Primary Contents

IA Global Search Results

Select Country in

Site Search Product Search IA Global Search
Results 321 - 340 of 796
PDFCat. No. W166-E1-03 Position Control Unit

...CCW CCW Ideal position for origin proximity signal to turn OFF Positioning axis Pulse output TD VL VH CW Positioning axis CW Positioning axis CW CCW ORIGIN SEARCH (Start) Origin (Stop) ORIGIN...

https://www.fa.omron.com.cn/data_pdf/mnu/w166-e1-03_c200h_nc211.pdf

PDFCat. No. W334-E1-04 Position Control Units

... them, can all be found by means of the formulas shown below. Speed (pps) Time (ms) PD PU VM VH VL 0 TU TD TAU TAD VM: Maximum speed setting TU: Acceleration time from initial speed (...

https://www.fa.omron.com.cn/data_pdf/mnu/w334-e1-04_c200hw-nc.pdf

PDFCat. No.W334-E3-4 Position Control Units

...f them, can all be found by means of the formulas shown below. Speed (pps) Time(ms) PD PU VM VH VL 0 TU TD TAU TAD VM: Maximum speed setting TU: Acceleration time from initial speed (...

https://www.fa.omron.com.cn/data_pdf/mnu/w334-e3-4_c200hw-nc.pdf

PDFCJ1W-NC113/213/413/133/233/433

...到初始速度需要的时间以及对于它们的脉冲数都可以通过下面给出的公式求出。 VM:设置的最大速度 TU:从初始速度(VL)到目标速度(VH)所需的加速时间 TD:从目标速度(VH)到初始速度(VL)所需的减速时间 T...

https://www.fa.omron.com.cn/data_pdf/mnu/w397-c1-02_cj1w-nc.pdf

PDFOPERATION MANUAL Cat. No. W397-E1-10

...f the formulas shown below. VM: Maximum speed setting TU: Acceleration time from initial speed (VL) to target speed (VH) TD: Deceleration time from target speed (VH) to initial speed (...

https://www.fa.omron.com.cn/data_pdf/mnu/w397-e1-10_cj1w-nc.pdf

PDFMachine Automation Controller NX-series

...tting Variable Log Files Item Description Remarks File name•Project unit version 1.68 or later: VL_YYYYMMDDhhmmss.bin2 •Project unit version earlier than 1.68: VL_YYYYMMDDhhmmss.bin ...

https://www.fa.omron.com.cn/data_pdf/mnu/w639-e1-04_nx502-1_00.pdf

PDF&+:357 352),%86'3 6ODYH 8QLW

...WLRQV 7KLV VHFWLRQ FRQWDLQV DOO SDUDPHWHUVZKLFK RQO\ DSSO\ WR'3PDVWHU GHYLFHV HJ PD[LPXP PHPRU\ VL]H IRU WKH PDVWHU SDUDPHWHU VHW PD[LPXP QXPEHU RI HQWULHV LQ WKH OLVW RI DFWLYH VWDWLRQV RU W...

https://www.fa.omron.com.cn/data_pdf/mnu/w901-e2-1_c200hw-prt21.pdf

PDFSmart Sensors Laser Type ZX-L-N Series

...ser’s Manual Introduction Laser Safety Introduction The ZX-LD……, ZX-LD……L, ZX-LD……V, and ZX-LD……VL Sensor Heads are Class 2 Laser Products according to EN 60825-1 (IEC 60825-1) and Class II L...

https://www.fa.omron.com.cn/data_pdf/mnu/z197-e1-04_zx-l-n.pdf

PDF1.この製品を分解したり、改造をしないでください。 2.この製品を引火性・爆発性ガスの環境で使用しな...

...出す際には日本国政府の輸出許可申請等、必要な手続きをお取りください。 該当形式形ZX-TDS10形ZX-TDS10-V形ZX-TDS10-L ZX-TDS10-VL なお、輸出貿易管理令に該当しない直線性の仕様が異なる形式を品揃えし...

https://www.fa.omron.com.cn/data_pdf/mnu/zx-tds10_-___inst-7978671-8e.pdf

PDFLong-barrel Inductive Proximity Sensor

... E2E2-X@Y@ 25 20 at 100 VAC 120 Residual output voltage 100 ON 80 Residual output voltage 60 15 VL 30 50 OFF 300 500 100 0 40 Residual load voltage 1 3 5 10 30 50 100 t = 1 mm 3 Iron 0 1 3 5 ...

https://www.omron-ap.co.nz/data_pdf/cat/e2e2_ds_e_4_6_csm1331.pdf

PDFSpecial Models Note: E2E-series DC 2-Wire and 3-Wi...

...ge 1 3 5 10 30 E2E-X@Y@ at 200 VAC 100 ON 80 V ~ 240 Residual output voltage 200 ON 160 V ~ 120 VL VL 100 VAC A ~ 40 VL A ~ 100 Residual output voltage 60 10 50 120 V ~ 0 30...

https://www.omron-ap.co.nz/data_pdf/cat/e2e_ds_e_13_6_csm446.pdf

PDFResin-case Proximity Sensor E2F CSM_E2F_DS_E_6_5

...age 30 25 20 Residual Output Voltage 120 Residual output voltage 100 ON 80 60 5 0 1 3 5 10 30 V VL 200 VAC A 24 VAC 20 Residual Load Voltage 160 80 40 VL ON 100 VAC A A Residual outp...

https://www.omron-ap.co.nz/data_pdf/cat/e2f_ds_e_6_5_csm453.pdf

PDFChemical-resistant Proximity Sensor

...ide length of sensing object: d (mm) Residual Output Voltage E2FQ-X@Y1 at 24 VAC 5 Load voltage VL (V) Residual output voltage (V) E2FQ-X@ 4 30 24 VAC 20 Residual output voltage ON 3 V ~ 2 10...

https://www.omron-ap.co.nz/data_pdf/cat/e2fq_ds_e_5_3_csm455.pdf

PDFCylindrical Proximity Sensor E2K-X CSM_E2K-X_DS_E_...

...tective resistance mA V at 100 VAC 120 Residual output voltage 100 ON 80 E2K-X@MY@ Load voltage VL (V) 2.0 Load voltage VL (V) Leakage current (mA) Leakage Current 240 Residual outpu...

https://www.omron-ap.co.nz/data_pdf/cat/e2k-x_ds_e_9_3_csm460.pdf

PDFRugged Incremental 50-mm-dia. Rotary Encoder

...N output) Line driver output*3 Output capacity Output voltage: VH = Vcc = 3 V min. (IO = 30 mA) VL = 2 V max. (IO = −30 mA) Output current: ±30 mA Output resistance: 2 kΩ Output current: 35 m...

https://www.omron-ap.co.nz/data_pdf/cat/e6c3-c_ds_e_7_3_csm495.pdf

PDFIncremental 60-mm-dia. Rotary Encoder

...2 Output capacity Applied voltage: 30 VDC max. Output voltage: VH = Vcc −3 V min. (Io = 30 mA), VL = 2 V max. (Io = −30 mA) Sink current: 35 mA max. Output current: ±30 mA Residual voltage: 0...

https://www.omron-ap.co.nz/data_pdf/cat/e6f-c_ds_e_6_3_csm499.pdf

PDFUltra-compact Pre-wired Photomicrosensor (Non-modu...

...cc = 4.7 k+5.6 k R+Z Low level: Vcc 24 V = = 5.1 mA ≤ 50 mA Load current Ic = R R Input voltage VL ≤ 1.0 V (Residual voltage for 50-mA load current) Note: Refer to the ratings of the Sensor f...

https://www.omron-ap.co.nz/data_pdf/cat/ee-sx95_e435-e1_3_6_csm1012815.pdf

PDFEnergy saving support equipment

...(VS) T-phase (VT) N-phase (VN) R-phase S-phase T-phase --- 1 circuit V1 1-phase 2-wire L-phase (VL) 1-phase 3-wire V2 19 KM-PM Dimensions (Unit: mm) Main unit KM-PMBN-EIP 104 ±1 100 38 ±1 8.7...

https://www.omron-ap.co.nz/data_pdf/cat/km-pm_n243-e1_1_1_csm1132740.pdf

PDFLong-distance Proximity Sensor

... 80 Leakage current (mA) Distance X (mm) Sensing Area TL-LP/-LY Y 70 X 60 50 3.0 mA 100/200 VAC VL 2.5 2.0 200 VAC 1.5 40 30 1.0 100 VAC 20 0.5 10 0 0.3 0.5 −60 −40 −20 0 20 1 5 10 50 100 Loa...

https://www.omron-ap.co.nz/data_pdf/cat/tl-lp_ly_ds_e_4_2_csm1328.pdf

PDFRectangular Standard Proximity Sensor

...200 220 240 260 Power supply voltage (V) 5 4 TL-N@MY at 100 VAC TL-N@MY at 200 VAC Load voltage VL (V) Residual output voltage (V) TL-N@MD Load voltage VL (V) Residual Output Voltage...

https://www.omron-ap.co.nz/data_pdf/cat/tl-n_tl-q_ds_e_14_4_csm468.pdf

Results 321 - 340 of 796

Select Country in