Site Search | Product Search | IA Global Search |
...ted current (Nominal value) 50 Hz: 0.140 A 60 Hz: 0.120 A Rated input (Nominal value) 50 Hz: 11 W 60 Hz: 10 W Rated rotational speed (Nominal value) 50 Hz: 2100 r/min 60 Hz: 2250 r/m...
...ated current (Nominal value) 50 Hz: 0.085 A 60 Hz: 0.070 A Rated input (Nominal value) 50 Hz: 7 W 60 Hz: 6 W Rated rotational speed (Nominal value) 50 Hz: 2600 r/min 60 Hz: 3000 r/mi...
...ated current (Nominal value) 50 Hz: 0.055 A 60 Hz: 0.048 A Rated input (Nominal value) 50 Hz: 5 W 60 Hz: 4 W Rated rotational speed (Nominal value) 50 Hz: 1900 r/min 60 Hz: 2100 r/mi...
...ted current (Nominal value) 50 Hz: 0.120 A 60 Hz: 0.100 A Rated input (Nominal value) 50 Hz: 10 W 60 Hz: 9 W Rated rotational speed (Nominal value) 50 Hz: 2700 r/min 60 Hz: 3200 r/mi...
...ated current (Nominal value) 50 Hz: 0.080 A 60 Hz: 0.070 A Rated input (Nominal value) 50 Hz: 7 W 60 Hz: 6 W Rated rotational speed (Nominal value) 50 Hz: 2200 r/min 60 Hz: 2500 r/mi...
...ted current (Nominal value) 50 Hz: 0.125 A 60 Hz: 0.100 A Rated input (Nominal value) 50 Hz: 13 W 60 Hz: 11 W Rated rotational speed (Nominal value) 50 Hz: 2550 r/min 60 Hz: 3050 r/m...
...ated current (Nominal value) 50 Hz: 0.090 A 60 Hz: 0.075 A Rated input (Nominal value) 50 Hz: 7 W 60 Hz: 6 W Rated rotational speed (Nominal value) 50 Hz: 1900 r/min 60 Hz: 2200 r/mi...
... Release voltage (Reset voltage) 15 % min. Maximum voltage 110 % Power consumption Approx. 0.53 W Contact Contact rated load 250 VAC 10 A (Resistive load) 250 VAC 7.5 A (Inductive load (cosφ ...
... Release voltage (Reset voltage) 15 % min. Maximum voltage 110 % Power consumption Approx. 0.53 W Contact Contact rated load 250 VAC 10 A (Resistive load) 250 VAC 7.5 A (Inductive load (cosφ ...
... Release voltage (Reset voltage) 15 % min. Maximum voltage 110 % Power consumption Approx. 0.53 W Contact Contact rated load 250 VAC 10 A (Resistive load) 250 VAC 7.5 A (Inductive load (cosφ ...
... Release voltage (Reset voltage) 15 % min. Maximum voltage 110 % Power consumption Approx. 0.53 W Contact Contact rated load 250 VAC 10 A (Resistive load) 250 VAC 7.5 A (Inductive load (cosφ ...
... Release voltage (Reset voltage) 15 % min. Maximum voltage 110 % Power consumption Approx. 0.53 W Contact Contact rated load 250 VAC 10 A (Resistive load) 250 VAC 7.5 A (Inductive load (cosφ ...
... Release voltage (Reset voltage) 15 % min. Maximum voltage 110 % Power consumption Approx. 0.53 W Contact Contact rated load 250 VAC 10 A (Resistive load) 250 VAC 7.5 A (Inductive load (cosφ ...
...10 A Maximum switching power 2500 VA (Resistive load) 1875 VA (Inductive load (cosφ = 0.4)) 300 W (Resistive load) 150 W (Inductive load (L/R = 7 ms)) Contact form SPDT Contact metho...
...rox. 1.8 VA (at 120 VAC 60 Hz)/Relay OFF: Approx. 1 VA (at 120 VAC 60 Hz) Relay ON: Approx. 1.6 W (at 120 VAC 60 Hz)/Relay OFF: Approx. 0.6 W (at 120 VAC 60 Hz) Reset voltage 10% max...
...x. 2.2 VA (at 230 VAC 60 Hz)/Relay OFF: Approx. 1.5 VA (at 230 VAC 60 Hz) Relay ON: Approx. 1.8 W (at 230 VAC 60 Hz)/Relay OFF: Approx. 1.1 W (at 230 VAC 60 Hz) Reset voltage 10% max...
...rox. 1.8 VA (at 24 VAC 60 Hz)/Relay OFF: Approx. 0.3 VA (at 24 VAC 60 Hz) Relay ON: Approx. 1.4 W (at 24 VAC 60 Hz)/Relay OFF: Approx. 0.2 W (at 24 VAC 60 Hz) Reset voltage 10% max. ...
...e variable range 85 to 110% of the power supply voltage Power consumption Relay ON: Approx. 1.6 W (at 110 VDC)/Relay OFF: Approx. 0.4 W (at 110 VDC) Reset voltage 10% max. of rated s...
...e variable range 90 to 110% of the power supply voltage Power consumption Relay ON: Approx. 1.1 W (at 12 VDC)/Relay OFF: Approx. 0.1 W (at 12 VDC) Reset voltage 10% max. of rated sup...
...e variable range 85 to 110% of the power supply voltage Power consumption Relay ON: Approx. 1.6 W (at 125 VDC)/Relay OFF: Approx. 0.4 W (at 125 VDC) Reset voltage 10% max. of rated s...