Site Search | Product Search | IA Global Search |
...照参考手册的指示进行。 ●请不要把安装到CPU单元内置RS232C端口、或CPU单元的RS-232C备选板的第6脚(+5V电源)与转换适配器形CJ1W-CIF11/形NT-AL001/形NV3W-M□ 20L可编程终端以外的外部设备连接。 否则可能...
https://www.fa.omron.com.cn/data_pdf/mnu/cp1e-cpu(safetyprecautions)_inst-1131077-4b.pdf
...ct pin 6 (+5V) on the RS-232C of the CPU Unit to any external device other than the NT-AL001 or CJ1W-CIF11 Conversion Adapter or NV3W-Mڧ20L Pro- grammable terminal. The external device and th...
...ࠋ ەCPUࣘࢽࢵࢺෆⶶRS232C࣏࣮ࢺࠊࡲࡓࡣCPUࣘࢽࢵࢺ╔ࡋࡓRS-232C࢜ࣉࢩࣙ ࣮ࣥ࣎ࢻࡢ6␒ࣆࣥ㸦+5V㟁※㸧ࡣࠊኚࢲࣉࢱᙧCJ1W-CIF11/ᙧNT-AL001ࠊࣉ ࣟࢢ࣐ࣛࣈࣝࢱ࣮࣑ࢼࣝᙧNV3W-Mڧ20L௨እࡢእ㒊ᶵჾࡣ᥋⥆ࡋ࡞࠸࡛ࡃࡔࡉ࠸ࠋ እ㒊ᶵჾ࠾ࡼࡧCPUࣘࢽࢵࢺࡀᨾ㞀ࡍ...
... Channels 1 to 4 TC4 EDU Heater plate Wafer Temperature Sensor NS5 Programmable Terminal RS-485 CJ1W-CIF11 RS-422A Converter RUN 43 Multi-channel Control Section 3-2 3-2-2 Wiring Connect the ...
...高效通信(非无程序)。 详情请参照“4-5基于Modbus通信的上载/下载设定”(第4-16页)。 SYSMAC CS/CJ/CP系列 (注)使用RS-232C端口时,需要CJ1W-CIF11(RS-232C-422A/485转换器)。 *1安装在上述可选板插槽中使用...
... 6-11: Added information on Applicable PLC Memory Addresses. Page 6-33: Corrected the figure of CJ1W-CIF11 in 6-5-1 Configuration and Procedure. 04 September 2022 Added information on Safety ...
https://www.fa.omron.com.cn/data_pdf/mnu/h225-e1-04_e5_d.pdf
...高效通信(非无程序)。 详情请参照“4-5基于Modbus通信的上载/下载设定”(第4-16页)。 SYSMAC CS/CJ/CP系列 (注)使用RS-232C端口时,需要CJ1W-CIF11(RS-232C-422A/485转换器)。 *1安装在上述可选板插槽中使用...
...nd Download Settings for Modbus Communications. SYSMAC CS/CJ-series and CP-series PLCs Note The CJ1W-CIF11 RS-422A Converter is required to use an RS-232C port. *1 The Option Board is mounted...
https://www.fa.omron.com.cn/data_pdf/mnu/h240-e1-01_e5_d-h.pdf
... 180 g以下 1-21 系统构成第1-2章节 1 注1.使用NT-AL001链接适配器时,每增加一个单元,电流消耗增加0.15A。 使用CJ1W-CIF11 RS-422A转换适配器时,每增加一个单元,电流消耗增加 0.04A。 使用NV3W-M□20L可...
https://www.fa.omron.com.cn/data_pdf/mnu/sbca-cn5-340h_cp1h.pdf
... CPU单元相联] 不允许允许协议连接说明端口外设RS-232C 㓪Ꮉ ˄䴲ᣕᓣ㓪఼˅ RS-422A/485 RS-232C CJ1M CPUऩܗ 䕂䆶ऩܗ CJ1W-CIF11 䖲ࠄ RS-232Cッষ ᇍѢNS㋏߫PT˖ NS-AL002 CJ1M CPUऩܗ 㹿䕂䆶ऩܗ CJ1M CPUऩܗ 㹿䕂...
https://www.fa.omron.com.cn/data_pdf/mnu/w394-c1-03_cs_cj.pdf
...内置RS-232C端口或CPU单元搭载的RS-232C选件板(CP1W-CIF01)的引脚6(+5V) 可连接至下列设备,请勿将该引脚连接至其它设备。 ·RS-422A CJ1W-CIF11转换适配器 ·RS-232C/RS-422A NT-AL001转换适配器 ·NV3W-M□20...
https://www.fa.omron.com.cn/data_pdf/mnu/w479-cn5-08_cp1e.pdf
... Board (CP1W-CIF01) mounted to the CPU Unit. Do not connect pin 6 to any other device. •RS-422A CJ1W-CIF11 Conversion Adapter •RS-232C / RS-422A NT-AL001 Conversion Adapter •NV3W-M20L Progra...
https://www.fa.omron.com.cn/data_pdf/mnu/w479-e1-11_cp1e.pdf
... supply) on the RS-232C port on the CPU Unit to any device other than an NT-AL001 Link Adapter, CJ1W-CIF11 Converter, and Programmable Terminals (NV3W- M@20L). The external device or the CPU ...
https://www.fa.omron.com.cn/data_pdf/mnu/w486-e1-02_cj2m-cpu_-md21_.pdf
...-CPU6@P CPU Unit version 1.3 or later is required. 14 Memory Card Programmable Controllers CS1D CJ1W-CIF11 Configuration Units Basic I/O Units 8 I/O points 16 I/O points 32 I/O points 64 I/O ...
https://www.omron-ap.co.in/data_pdf/cat/cs1d-cpu__s_bc082s_etn21d_r103-e1_9_23_csm1004122.pdf
...L INIT. SW PRPHL COMM A39512 RSV PORT ON PORT DUPLEX RS-232C CX-Programmer NT-AL001 RS-422A/485 CJ1W-CIF11 or RS-422A/485 NT-AL001 RS-422A Adapter 41 Ordering Information Name USB-Serial Conv...
https://www.omron-ap.co.in/data_pdf/cat/plc-based_process_control_p051-e1_9_17_csm2684.pdf
...照参考手册的指示进行。 ●千万不要将 CPU 单元上 RS-232 口上的引脚 6(5V 电源)与其它设备连接,除非设备上用了转换适配器 CJ1W-CIF11/NT-AL001、可编程终端 NV3W-M□20L。 否则会损坏外部设备或 CPU 单元...
...) on the RS-232C Option Board on the CPU Unit to any external device other than the NT-AL001 or CJ1W-CIF11 Conversion Adapter or NV3W-Mƶ20L Programmable terminal. The external device and the ...
...his example configuration, an EJ1 controls a 4-zone heater plate. NS5 Programmable Terminal RUN CJ1W-CIF11 RS-422A Converter RS-485 Wafer Temperature Sensor Heater plate Control outputs: Chan...
... 6-11: Added information on Applicable PLC Memory Addresses. Page 6-33: Corrected the figure of CJ1W-CIF11 in 6-5-1 Configuration and Procedure. Added information on Safety Precautions. E5@D ...
... ports. Connect to the above Serial Communications Unit. Option board slot RS-422A/485 Note The CJ1W-CIF11 RS-422A Converter is required to use an RS-232C port. *1 The Option Board is mounted...
https://www.omron-ap.co.in/data_pdf/mnu/h240-e1-01_e5_d-h.pdf