CK3A-G305L / -G310L / -G320L CK3A-series Direct PW...

...nternal shunt resistor specification 25 Ω 30 W 17 Ω 80 W Built-in capacitors absorption energy [J] 46 J 62 J Internal shunt resistor average regeneration energy [W] 18 W 32 ...

https://www.omron-ap.co.th/products/family/3851/specification.html

K7TM Heater Condition Monitoring Device/Specificat...

...y ±0.5% FS ±1 digit Input range 0 to 600 V AC, 50/60 Hz Recommend external fuse Class CC, Class J, or Class T with a rated current of 7 A or less CH1 CT input CH2 CT input Measurement accurac...

https://www.omron-ap.co.th/products/family/3855/specification.html

NX-HTC NX-series Advanced Temperature Control Unit...

...igit Conversion time 50 ms per Unit Sensor Input section Sensor type *1 •Thermocouple input: K, J, T, E, L, U, N, R, S, B, C/W, PL II •Platinum resistance thermometer input: Pt100 (three-wire...

https://www.omron-ap.co.th/products/family/3902/specification.html

R88D-1SN[]-ECT-51 AC Servo System 1S-series with S...

...[] * The standard shaft type is a straight shaft. A model with a key and tap is indicated with “J” at [] of the Decelerator model number. e.g. R88G-HPG11B05100BJ For 2,000-r/min Servomotors S...

https://www.omron-ap.co.th/products/family/3923/lineup.html

R88D-1SN[]-ECT-51 AC Servo System 1S-series with S...

.... 15 max. 20 max. 20 max. Backlash ° 1.2 max. 1.2 max. 1.2 max. 1.2 max. Allowable braking work J 9 9 60 60 Allowable total work J 9,000 9,000 60,000 60,000 Allowable angular acceler...

https://www.omron-ap.co.th/products/family/3923/specification.html

E5CD-H Digital Temperature Controller (48 x 48 mm)...

... 4.1 VA max. at 24 VAC or 2.3 W max. at 24 VDC Sensor input Temperature input  Thermocouple: K, J, T, E, L, U, N, R, S, B, C/W, or PL II  Platinum resistance thermometer: Pt100 or JPt100 An...

https://www.omron-ap.co.th/products/family/3937/specification.html

E5ED-H Digital Temperature Controller (48 x 96 mm)...

... 5.5 VA max. at 24 VAC or 3.2 W max. at 24 VDC Sensor input Temperature input  Thermocouple: K, J, T, E, L, U, N, R, S, B, C/W, or PL II  Platinum resistance thermometer: Pt100 or JPt100 An...

https://www.omron-ap.co.th/products/family/3938/specification.html

E2EQ Spatter-resistant Proximity Sensor/Dimensions...

...3D1 E2EQ-X7D1 E2EQ-X10D1 Pre-wired Connector Models Long Sensing-distance Models E2EQ-X4X1-M1(T)J E2EQ-X8X1-M1(T)J E2EQ-X15X1-M1(T)J Standard Models E2EQ-X3D1-M1(T)GJ E2EQ-X...

https://www.omron-ap.co.th/products/family/452/dimension.html

E2EQ Spatter-resistant Proximity Sensor/Specificat...

...tware last update: January 17, 2022 Long Sensing-distance Models Model E2EQ-X4X1 E2EQ-X4X1-M1(T)J E2EQ-X8X1 E2EQ-X8X1-M1(T)J E2EQ-X15X1 E2EQ-X15X1-M1(T)J Sensing distance 4 ...

https://www.omron-ap.co.th/products/family/452/specification.html

K3MA-L Temperature Meter/Specifications | OMRON In...

...er: (±0.5% of indication value or ±1°C, whichever greater) ±1 digit max. Input Thermocouple: K, J, T, E, L, U, N, R, S, B Platinum-resistance thermometer: JPt100, Pt100 Measurement method Dou...

https://www.omron-ap.co.th/products/family/589/specification.html

GT1-TS04[] Temperature Input Units/Specifications ...

...nit Connecting Cable (40 mm) Input Specifications Model GT1-TS04T GT1-TS04P Input type R, S, K, J, T, L, or B selectable Pt100 or Jpt100 selectable Indicator accuracy (±0.3% of indication val...

https://www.omron-ap.com.my/products/family/1083/specification.html

E5GN Basic-type Digital Temperature Controller (48...

...(max.) 24 VAC/VDC: 3 VA/2 W (max.) Sensor input Models with temperature inputs Thermocouple: K, J, T, E, L, U, N, R, S, B, W, or PL II Platinum resistance thermometer: Pt100 or JPt100 Infrare...

https://www.omron-ap.com.my/products/family/1434/specification.html

CJ1W-TC CJ Series Temperature Control Unit/Lineup ...

...s 5 V 24 V CJ1 Special I/O Units Temperature Control Units 4 loops Thermocouple input (R, S, K, J, T, B, L) Open collector NPN outputs (pulses) 2 0.25 - CJ1W-TC001 * UC1, N, L, CE 4 loops Ope...

https://www.omron-ap.com.my/products/family/1438/lineup.html

CJ1W-TC CJ Series Temperature Control Unit/Specifi...

...em Specification Model number CJ1W-TC00[] CJ1W-TC10[] Temperature sensor Thermocouple: R, S, K, J, T, L, B Platinum resistance thermometer: Pt100, JPt100 Number of loops 4 loops or 2 loops wi...

https://www.omron-ap.com.my/products/family/1438/specification.html

K3HB-H Temperature Indicator/Specifications | OMRO...

...power supply: 50 mA max. (24 VDC) Input Platinum-resistance thermometer: Pt100 Thermocouple: K, J, T, E, L, U, N, R, S, B, W A/D conversion method Delta-Sigma method External power supply See...

https://www.omron-ap.com.my/products/family/1541/specification.html

CJ1W-PTS CJ-series Process Analog I/O Unit/Lineup ...

...type Thermo- couple Input Units) 2 inputs Set sepa- rately for each input Thermo- couple: B, E, J, K, L, N, R, S, T, U, WRe5- 26, PLII DC voltage: ± 100 mV Conver- sion speed: 10 ms/ 2 inputs...

https://www.omron-ap.com.my/products/family/1644/lineup.html

CJ1W-PTS CJ-series Process Analog I/O Unit/Specifi...

... and scaling can be set individually for each of 2 inputs, which are each selectable from B, E, J, K, L, N, R, S, T, U, WRe5-26, PL II, and mV. Scaling Data to be stored in the allocated word...

https://www.omron-ap.com.my/products/family/1644/specification.html

CJ1W-CT021 CJ-series High-speed Counter Unit/Speci...

...lowed frequency of Z-pulses is 1 kHz Filter Selection Timing requirement (μs) A B C D E F G H I J 10 kHz <3 >50 >100 >23 >10 >100 >50 >100 >23 >10 50 kHz <3 >10 >20 >4.5 >10 >20 >10 >20 >4.5 ...

https://www.omron-ap.com.my/products/family/1649/specification.html

E5CS Temperature Controllers/Specifications | OMRO...

... Power consumption 100 to 240 VAC: 5 VA 24 VAC: 3 VA, 24 VDC: 2 W Sensor input Thermocouple: K, J, L Platinum resistance thermometer: Pt100, JPt100 Thermistor: E52-THE[][] Universal-input (th...

https://www.omron-ap.com.my/products/family/166/specification.html

CS1W-PTS SYSMAC CS-series Process Analog I/O Units...

.../O Units Isolated- type Thermo- couple Input Units 4 inputs Set separately for each input B, E, J, K, L, N, R, S, T, U, WRe5-26, PLII, ± 100 mV 20 ms/ 4 inputs, 10 ms/ 2 inputs Removable term...

https://www.omron-ap.com.my/products/family/1664/lineup.html