAL

...1.5 10 1.3 4.8 M4 spring washer Removal When removing the S8AS from the DIN Rail, pull the lock lever down with a flat-blade screwdriver and pivot the S8AS upward to remove it. CH 46 SEL ENT ...

https://www.omron-ap.co.nz/data_pdf/mnu/z269-e1-07_s8as.pdf

PDFFiber Laser Marker MX-Z2000H-V1 series

...the marker head control connector on the marker head. 2 Raise the tab in the middle of the lock lever using fingernails. The lock lever is released to allow it to move freely. 3 Pres...

https://www.omron-ap.co.nz/data_pdf/mnu/z415-e1-08_mx-z2000h-v1.pdf

PDFMiniature Power Relays MY-GS CSM_MY-GS_DS_E_4_5

... AC Coil (LED: Red) Relay with AC Coil (LED: Red) Relay with DC Coil (LED: Green) With latching lever • Useful for the operation check of relay sequence circuits. • The coil voltage AC/DC can...

https://www.omron-ap.co.th/data_pdf/cat/MY-GS_DS_E_4_5_Datasheet (2020-06).pdf

PDFKey-type Selector Switch (Detachable) (Cylindrical...

...utouts 48.9 10.8 4 (Unit: mm) 2 16 +0.2 0 dia. 24 25 min. 23.9 M16×1 33 min. Switch dismounting lever Lock ring Mounting nut (31.7) 27.4 18 24 23.5 Packing (t0.5) Recommended panel thickness:...

https://www.omron-ap.co.th/data_pdf/cat/a165k_ds_e_3_7_csm604.pdf

PDFKnob-type Selector Switch (Detachable) (Cylindrica...

... 18.5 9.5 48.9 Panel Cutouts 10.8 4 2 24 23.9 16 +0.2 0 dia. 25 min. M16×1 6 Switch dismounting lever Lock ring 33 min. Mounting nut • The lamp terminal is also provided with nonlighted model...

https://www.omron-ap.co.th/data_pdf/cat/a165s_w_ds_e_4_5_csm603.pdf

PDFPushbutton Switch (Detachable) (Lighted/Non-Lighte...

...p 2.8 2 9.5 6 48.9 Panel Cutouts 10.8 4 16 24 +0.2 0 dia. 25 min. 23.9 M16´1 Switch dismounting lever Lock ring Mounting nut 33 min. (31.7) 27.4 18 15.1 21 24 23.5 Packing (t0.5) (for oil-res...

https://www.omron-ap.co.th/data_pdf/cat/a16_ds_e_11_9_csm602.pdf

PDFKnob-type Selector Switch (Cylindrical 22/25-dia.)

...ch (Cylindrical 22/25-dia.) A22@ CSM_A22__DS_E_5_3 Install in 22-dia. or 25-dia. Panel Cutout • Lever for easily mounting and removing the Switch Unit • Finger protection mechanism on Switch ...

https://www.omron-ap.co.th/data_pdf/cat/a22__ds_e_5_3_csm608.pdf

PDFPushbutton Switch (Cylindrical 22/25-dia.)

...25-dia.) A22 CSM_A22_DS_E_8_12 Install in 22-dia. or 25-dia. Panel Cutout (When Using a Ring) • Lever for easily mounting and removing the Switch Unit. • Increase wiring efficiency with three...

https://www.omron-ap.co.th/data_pdf/cat/a22_ds_e_8_12_csm607.pdf