...1,000,000次以上电气200,000次以上(AC125V时10A,电阻负载) 接点类型SPST-NO+SPST-NC 端子类型螺丝端子紧急停机开关规格开关型号A165E-M-02 操作方法慢动作,直接断开机制操作功能推动锁定,旋转复位通过...
...SPST-NO+SPST-NC Terminal type Screw terminals Emergency-stop switch specifications Switch model A165E-M-02 Operating method Slow action, Direct-opening mechanism Operating functions Push to l...
https://www.fa.omron.com.cn/data_pdf/cat/tp70_ds_e_5_5_csm576.pdf
...E1: 24V DC power source (type S8) S1: Emergency-stop switch(positive opening mechanism) (Type A165E or Type A22E) S2: Reset switch E1: 24V DC power source (type S8) L1, L2: Load E1: 24V D...
https://www.fa.omron.com.cn/data_pdf/mnu/dst1-id_m(r)d_xd__(__)sl-1_inst-1625834-7i.pdf
... E1: 24V DC power source (typeS8□□) S1: Emergency-stop switch(positive opening mechanism) (Type A165E or Type A22E) S2: Reset switch E1: 24V DC power source (typeS8□□) L1, L2: Load E1: 24V DC...
https://www.fa.omron.com.cn/data_pdf/mnu/dst1-id_m(r)d_xd__(__)sl-1_inst-2141729-1c.pdf
...-27 アプリケーション3 S1:外部テストスイッチ S2:リセットスイッチ S3:非常停止スイッチ(強制開離接点) (形A165E,形A22E) KM1, KM2:マグネット・コンタクタ(形LP1D) KM3:ソリッドステート・コンタク...
https://www.fa.omron.com.cn/data_pdf/mnu/f3sn-b_scee-717.pdf
...-34 アプリケーション3 S1:外部テストスイッチ S2:リセットスイッチ S3:非常停止スイッチ(強制開離接点) (形A165E,形A22E) KM1, KM2:マグネット・コンタクタ(形LP1D) KM3:ソリッドステート・コンタク...
https://www.fa.omron.com.cn/data_pdf/mnu/scee-713_f3sn-a.pdf
...ࡽ䕧ߎ1˄咘㡆˅ ࠊ䕧ߎ1˄㓓㡆˅ ࠊ䕧ߎ2˄ⱑ㡆˅ 0V˄㪱㡆˅ ሣ㬑 Џഫ ࠊ⬉䏃偀䖒ࠊ఼ ˄ࡼᣛҸ˅ S1 :㋻ᗹذℶᓔ݇˄㚃ᅮᮁᓔ⚍˅ (A165E, A22E) S2 :ԡᓔ݇ KM1, KM2 :⬉⺕㾺఼ RY1, RY2 :㒻⬉఼ M :3Ⳍ偀䖒 E1 :24VDC⬉⑤(S82K) ⊼1.Ϟ䗄Ꮧ㒓՟Ⳍ...
https://www.fa.omron.com.cn/data_pdf/mnu/sche-c-710a_f3sj.pdf
...tor controller (operation command) S1 :Emergency stop switch (direct circuit operation contact)(A165E, A22E) S2 :Reset switch KM1, KM2 :Magnetic contactor RY1, RY2 :Relay M :Motor E1 :24VDC p...
https://www.fa.omron.com.cn/data_pdf/mnu/schg-716n_eng_f3sj-am.pdf
...tor controller (operation command) S1 :Emergency stop switch (direct circuit operation contact)(A165E, A22E) S2 :Reset switch KM1, KM2 :Magnetic contactor RY1, RY2 :Relay M :Motor E1 :24VDC p...
https://www.fa.omron.com.cn/data_pdf/mnu/schg-718s_eng_f3sj-a.pdf
...nal and safety output 2 to T23 directly. S3 : Emergency stop switch (forcibly-opening contact) (A165E, A22E) S4 KM1 KM2 *2 Output operation mode of auxiliary output 1 is "safety output inform...
https://www.fa.omron.com.cn/data_pdf/mnu/schg-719s_eng_f3sj-a.pdf
...tor controller (operation command) S1 :Emergency stop switch (direct circuit operation contact)(A165E, A22E) S2 :Reset switch KM1, KM2 :Magnetic contactor RY1, RY2 :Relay M :Motor E1 :24VDC p...
https://www.fa.omron.com.cn/data_pdf/mnu/schg-720r_eng_f3sj-a.pdf
...tor controller (operation command) S1 :Emergency stop switch (direct circuit operation contact)(A165E, A22E) S2 :Reset switch KM1, KM2 :Magnetic contactor RY1, RY2 :Relay M :Motor E1 :24VDC p...
https://www.fa.omron.com.cn/data_pdf/mnu/schg-722n_eng_f3sj-a.pdf
...s not required) S2 : Interlock reset switch S3 : Emergency stop switch (force-opening contact) (A165E, A22E) KM1, KM2 : Safety relay with force-guided contact (G7SA) or magnetic contactor M :...
https://www.fa.omron.com.cn/data_pdf/mnu/schg-732k_eng_f3sj-e____p25_b____p25.pdf
...s not required) S2 : Interlock reset switch S3 : Emergency stop switch (force-opening contact) (A165E, A22E) KM1, KM2 : Safety relay with force-guided contact (G7SA) or magnetic contactor M :...
https://www.fa.omron.com.cn/data_pdf/mnu/schg-733j_eng_f3sj-e____n25_b____n25.pdf
...s not required) S2 : Interlock reset switch S3 : Emergency stop switch (force-opening contact) (A165E, A22E) S4 : Lockout reset switch (connect to 24V if a switch is not required) KM1, KM2 : ...
https://www.fa.omron.com.cn/data_pdf/mnu/schg-734j_eng_f3sj-b____p25-01ts.pdf
...rminal and safety output 2 to T23 directly. S3 : Emergency stop switch (force-opening contact) (A165E, A22E) KM1 KM2 Emitter Receiver F39-JD A-L F39-JD A-D Feedback loop Not Used (Red) S1 S4 ...
https://www.fa.omron.com.cn/data_pdf/mnu/schg-735j_eng_f3sj-b____n25-01t.pdf
...s not required) S2 : Interlock reset switch S3 : Emergency stop switch (force-opening contact) (A165E, A22E) S4 : Lockout reset switch (connect to 24V if a switch is not required) KM1, KM2 : ...
https://www.fa.omron.com.cn/data_pdf/mnu/schg-736j_eng_f3sj-b____p25-02ts.pdf
...㑶㡆˅ ᅝܼ䕧ߎ1˄㓓㡆˅ ᅝܼ䕧ߎ2˄ⱑ㡆˅ 0V˄㪱㡆˅ ሣ㬑 Џഫ ࠊ⬉䏃偀䖒ࠊ఼ ˄ࡼᣛҸ˅ S1 :㋻ᗹذℶᓔ݇ ˄㚃ᅮᮁᓔ⚍˅(A165E, A22E) S2 :ԡᓔ݇ KM1, KM2 :⺕㾺఼(LC1D) RY1, RY2 :㒻⬉఼ M :3Ⳍ偀䖒 E1 :24VDC⬉⑤(S82K) ⊼1.Ϟ䗄Ꮧ㒓՟...
https://www.fa.omron.com.cn/data_pdf/mnu/schg-c-718b_f3sj.pdf
...otices September 1, 2011 Emergency Stop Switches No. 2011313E Discontinuation Notice of part of A165E series Product Discontinuation Emergency Stop Switch A165E-MY series ...
https://www.fa.omron.com.cn/upload/alternative/PRDN-2011313E.pdf
...Emergency Stop Switch (16-dia.) A165E CSM_A165E_DS_E_11_5 Separate Construction with Minimal Depth • Direct opening mechanism to open contacts in emergencies, such as when they are w...
https://www.omron-ap.co.in/data_pdf/cat/a165e_ds_e_11_5_csm1264.pdf