MM2PN AC24 | OMRON Industrial Automation

...m switching power 1700 VA (Resistive load (cosφ = 1)) 1700 VA (Inductive load (cosφ = 0.4)) 120 W (Resistive load) 120 W (Inductive load (L/R = 7 ms)) Contact form DPDT Contact metho...

https://www.ia.omron.com/product/item/6944/

MM2PN AC6 | OMRON Industrial Automation

...m switching power 1700 VA (Resistive load (cosφ = 1)) 1700 VA (Inductive load (cosφ = 0.4)) 120 W (Resistive load) 120 W (Inductive load (L/R = 7 ms)) Contact form DPDT Contact metho...

https://www.ia.omron.com/product/item/6945/

MM2PN DC100/110 | OMRON Industrial Automation

.... Release voltage (Reset voltage) 10 % min. Maximum voltage 110 % Power consumption Approx. 2.1 W Contact Contact rated load 220 VAC 7.5 A (Resistive load (cosφ = 1)) 220 VAC 7.5 A (Inductive...

https://www.ia.omron.com/product/item/6946/

MM2PN DC12 | OMRON Industrial Automation

.... Release voltage (Reset voltage) 10 % min. Maximum voltage 110 % Power consumption Approx. 2.1 W Contact Contact rated load 220 VAC 7.5 A (Resistive load (cosφ = 1)) 220 VAC 7.5 A (Inductive...

https://www.ia.omron.com/product/item/6947/

MM2PN DC200/220 | OMRON Industrial Automation

.... Release voltage (Reset voltage) 10 % min. Maximum voltage 110 % Power consumption Approx. 2.1 W Contact Contact rated load 220 VAC 7.5 A (Resistive load (cosφ = 1)) 220 VAC 7.5 A (Inductive...

https://www.ia.omron.com/product/item/6949/

MM2PN DC24 | OMRON Industrial Automation

.... Release voltage (Reset voltage) 10 % min. Maximum voltage 110 % Power consumption Approx. 2.1 W Contact Contact rated load 220 VAC 7.5 A (Resistive load (cosφ = 1)) 220 VAC 7.5 A (Inductive...

https://www.ia.omron.com/product/item/6950/

MM2PN DC48 | OMRON Industrial Automation

.... Release voltage (Reset voltage) 10 % min. Maximum voltage 110 % Power consumption Approx. 2.1 W Contact Contact rated load 220 VAC 7.5 A (Resistive load (cosφ = 1)) 220 VAC 7.5 A (Inductive...

https://www.ia.omron.com/product/item/6951/

MM2PN DC6 | OMRON Industrial Automation

.... Release voltage (Reset voltage) 10 % min. Maximum voltage 110 % Power consumption Approx. 2.1 W Contact Contact rated load 220 VAC 7.5 A (Resistive load (cosφ = 1)) 220 VAC 7.5 A (Inductive...

https://www.ia.omron.com/product/item/6952/

MM2X AC200/(220) | OMRON Industrial Automation

...ltage 250 VAC 250 VDC Max. contact current AC: 15 A DC: 15 A Maximum switching power 20 VA 1200 W (Resistive load) 800 W (Inductive load (L/R = 7 ms)) Contact form DPDT Contact metho...

https://www.ia.omron.com/product/item/6954/

MM2X DC100/110 | OMRON Industrial Automation

.... Release voltage (Reset voltage) 10 % min. Maximum voltage 110 % Power consumption Approx. 2.1 W Contact Contact rated load 110 VDC 10 A (Resistive load) 110 VDC 7 A (Inductive load (L/R = 7...

https://www.ia.omron.com/product/item/6955/

MM2X DC12 | OMRON Industrial Automation

.... Release voltage (Reset voltage) 10 % min. Maximum voltage 110 % Power consumption Approx. 2.1 W Contact Contact rated load 110 VDC 10 A (Resistive load) 110 VDC 7 A (Inductive load (L/R = 7...

https://www.ia.omron.com/product/item/6956/

MM2X DC48 | OMRON Industrial Automation

.... Release voltage (Reset voltage) 10 % min. Maximum voltage 110 % Power consumption Approx. 2.1 W Contact Contact rated load 110 VDC 10 A (Resistive load) 110 VDC 7 A (Inductive load (L/R = 7...

https://www.ia.omron.com/product/item/6959/

MM2X DC6 | OMRON Industrial Automation

.... Release voltage (Reset voltage) 10 % min. Maximum voltage 110 % Power consumption Approx. 2.1 W Contact Contact rated load 110 VDC 10 A (Resistive load) 110 VDC 7 A (Inductive load (L/R = 7...

https://www.ia.omron.com/product/item/6960/

MM2XB AC100/(110) | OMRON Industrial Automation

...ltage 250 VAC 250 VDC Max. contact current AC: 15 A DC: 15 A Maximum switching power 20 VA 1200 W (Resistive load) 800 W (Inductive load (L/R = 7 ms)) Contact form DPDT Contact metho...

https://www.ia.omron.com/product/item/6961/

MM2XB AC200/(220) | OMRON Industrial Automation

...ltage 250 VAC 250 VDC Max. contact current AC: 15 A DC: 15 A Maximum switching power 20 VA 1200 W (Resistive load) 800 W (Inductive load (L/R = 7 ms)) Contact form DPDT Contact metho...

https://www.ia.omron.com/product/item/6962/

MM2XB AC24 | OMRON Industrial Automation

...ltage 250 VAC 250 VDC Max. contact current AC: 15 A DC: 15 A Maximum switching power 20 VA 1200 W (Resistive load) 800 W (Inductive load (L/R = 7 ms)) Contact form DPDT Contact metho...

https://www.ia.omron.com/product/item/6963/

MM2XB DC100/110 | OMRON Industrial Automation

.... Release voltage (Reset voltage) 10 % min. Maximum voltage 110 % Power consumption Approx. 2.1 W Contact Contact rated load 110 VDC 10 A (Resistive load) 110 VDC 7 A (Inductive load (L/R = 7...

https://www.ia.omron.com/product/item/6964/

MM2XB DC12 | OMRON Industrial Automation

.... Release voltage (Reset voltage) 10 % min. Maximum voltage 110 % Power consumption Approx. 2.1 W Contact Contact rated load 110 VDC 10 A (Resistive load) 110 VDC 7 A (Inductive load (L/R = 7...

https://www.ia.omron.com/product/item/6965/

MY2 AC100/110 | OMRON Industrial Automation

...: 5 A Maximum switching power 1100 VA (Resistive load) 440 VA (Inductive load (cosφ = 0.4)) 120 W (Resistive load) 48 W (Inductive load (L/R = 7 ms)) Contact form DPDT Contact method...

https://www.ia.omron.com/product/item/7255/

MY2 AC110/120 | OMRON Industrial Automation

...: 5 A Maximum switching power 1100 VA (Resistive load) 440 VA (Inductive load (cosφ = 0.4)) 120 W (Resistive load) 48 W (Inductive load (L/R = 7 ms)) Contact form DPDT Contact method...

https://www.ia.omron.com/product/item/7256/

Results 3421 - 3440 of 37966