PDF135 Modular PLC series Programmable

...dder diagram Instruction length 1 to 7 steps per instruction Ladder instructions Approx. 400 (3-digit function codes) Execution time Basic instructions: 0.02µs min.; Special instructions: 0.0...

https://www.fa.omron.com.cn/data_pdf/cat/p04e-en-03a cj1 groupcat.pdf

PDF1 G-series AC Servomotors/Servo Drives with Genera...

...vo Drive Part Names zMain Circuit Connector (CNA) zServomotor Connector (CNB) zDisplay Area A 6-digit 7-segment LED display shows the Servo Drive status, alarm codes, parameters, and other in...

https://www.fa.omron.com.cn/data_pdf/cat/r88m-g_r88d-gt_i814-e1_15_16_csm2686.pdf

PDFNew-generation environmental sensor

...er to the List of specifications on applicable cable diameter. Accuracy of ZN-KMX21 is±2.0%FS±1 digit (Ambient temperature 23°C, rated input, rated frequency) *1 *1: An error of the dedicated...

https://www.fa.omron.com.cn/data_pdf/cat/zn-ctx21_ctm_kmx21_e419-e1_14_1_csm1003346.pdf

PDFZX Series (ZX-L-N) Smart Sensors (Laser Type) 1

...vel/resolution display, scaling, display reverse, display OFF mode, ECO mode, number of display digit changes, sample hold, peak hold, bottom hold, peak-to-peak hold, self-peak hold, self-bot...

https://www.fa.omron.com.cn/data_pdf/cat/zx-l-n_e349-e1_1_12_csm2061.pdf

PDFE5AR-T/E5ER-T Digital Controller

... V to 240 V AC), 11 VA / 7 W max. (24 V AC/DC) Thermocouple input: (larger of±0.1% PV or±1˚C)±1 digit max. However, there are some exceptions. Analog input: (±0.1% FS)±1 digit max. P...

https://www.fa.omron.com.cn/data_pdf/mnu/e5ar-t_e5er-t_inst-1618803-9d.pdf

PDFE5AR/E5ER Digital Controller Digitaler Regler

...DC) DeviceNet power supply: 50mA max. (24 VDC) Thermocouple input: (larger of±0.1% PV or±1˚C)±1 digit max. However, there are some exceptions. Analog input: (±0.1% FS)±1 digit max. P...

https://www.fa.omron.com.cn/data_pdf/mnu/e5ar_e5er_inst-1618378-9d.pdf

PDF60ԛр 45 +0.6 0 +0.6 0 +0.6 0 δ48hঋݹᮦ䠅- 2.5ε

...couple: (Ambient temperature: 23°C) (±0.3 % of indication value or±1°C, whichever is greater)±1 digit max. Platinum resistance thermometer: (±0.2 % of indication value or±0.8°C, whichever is ...

https://www.fa.omron.com.cn/data_pdf/mnu/e5cc-8___inst-2215104-0b.pdf

PDF60以上 45 +0.6 0 +0.6 0 +0.6 0 (48×单元数量- 2.5)

...ermopar: (Temperatura ambiente: 23°C) (±0,3 % del valor de indicación o±1°C, el que sea mayor±1 digit max. Termorresistencia de platino: (±0,2 % del valor de indicación o±0,8°C, el que sea ma...

https://www.fa.omron.com.cn/data_pdf/mnu/e5cc-8___inst-5377445-2a.pdf

PDF60以上 45 +0.6 0 +0.6 0 +0.6 0 (48×单元数量- 2.5)

...ermopar: (Temperatura ambiente: 23°C) (±0,3 % del valor de indicación o±1°C, el que sea mayor±1 digit max. Termorresistencia de platino: (±0,2 % del valor de indicación o±0,8°C, el que sea ma...

https://www.fa.omron.com.cn/data_pdf/mnu/e5cc-b-8___inst-5377450-9a.pdf

PDF60ԛр 45 +0.6 0 +0.6 0 +0.6 0 δ48hঋݹᮦ䠅- 2.5ε

...couple: (Ambient temperature: 23°C) (±1.0 % of indication value or±2°C, whichever is greater)±1 digit max. Platinum resistance thermometer: (±0.2 % of indication value or±0.8°C, whichever is ...

https://www.fa.omron.com.cn/data_pdf/mnu/e5cc-u-800_inst-2290018-2b.pdf

PDF60以上 45 +0.6 0 +0.6 0 +0.6 0 (48×单元数量- 2.5)

...couple: (Ambient temperature: 23°C) (±1.0 % of indication value or±2°C, whichever is greater)±1 digit max. Platinum resistance thermometer: (±0.2 % of indication value or±0.8°C, whichever is ...

https://www.fa.omron.com.cn/data_pdf/mnu/e5cc-u-800_inst-5377446-0a.pdf

PDFOPERATION MANUAL Cat. No. H113-E1-04

...ition of a variable in the variable area, use the variable type and address. The address is a 4-digit hexadecimal code. Each variable contains an eight- digit value in hexadecimal. N...

https://www.fa.omron.com.cn/data_pdf/mnu/h113-e1-04_e5zn.pdf

PDFOPERATION MANUAL Cat. No. H119-E1-03

.... Set the DeviceNet node address (0 to 63) for the DeviceNet Communications Unit. Set the ten's digit using the upper rotary switch on the front panel, and the one's digit using the ...

https://www.fa.omron.com.cn/data_pdf/mnu/h119-e1-03_e5zn-drt.pdf

PDFUser's Manual E5AR/ER Digital Controller

...ress of the Controller to which the explicit messages (commands) will be sent in single-byte (2-digit) hexadeci- mal. Service Code, Class ID, Instance ID, Attribute ID These parameters specif...

https://www.fa.omron.com.cn/data_pdf/mnu/h124-e1-02_e5ar_e5er.pdf

PDFCat. No. H142-E1-10 User's Manual

...dication accuracy Thermocouple input (±0.5% of indication value or±1°C, whichever is greater)±1 digit max. (±0.3% of indication value or±1°C, whichever is greater)±1 digit max. Plati...

https://www.fa.omron.com.cn/data_pdf/mnu/h142-e1-10_ej1.pdf

PDFOPERATION MANUAL Cat. No. H155-E1-05

...s. Set the DeviceNet node address (0 to 63) of the DeviceNet Communications Unit. Set the ten’s digit using the×10 rotary switch, and the one’s digit using the×1 rotary switch. Set a...

https://www.fa.omron.com.cn/data_pdf/mnu/h155-e1-05_devicenet_ej1.pdf

PDFE5CN-H E5CN-H E5AN-H E5AN-H E5EN-H E5EN-H

..., Resolution: approx. 10,000 Max. heater current 50 A AC Input current readout accuracy±5% FS±1 digit max. Heater burnout alarm setting range 0.1 to 49.9 A (0.1 A units) 0.0 A: Heater burnout...

https://www.fa.omron.com.cn/data_pdf/mnu/h157-e1-08_e5cn-h_e5an-h_e5en-h.pdf

PDFCat. No. H159-E1-04 Digital Controllers

...response. Communications format Set (monitor) values Negative values Decimal point CompoWay/F 8-digit hexa- decimal 2’s complement Decimal point is removed and the result is converted to hexa...

https://www.fa.omron.com.cn/data_pdf/mnu/h159-e1-04_e5cn-h_e5an-h_e5en-h.pdf

PDFUser's Manual Programmable Digital Controller

...ghijklm ABCDEFGHIJKLM nopqrstuvwxyz NOPQRSTUVWXYZ 0123456789 - 0123456789-1 (Most signif- icant digit) 1 X●Revision History The revision code of this manual is given at the end of the catalog...

https://www.fa.omron.com.cn/data_pdf/mnu/h201-e1-03_e5ar-t_e5er-t.pdf

PDFDigital Temperature Controllers

...er. Operation indicators No. 1 display No. 2 display Temperature unit Press S Key to change the digit (default setting). Press the U D Keys to set the parameter. Front panel Press O Key for a...

https://www.fa.omron.com.cn/data_pdf/mnu/h224-e1-04_e5_d.pdf