Primary Contents

IA Global Search Results

Select Country in

Site Search Product Search IA Global Search
Results 3541 - 3560 of 10516
PDF[Z912-E1-02] NE1A-EDR01 EtherNet/IP-DeviceNet Rout...

...dress using the rotary switches (NODE ADR) on the front of the ED Router. Method Range Note Two-digit decimal number 0 to 63 The node address is set to 63 at the factory. Any node address in ...

https://www.fa.omron.co.jp/data_pdf/mnu/z912-e1-02_ne1a-edr01.pdf

PDF[Z916-E1-04] NE0A Series Safety Network Controller...

...s. 2-1-1 Nomenclature NE0A-SCPU01 Node address switches: Sets the DeviceNet node address as a 2-digit decimal number. Operating status indicators I/O status indicators USB port (B connector) ...

https://www.fa.omron.co.jp/data_pdf/mnu/z916-e1-04_ne0a.pdf

PDF[1668882-1E] ZN-TH11-S エアサーモセンサ 取扱説明書(日/英語)

...After the displayed number flashes for about 10 seconds, the setting completes. The upper first digit can be set as follows: [0]: Positive value [-]: Negative value [n]: No threshold setting ...

https://www.fa.omron.co.jp/data_pdf/mnu/zn-th11-s_inst-1668882-1e.pdf

PDF[2775424-9C] ZS-CRT スマートセンサ用 センサ通信ユニット 取扱説明書(日/英語)

...will be used. Know and observe all prohibitions of use applicable to this product. Set the tens digit of a node address (decimal number) on the left-hand rotary switch, and the unit ...

https://www.fa.omron.co.jp/data_pdf/mnu/zs-crt_inst-2775424-9c.pdf

PDF[1636470-8C] ZX-SB11 スマートセンサシリーズ バンクユニット 取扱説明書 (日/...

...udgement HH H PASS L LL OPE1 Lit Lit - OPE2 Lit Lit Lit - OPE3 Lit Lit ・Main Digital Display: 5-digit digital display(Red) The measured value (mm) and function names are displayed. ・Sub-dig...

https://www.fa.omron.co.jp/data_pdf/mnu/zx-sb11_inst-1636470-8c.pdf

PDFCSM_A3P_DS_E_9_3 1 Lighted Pushbutton Switch (Squa...

...rd load Silver alloy contact 1c Momentary operation A3PJ-7010-1 A3PA-7010-1 A3PT-7010-2 The end digit denotes the color of the flange: -1 denotes a black flange, and -2 denotes a light gray f...

https://www.fa.omron.com.cn/data_pdf/cat/a3p_ds_e_9_3_csm615.pdf

PDFContact Displacement Sensors D5V

... direction where the actuator turns the output OFF. B7A OUT BCD output Multipoint output #0 1’s digit = 1 Point 0 #1 1’s digit = 2 Point 1 #2 1’s digit = 4 Point 2 #3 1...

https://www.fa.omron.com.cn/data_pdf/cat/d5sn_d5m_d5v_x071-01.pdf

PDFLimit Controller E5CN-FR 1 Limit Controller

...ocouples at a temperature of−100°C max., and U and L thermocouples at any temperature is ±2°C±1 digit maximum. The indication accuracy of the B thermocouple at a temperature of 400°C max. is ...

https://www.fa.omron.com.cn/data_pdf/cat/e5cn-fr_h132-e1-01.pdf

PDF1 CSM_E5CS_DS_E_5_3 Temperature Controllers E5CS

... E5CS 4 ■Characteristics Note: 1. The following exceptions apply to thermocouples. •U, L:±2°C±1 digit max. •R:±3°C±1 digit max. at 200°C or less 2. The following exception applies to...

https://www.fa.omron.com.cn/data_pdf/cat/e5cs_ds_e_5_3_csm211.pdf

PDF1 CSM_E5ZN_DS_E_3_2 Modular Temperature Controller...

... indication accuracy for T and N thermocouples at−100°C, and for U and L thermocouples is±2°C±1 digit max. There is no specifi- cation for the indication accuracy for the B thermocouple used ...

https://www.fa.omron.com.cn/data_pdf/cat/e5zn_ds_e_3_2_csm218.pdf

PDFIoT Flow Sensors/IoT Pressure Sensors

...asured value is within the upper and lower limits. Display method Numerical value indication: 4-digit 7-segment white LED with inverting function Status indicators: The content of indication ...

https://www.fa.omron.com.cn/data_pdf/cat/e8fc_e8pc_e472-e1_4_3_csm1065029.pdf

PDF1 400-820-4535 www.fa.omron.com.cn咨询电话最新信息电话

... mA~20 mA DC1 V~5 V 输入阻抗250Ω(输入非绝缘)204 kΩ±1%(输入非绝缘) 重复精度F.S./25℃±0.2% F.S. 显示精度F.S.±0.5% F.S.±2 digit 温度特性F.S.±1% F.S. 控制输出负载电源电压: DC24 V(20.4~26....

https://www.fa.omron.com.cn/data_pdf/cat/e9nc-aa_va_scea-cn5-194f.pdf

PDFSafety Light Curtain F3SG-R Series

...5 A 150 max 150 max < Screw: M5 or M6 > F3SG-RA-30 Series Dimension A C1+18 Dimension C1 4-digit...

https://www.fa.omron.com.cn/data_pdf/cat/f3sg-r_f094-e1_12_7_csm1040037.pdf

PDFCSM_F3SN-A_F3SN-B_F3SH-A_DS_E_4_1

...eces for Emitter and Receiver) (Reduces Operating Range by 10% with Each Unit) Note: The same 4-digit numbers as the protective heights (@@@@ in the light curtain type names) are substituted ...

https://www.fa.omron.com.cn/data_pdf/cat/f3sn-a_f3sn-b_f3sh-a_ds_csm1257.pdf

PDFCSM_H5L_DS_E_2_4 1 Daily Time Switch H5L

...nges“hours”or“minutes”while setting current time. When the Plus Key is held down, the displayed digit increments continuously; when the Minus Key is held down, it decrements continuously. Whe...

https://www.fa.omron.com.cn/data_pdf/cat/h5l_ds_e_2_4_csm102.pdf

PDF1 Manual Motor Starter (Motor Protection Circuit B...

...tional unit terminal number The terminal number of Terminals A is called "13" because the first digit of the terminal number is "1" as it is mounted on the left side of the main unit, and the...

https://www.fa.omron.com.cn/data_pdf/cat/j7mc_j233-e1_5_1_csm1074610.pdf

PDF•Power Monitors applicable around the globe

...ting operations are in progress. (11) <digit. Long press: Changes the mode. (12) Key Increments the item or value. (13) Key Decrements...

https://www.fa.omron.com.cn/data_pdf/cat/km-n2_km-n3_n213-e1_3_13_csm1050147.pdf

PDFIntegrated NC and PLC functionality

... Simulation for logic, motion, robotics, safety and vision. •Advanced security function with 32 digit security password. •G-Code File Editor •Execution monitor Active G/M code display •Comman...

https://www.fa.omron.com.cn/data_pdf/cat/nj_r190-e1_2_2_csm1059736.pdf

PDFProgrammable Controller NSJ Series, NSJ

...riority Mode Instruction length 1 to 7 steps per instruction Ladder instructions Approx. 400 (3-digit function codes) Execution time Basic instructions 0.04µs min. Special instructions 0.06µs...

https://www.fa.omron.com.cn/data_pdf/cat/nsj_v406-e1_7_8_csm2192.pdf

PDF1 N X - T C N X - H T C NX-series Temperature Cont...

...CT3L Maximum heater current 50 A AC Resolution 0.1 A Overall accuracy (25°C) ±5% (full scale)±1 digit Influence of temperature (0 to 55°C) ±2% (full scale)±1 digit Conversion time 50...

https://www.fa.omron.com.cn/data_pdf/cat/nx-tc_nx-htc_h229-e1_2_2_csm1061207.pdf

Results 3541 - 3560 of 10516