| Site Search | Product Search | IA Global Search |
...value): 500 V Note: This value was measured under the following conditions. Noise duration: 100 ns and 1μs Repetition period: 100 Hz Noise application time: 3 min Replacing the Thyristor Mod...
https://www.fa.omron.com.cn/data_pdf/cat/g3ph_j177-e1_2_2_csm1000554.pdf
...75 76 77 փ㖤ঋݹ CJ1W-NCȏȏ4 ACհᵃ⭫ᵰ/傧ࣞಞ G5㌱ࡍ ਥ㕌ぁಞ CJ2 CX-Programmer CX-Drive 儎䙕㜿ߨѨශ ਥ㕌ぁ㓾ㄥ NS㌱ࡍ ᆿޞ䗉ޛ ᆿޞಞ G9SP㌱ࡍ ᶺᔰᆿޞ⭫䐥䙐ؗ(EtherCAT)ශ ᆿޞ䗉ޛ ᆿޞಞ G9SP㌱ࡍ Sysmac Studio ᵰಞ㠠ࣞौ...
https://www.fa.omron.com.cn/data_pdf/cat/g5_series_i819-cn5_1_10.pdf
.../s2 Shock resistance Malfunction: 200 m/s2 Noise immunity Noise level: 2.0 kV; pulse width: 100 ns to 1μs Ambient temperature Operating: 0 to 55°C (with no condensation or icing) Ambient humi...
https://www.fa.omron.com.cn/data_pdf/cat/g70a_j087-e1_1_9_csm1057151.pdf
...on 100 m/s2 Noise immunity Power input (normal mode) 600 V for 10 min with a pulse width of 100 ns to 1μs Power input (common mode) 1.5 kV for 10 min with a pulse width of 100 ns to ...
https://www.fa.omron.com.cn/data_pdf/cat/g70d-soc08_ds_e_5_1_csm1046356.pdf
... terminals Noise immunity Power input (normal mode): 600 V for 10 min with a pulse width of 100 ns to 1μs Power input (common mode): 1.5 kV for 10 min with a pulse width of 100 ns to...
https://www.fa.omron.com.cn/data_pdf/cat/g70d-soc16_fom16_ds_e_4_1_csm1046357.pdf
... terminals Noise immunity Power input (normal mode): 600 V for 10 min with a pulse width of 100 ns to 1μs Power input (common mode): 1.5 kV for 10 min with a pulse width of 100 ns to...
https://www.fa.omron.com.cn/data_pdf/cat/g70d-vsoc16_-vfom16_ds_e_3_1_csm1046358.pdf
...ouble amplitude) Shock resistance 200 m/s2 Noise immunity Noise level: 1.5 kV; pulse width: 100 ns to 1μs Rated voltage between positive and negative terminal blocks Rated voltage of controll...
https://www.fa.omron.com.cn/data_pdf/cat/g7tc_ds_e_9_1_csm1046354.pdf
.../DC24~48 V时为1.5 kV 耐噪音±1.5 kV(电源端子之间)和±600 V(无电压输入端子之间),噪声模拟器生成的方波噪声(脉冲宽度:100 ns/1µs, 上升时间1 ns) 静电耐力误动作:8 kV 毁坏:15 kV 耐...
https://www.fa.omron.com.cn/data_pdf/cat/h3cr_l084-cn5_3_2.pdf
... V (between no-voltage input terminals), square-wave noise by noise simulator (pulse width: 100 ns/1μs, 1-ns rise) Static immunity Malfunction: 8 kV Destruction: 15 kV Vibration resi...
https://www.fa.omron.com.cn/data_pdf/cat/h3cr_l084-e1_3_6_csm1013792.pdf
...ZC-K2GS-N K2ZC-K2GF-N 机种OVGR(64)单相OVR(27)3相UVR(27)OVR(59) 型号K2ZC-K2GV-NC K2ZC-K2GV-NT K2ZC-K2VU-NS K2ZC-K2VU-N K2ZC-K2VA-N 机种DSR(67S)RPR(67P)UPR(91L) 型号K2ZC-K2DS-N K2...
https://www.fa.omron.com.cn/data_pdf/cat/k2zc-n_ds_c_1_1.pdf
...interface (See note 2.) Maximum transmission distance 5 m; hub delay time + cable delay time≤70 ns Maximum number of connectable Units 1 Unit USB standard V1.1 Slave device RS-485 interface M...
https://www.fa.omron.com.cn/data_pdf/cat/k3sc_ds_e_5_1_csm347.pdf
...连接的端口。 可使用市售USB电缆 ○ (可连接CX- Programmer、 CX-Designer等) ——————————————○ 内置 RS-232C 端口串行端口A (显示部) 与NS系列的SerialA、B相同。 并且还可以访问控制器。 ○——○○○———————— 串...
...ess Effort in Designing and Debugging Commercially available USB cable CX-Designer Designer for NS series CX-Programmer Ladder Programming Software (1) Power ON (2) Simply connect the USB cab...
https://www.fa.omron.com.cn/data_pdf/cat/nsj_v406-e1_7_8_csm2192.pdf
...rge Memory Capacity for Data Management Example Reflow Ovens Example YES YES LD instruction: 20 ns YES 250 to 60 Ksteps 448 to 128 Kwords 2,560 points YES YES YES YES 62 mm wide YES YES LD in...
https://www.fa.omron.com.cn/data_pdf/cat/p04e-en-03a cj1 groupcat.pdf
...Lens Lase oscillator Workpiece A hardware circuit creates an output pulse (response time: < 100 ns...
https://www.fa.omron.com.cn/data_pdf/cat/pmac_series_r192-e1_2_7_csm1058386.pdf
...- 红色亮灯存储器异常闪烁电压测量异常、电流测量异常 -熄灭无电源供给绿色/红色闪烁接通电源时网络状态指示灯(NS) 绿色亮灯已建立连接的状态闪烁未建立连接的状态红色亮灯IP地址重复状态闪烁连接处于...
https://www.fa.omron.com.cn/data_pdf/cat/s8vk-x_sgtc-cn5-067_1_11.pdf
..., QR Code (Models 1, 2), 21´21 to 57´57 (Versions 1 to 10) Power line: 2 kVp-p, Pulse width: 50 ns, Rise time: 5 ns, Consecutive burst time: 15 ms, Cycle: 300 ms 10 to 150 Hz, 0.35-m...
https://www.fa.omron.com.cn/data_pdf/cat/v400-f_q148-e1_1_5_csm1572.pdf
...AC, 50/60 Hz for 1 min between leads and Amplifier Unit case Noise immunity 1 kV, Pulse rise: 5 ns, Pulse width: 50 ns, Burst duration: 15 ms, Cycle: 300 ms Vibration resistance (des...
https://www.fa.omron.com.cn/data_pdf/cat/zfv-c_ds_e_1_2_csm1716.pdf
...AC, 50/60 Hz for 1 min between leads and Amplifier Unit case Noise immunity 1 kV, Pulse rise: 5 ns, Pulse width: 50 ns, Burst duration: 15 ms, Cycle: 300 ms Vibration resistance Dest...
https://www.fa.omron.com.cn/data_pdf/cat/zfv_ds_e_1_1_csm1717.pdf
...络构建(数据链接、路由表、通信单元设定等)时。 对CX-Intergrator的操作方法进行说明。 CX-Designer 用户手册 SBSA-532需制作可编程终端NS系列的画面数据时对CX-Designer的操作方法进行说明。 CX-Protocol ...
https://www.fa.omron.com.cn/data_pdf/mnu/70017-0302346d_nj501-4___.pdf