Site Search | Product Search | IA Global Search |
...with wire gauges of AWG 28 to 24 (0.08 to 0.2 mm2). Use cable with external wire diameters of 1.61 mm max. Crimping Tools The following models are recommended for crimping tools and pressure-...
https://www.fa.omron.co.jp/data_pdf/cat/cj1w-md_ds_e_9_13_csm1618.pdf
...ith wires sized between 28 and 24 AWG (0.2 to 0.08 mm2). Use a wire with an outer diameter of 1.61 mm max. Compatible Terminal Blocks Recommended Cable XW2Z-@@@K Compatible Terminal Block Num...
https://www.fa.omron.co.jp/data_pdf/cat/cj2m-cpu3__-cpu1_-md21__ds_e_12_7_csm2201.pdf
...ox. 12.2 g PT14 Approx. 17 g PT14QN Approx. 20 g PT14-0 *2 Approx. 16.2 g 8 pins PTF11A Approx. 61 g 11 pins PTF14A Approx. 77 g 14 pins PTFZ-14-E *1 Approx. 74 g Note: The structure of @-E m...
https://www.fa.omron.co.jp/data_pdf/cat/common_sockets_ds_e_6_9_csm1819.pdf
...注.( )内の数字はDIN 規格のナンバーです。 17.2 4 (TOP VIEW) 注. レール取りつけもできます。 31以下 16以下 61以下 形P2RFZ-08 (2極) φ4.2穴 7 8-M3.5×8 1 9.5 1.5 φ4 6 3 5 4 30±0.1 39.5 30 35....
https://www.fa.omron.co.jp/data_pdf/cat/common_sockets_ds_j_6_9.pdf
...す。 11max. (10.8)* 3.1 6-φ1.1穴 2.54 共用ソケット 2.54 (1.2) 10.1max. (10)* 7 3.5 0.8 10.16 7.62 (2.61) 0.4 7.62 注. *平均寸法です。 形P6C-06P 1巻線ラッチング用/ シングルステイブ...
https://www.fa.omron.co.jp/data_pdf/cat/common_sockets_emc_ds_j_1_8.pdf
...I) cable, use a GI optical cable that matches the specifications. Programmable Controllers CS1D 61 Controller Link Support Boards Name Specifications Communications cable Controller Link Supp...
https://www.fa.omron.co.jp/data_pdf/cat/cs1d-cpu__s_bc082s_etn21d_r103-e1_9_22_csm1004122.pdf
...munity Conforms to IEC 61000-4-4 2 kV (applied to PLC power supply). Vibration resistance 10 to 61.2 Hz with single-amplitude of 0.1 mm, 61.2 to 150 Hz and 14.7 m/s2 in X, Y, and Z d...
https://www.fa.omron.co.jp/data_pdf/cat/cs1w-crm21_ds_e_9_5_csm1636.pdf
...消費電流(A) 5V系 26V系 0.4 ― 1ライセンス版* メディア:DVD 形式 形CS1W-CRM21 形CXONE-AL01D-V4 標準価格 (¥) 61,000 250,000 *CX-Oneはマルチライセンス商品(3、10、30、50ライセンス) 、およ...
https://www.fa.omron.co.jp/data_pdf/cat/cs1w-crm21_ds_j_9_9.pdf
...therNet/IP Unit. Network Configurator version 3.74a or higher is included with CX-One version 4.61 or higher. The Network Configurator provides the following functions for building, setting, ...
https://www.fa.omron.co.jp/data_pdf/cat/cs1w-eip21_eip21s_ds_e_7_9_csm1782.pdf
...Ver.3.0以降 (CX-One Ver.3.0以降)、形CS1W-EIP21Sを使用する場合には、Network Configurator Ver.3.74a以降(CX-One Ver.4.61以降)が必要です。 下記にNetwork Configuratorのおもな仕様を示します。 項...
https://www.fa.omron.co.jp/data_pdf/cat/cs1w-eip21_eip21s_ds_j_7_12.pdf
...gner version 3.3 or higher is also required. To connect the NJ3 Controller, NS system version 8.61 or higher is required. CX-Designer version 3.4 or higher is also required. *1. Multi license...
https://www.fa.omron.co.jp/data_pdf/cat/cx-designer_ds_e_5_10_csm1000602.pdf
...システムVer.8.5以降、CX-Designer Ver.3.3以降が必要です。 コントローラNJ3と接続してご使用の場合は、NS本体システムVer.8.61以降、CX-Designer Ver.3.4以降が必要です。 *1. Sysmac Studioはマルチラ...
https://www.fa.omron.co.jp/data_pdf/cat/cx-designer_ds_j_5_13.pdf
...M2C-S100C/110C CPM2C-S110C-DRT CQM1 CQM1-CPU11/21/41/42/43/44/45 CQM1H-series CQM1H-CPU11/21/51/61 CV1000 CV1000-CPU01 (-V1) CV2000 CV2000-CPU01 (-V1) CV500 CV500-CPU01 (-V1) CVM1 CVM1-CPU01/...
https://www.fa.omron.co.jp/data_pdf/cat/cx-programmer_ds_e_11_10_csm2060.pdf
...M2C-S100C/110C 形CPM2C-S110C-DRT CQM1 形CQM1-CPU11/21/41/42/43/44/45 CQM1Hシリーズ 形CQM1H-CPU11/21/51/61 CV1000 形CV1000-CPU01(-V1) CV2000 形CV2000-CPU01(-V1) CV500 形CV500-CPU01(-V1) ...
https://www.fa.omron.co.jp/data_pdf/cat/cx-programmer_ds_j_11_12.pdf
...Z/CPU85-Z C200HG-CPU33-Z/CPU43-Z/CPU53-Z/CPU63-Z C200HE-CPU32-Z/CPU42-Z CQM1H CQM1H-CPU11/21/51/61 Communication Boards/Units Series Serial Communication I/O Unit CS1W-SCU21(-V1)/SCU31-V1/SCB...
https://www.fa.omron.co.jp/data_pdf/cat/cx-protocol_ds_e_7_9_csm2078.pdf
...PU85-Z 形C200HG-CPU33-Z/CPU43-Z/CPU53-Z/CPU63-Z 形C200HE-CPU32-Z/CPU42-Z CQM1H 形CQM1H-CPU11/21/51/61 コミュニケーションボード/ユニットシリーズ シリアル通信I/Oユニット形式 CS 形CS1W-SCU21(-V...
https://www.fa.omron.co.jp/data_pdf/cat/cx-protocol_ds_j_7_10.pdf
... speed 0.05 to 0.5 m/s Operating frequency 30 operations/minute max. Direct opening force *3 19.61 N min. (EN60947-5-1) Direct opening travel *3 20 mm min. (EN60947-5-1) Holding force (Fzh) 7...
https://www.fa.omron.co.jp/data_pdf/cat/d4bl_ds_e_10_7_csm1241.pdf
...4-ターミナルプレート 2-φ7 (7) 2-LED (16) 26.8 53.2 57.2 (16) 0.3 5.6 10.6 2 (12.6) (35) 26.2 (61.2) 接続内部回路図表示灯 ソレノイド AC/DC10∼115V R ↑ ZD DC24V E1 (+) LED ↓↓ R E2...
...eed 0.1 m/s to 0.5 m/s Operating frequency 30 operations/minute max. Direct opening force *3 19.61 N min. (EN60947-5-1) Direct opening travel *3 20 mm min. (EN60947-5-1) Contact resistance 25...
https://www.fa.omron.co.jp/data_pdf/cat/d4bs_ds_e_8_7_csm1237.pdf
...nal 31/33 Terminal 32/34 LED indicator Terminal 41 Terminal 42 Terminal 51 Terminal 52 Terminal 61/63 Terminal 62/64 41 42 11 12 51 52 21 22 63 64 33 34 Conduit outlet Conduit outlet Note: Th...
https://www.fa.omron.co.jp/data_pdf/cat/d4jl_d4jl-sk40_ds_e_10_7_csm1239.pdf