Primary Contents

IA Global Search Results

Select Country in

Site Search Product Search IA Global Search
Results 3501 - 3520 of 49051
S8FS-G03024C | OMRON Industrial Automation

...to +15 % (With V.ADJ) Ripple 60 mV(p-p) max. Static input variation influence 0.5 % max. Static load variation influence 1.0 % max. Ambient temperature variation influence 0.05 %/℃ max. Start...

https://www.ia.omron.com/product/item/61751/

S8FS-G03024CD | OMRON Industrial Automation

...to +15 % (With V.ADJ) Ripple 60 mV(p-p) max. Static input variation influence 0.5 % max. Static load variation influence 1.0 % max. Ambient temperature variation influence 0.05 %/℃ max. Start...

https://www.ia.omron.com/product/item/61752/

S8FS-G03024CE | OMRON Industrial Automation

...to +15 % (With V.ADJ) Ripple 60 mV(p-p) max. Static input variation influence 0.5 % max. Static load variation influence 1.0 % max. Ambient temperature variation influence 0.05 %/℃ max. Start...

https://www.ia.omron.com/product/item/61753/

S8FS-G05005C | OMRON Industrial Automation

...ted output power 40 W Ripple 40 mV(p-p) max. Static input variation influence 0.5 % max. Static load variation influence 1.0 % max. Ambient temperature variation influence 0.05 %/℃ max. Start...

https://www.ia.omron.com/product/item/61754/

S8FS-G05005CD | OMRON Industrial Automation

...ted output power 40 W Ripple 40 mV(p-p) max. Static input variation influence 0.5 % max. Static load variation influence 1.0 % max. Ambient temperature variation influence 0.05 %/℃ max. Start...

https://www.ia.omron.com/product/item/61755/

H3YN-21-B AC100-120 | OMRON Industrial Automation

...icker ON start Control output (Type) Time-limit: DPDT Control output (Contact output) Resistive load: 250 VAC 5 A (cosφ=1) Minimum applicable load: 1 mA at 5 VDC (failure level: P) A...

https://www.ia.omron.com/product/item/61816/

H3YN-21-B AC200-230 | OMRON Industrial Automation

...icker ON start Control output (Type) Time-limit: DPDT Control output (Contact output) Resistive load: 250 VAC 5 A (cosφ=1) Minimum applicable load: 1 mA at 5 VDC (failure level: P) A...

https://www.ia.omron.com/product/item/61817/

H3YN-21-B AC24 | OMRON Industrial Automation

...icker ON start Control output (Type) Time-limit: DPDT Control output (Contact output) Resistive load: 250 VAC 5 A (cosφ=1) Minimum applicable load: 1 mA at 5 VDC (failure level: P) A...

https://www.ia.omron.com/product/item/61818/

H3YN-21-B DC100-110 | OMRON Industrial Automation

...icker ON start Control output (Type) Time-limit: DPDT Control output (Contact output) Resistive load: 250 VAC 5 A (cosφ=1) Minimum applicable load: 1 mA at 5 VDC (failure level: P) A...

https://www.ia.omron.com/product/item/61819/

H3YN-21-B DC12 | OMRON Industrial Automation

...icker ON start Control output (Type) Time-limit: DPDT Control output (Contact output) Resistive load: 250 VAC 5 A (cosφ=1) Minimum applicable load: 1 mA at 5 VDC (failure level: P) A...

https://www.ia.omron.com/product/item/61820/

H3YN-21-B DC125 | OMRON Industrial Automation

...icker ON start Control output (Type) Time-limit: DPDT Control output (Contact output) Resistive load: 250 VAC 5 A (cosφ=1) Minimum applicable load: 1 mA at 5 VDC (failure level: P) A...

https://www.ia.omron.com/product/item/61821/

H3YN-21-B DC24 | OMRON Industrial Automation

...icker ON start Control output (Type) Time-limit: DPDT Control output (Contact output) Resistive load: 250 VAC 5 A (cosφ=1) Minimum applicable load: 1 mA at 5 VDC (failure level: P) A...

https://www.ia.omron.com/product/item/61822/

H3YN-21-B DC48 | OMRON Industrial Automation

...icker ON start Control output (Type) Time-limit: DPDT Control output (Contact output) Resistive load: 250 VAC 5 A (cosφ=1) Minimum applicable load: 1 mA at 5 VDC (failure level: P) A...

https://www.ia.omron.com/product/item/61823/

H3YN-2-B AC100-120 | OMRON Industrial Automation

...icker ON start Control output (Type) Time-limit: DPDT Control output (Contact output) Resistive load: 250 VAC 5 A (cosφ=1) Minimum applicable load: 1 mA at 5 VDC (failure level: P) A...

https://www.ia.omron.com/product/item/61824/

H3YN-2-B AC200-230 | OMRON Industrial Automation

...icker ON start Control output (Type) Time-limit: DPDT Control output (Contact output) Resistive load: 250 VAC 5 A (cosφ=1) Minimum applicable load: 1 mA at 5 VDC (failure level: P) A...

https://www.ia.omron.com/product/item/61825/

H3YN-2-B AC24 | OMRON Industrial Automation

...icker ON start Control output (Type) Time-limit: DPDT Control output (Contact output) Resistive load: 250 VAC 5 A (cosφ=1) Minimum applicable load: 1 mA at 5 VDC (failure level: P) A...

https://www.ia.omron.com/product/item/61826/

H3YN-2-B DC100-110 | OMRON Industrial Automation

...icker ON start Control output (Type) Time-limit: DPDT Control output (Contact output) Resistive load: 250 VAC 5 A (cosφ=1) Minimum applicable load: 1 mA at 5 VDC (failure level: P) A...

https://www.ia.omron.com/product/item/61827/

H3YN-2-B DC12 | OMRON Industrial Automation

...icker ON start Control output (Type) Time-limit: DPDT Control output (Contact output) Resistive load: 250 VAC 5 A (cosφ=1) Minimum applicable load: 1 mA at 5 VDC (failure level: P) A...

https://www.ia.omron.com/product/item/61828/

H3YN-2-B DC125 | OMRON Industrial Automation

...icker ON start Control output (Type) Time-limit: DPDT Control output (Contact output) Resistive load: 250 VAC 5 A (cosφ=1) Minimum applicable load: 1 mA at 5 VDC (failure level: P) A...

https://www.ia.omron.com/product/item/61829/

H3YN-2-B DC24 | OMRON Industrial Automation

...icker ON start Control output (Type) Time-limit: DPDT Control output (Contact output) Resistive load: 250 VAC 5 A (cosφ=1) Minimum applicable load: 1 mA at 5 VDC (failure level: P) A...

https://www.ia.omron.com/product/item/61830/

Results 3501 - 3520 of 49051