Site Search | Product Search | IA Global Search |
... / CAD / Software last update: April 2, 2018 (Unit: mm) Open Relays with Solder Terminals MM2(X)K, MM3(X)K, MM4(X)K Note: Connect the common (C) of MM[]XK to positive (+). O...
https://www.omron-ap.co.nz/products/family/960/dimension.html
...O Unit Connecting Cable (40 mm) Input Specifications Model GT1-TS04T GT1-TS04P Input type R, S, K, J, T, L, or B selectable Pt100 or Jpt100 selectable Indicator accuracy (±0.3% of indication ...
https://www.omron-ap.co.th/products/family/1083/specification.html
...VA (max.) 24 VAC/VDC: 3 VA/2 W (max.) Sensor input Models with temperature inputs Thermocouple: K, J, T, E, L, U, N, R, S, B, W, or PL II Platinum resistance thermometer: Pt100 or JPt100 Infr...
https://www.omron-ap.co.th/products/family/1434/specification.html
...puts 5 V 24 V CJ1 Special I/O Units Temperature Control Units 4 loops Thermocouple input (R, S, K, J, T, B, L) Open collector NPN outputs (pulses) 2 0.25 - CJ1W-TC001 * UC1, N, L, CE 4 loops ...
... Item Specification Model number CJ1W-TC00[] CJ1W-TC10[] Temperature sensor Thermocouple: R, S, K, J, T, L, B Platinum resistance thermometer: Pt100, JPt100 Number of loops 4 loops or 2 loops...
https://www.omron-ap.co.th/products/family/1438/specification.html
...ing screws): 0.5 N·m Weight 260 g max. Output Specifications per Relay Mounted relays DRTA-NY5W-K *1 Rated load Resistive load: 2 A at 250 VAC, 8 A per common 2 A at 30 VDC, 8 A per common Ra...
https://www.omron-ap.co.th/products/family/1440/specification.html
...ut - Monitor focus - Linear output correction - (A-B) calculations *4 - (A+B) calculations *4 - K-(A+B) calculation *4 - Mutual interference prevention *4 - Sensor disconnection detection - Z...
https://www.omron-ap.co.th/products/family/1457/specification.html
...The G3ZA-CT150L is for use only in combination with the G3ZA (Ver.2.0 or higher). Wire terminal k and terminal l. (Do not use terminal kt and terminal lt.) * Do not remove the attached resist...
https://www.omron-ap.co.th/products/family/1511/dimension.html
...r: 3 m PVC-covered cable with a shield wire resisting 70°C Note: 1. Based on characteristics of K-type thermocouple and radiation rate of 0.98. 2. The accuracy is given as the chan...
https://www.omron-ap.co.th/products/family/1516/specification.html
...ion Standards (OMRON's own durability evaluation standards) (Cutting oil type: specified in JIS K 2241:2000; Temperature: 35°C max.) Note1. The sensing distances for the E3NX-FA are values fo...
...et power supply: 50 mA max. (24 VDC) Input Platinum-resistance thermometer: Pt100 Thermocouple: K, J, T, E, L, U, N, R, S, B, W A/D conversion method Delta-Sigma method External power supply ...
https://www.omron-ap.co.th/products/family/1541/specification.html
...e Thermo- couple Input Units) 2 inputs Set sepa- rately for each input Thermo- couple: B, E, J, K, L, N, R, S, T, U, WRe5- 26, PLII DC voltage: ± 100 mV Conver- sion speed: 10 ms/ 2 inputs, R...
...d scaling can be set individually for each of 2 inputs, which are each selectable from B, E, J, K, L, N, R, S, T, U, WRe5-26, PL II, and mV. Scaling Data to be stored in the allocated words i...
https://www.omron-ap.co.th/products/family/1644/specification.html
...= Number of licenses (01, 03, 10) Product Model Expansion Memory Unit CPM1-EMU01-V1 EEPROM (256 K) EEROM-JD Peripheral Port Adapters and Connecting Cables Description Computer port Length Mod...
...age Power consumption 100 to 240 VAC: 5 VA 24 VAC: 3 VA, 24 VDC: 2 W Sensor input Thermocouple: K, J, L Platinum resistance thermometer: Pt100, JPt100 Thermistor: E52-THE[][] Universal-input ...
https://www.omron-ap.co.th/products/family/166/specification.html
...Units Isolated- type Thermo- couple Input Units 4 inputs Set separately for each input B, E, J, K, L, N, R, S, T, U, WRe5-26, PLII, ± 100 mV 20 ms/ 4 inputs, 10 ms/ 2 inputs Removable termina...
...alue, etc. Number of temperature sensor inputs 4 Temperature sensor types Thermocouple B, E, J, K, N, R, S, T or - 80 to 80 mV. (Set separately for each of four inputs.) Sensor type, input ra...
https://www.omron-ap.co.th/products/family/1664/specification.html
... to 115%) or 458 Ω max. (when output range is - 20 to 100%) (Refer to note.) When 1 to 5 V: 250 k Ω max. Output impedance When 1 to 5 V: 250 Ω (typical) Voltage when open between terminals Ap...
https://www.omron-ap.co.th/products/family/1669/specification.html
...anual / CAD / Software last update: November 5, 2013 Temperature Controllers Input Thermocouple K (CA) Chromel vs. alumel Standard scale (°C) 0 to 200 0 to 300 0 to 400 0 to 600 0 to 800 0 to...
...Detection voltage: 4 V DC Short-circuit current between terminals: 1.2 mA DC ON resistance: 0.8 k Ω max. OFF resistance: 5.0 k Ω min. Voltage input: Connected to voltage input termin...
https://www.omron-ap.co.th/products/family/1671/specification.html