Primary Contents

IA Global Search Results

Select Country in

Site Search Product Search IA Global Search
Results 4521 - 4540 of 21439
E5CD 温控器(数字温控器)(48 x 48 mm)/额定值 / 性能 | OMRON Indus...

.../1.6W以下(DC24V) 选项-802型 :6.5VA以下(AC100~240V)、       4.1VA以下(AC24V)/2.3W以下(DC24V) 传感器输入 温度输入  热电偶:K、J、T、E、L、U、N、R、S、B、C/W、PLⅡ  铂电阻测温体:Pt100...

https://www.fa.omron.com.cn/products/family/3668/specification.html

E5ED 温控器(数字温控器) (48 x 96 mm)/额定值 / 性能 | OMRON Indu...

....3W以下(DC24V) 选项-808型 :8.3VA以下(AC100~240V)、       5.5VA以下(AC24V)/ 3.2W以下(DC24V) 传感器输入 温度输入  热电偶 :K、 J、 T、 E、 L、 U、 N、 R、 S、 B、 C/W、 PLⅡ  铂电阻测...

https://www.fa.omron.com.cn/products/family/3669/specification.html

K3MA-L 温度指示计/指示报警表/额定值 / 性能 | OMRON Industrial Aut...

...结冰、结露) 保存时 -25~+65℃(无结冰、结露) 使用湿度 范围 使用时 相对湿度25~85%(无结露) 本体质量 约200g 性能 输入 热电偶: K、 J、 T、 E、 L、 U、 N、 R、 S、 B 铂测温电阻体: JPt100、 Pt100 ...

https://www.fa.omron.com.cn/products/family/589/specification.html

SE 电机继电器/外形尺寸 | OMRON Industrial Automation

... /CAD /软件 信息更新: 2016年4月21日 (单位:mm) 本体 插入型 SE-KP□N SE-KQP□N 注: 面板厚度为1~3.2mm。 面板安装型 SE-K□N SE-KQ□N 注: 面板厚度为1~3.2mm。 相关设备 电流变送器 SET-3A SET-3B ...

https://www.fa.omron.com.cn/products/family/842/dimension.html

SE 电机继电器/种类 | OMRON Industrial Automation

...座(8PFA1)。   有关安装状态,请参照样本。 相关设备(另售) 电流变送器 型号 适用电流范围 SET-3A 1~80A SET-3B 64~160A 变压器(SE-K□2□N用) 型号 电压规格 2次功耗 SE-PT 400 1次侧 AC380~480V...

https://www.fa.omron.com.cn/products/family/842/lineup.html

XW2Z 连接接插件端子块转换单元的专用电缆 (带屏蔽型)/种类 | OMRON Industria...

...*每个可编程控制I/O单元最多需要2根电缆。 * 电缆长度L (m) 适用于可编程控制器的32点MIL接插件型I/O单元 XW2Z-□□□K 电缆长度L (m) * 型号 0.25 XW2Z-C25K 0.5 XW2Z-C50K 1 XW2Z-100K 1.5 XW2Z-150K 2 XW2Z...

https://www.fa.omron.com.cn/products/family/871/lineup.html

MMK 闭锁继电器/外形尺寸 | OMRON Industrial Automation

...额定值 / 性能 外形尺寸 样本 / 手册・说明书 /CAD /软件 信息更新: 2013年3月27日 (单位:mm) 本体 外露型 焊锡端子 MM2(X)K MM3(X)K MM4(X)K 请将MM□XK的公共端子C连接在(+)上。 ...

https://www.fa.omron.com.cn/products/family/960/dimension.html

GT1-TS04[] Temperature Input Units/Specifications ...

...O Unit Connecting Cable (40 mm) Input Specifications Model GT1-TS04T GT1-TS04P Input type R, S, K, J, T, L, or B selectable Pt100 or Jpt100 selectable Indicator accuracy (±0.3% of indication ...

https://www.omron-ap.co.in/products/family/1083/specification.html

E5GN Basic-type Digital Temperature Controller (48...

...VA (max.) 24 VAC/VDC: 3 VA/2 W (max.) Sensor input Models with temperature inputs Thermocouple: K, J, T, E, L, U, N, R, S, B, W, or PL II Platinum resistance thermometer: Pt100 or JPt100 Infr...

https://www.omron-ap.co.in/products/family/1434/specification.html

CJ1W-TC CJ Series Temperature Control Unit/Lineup ...

...puts 5 V 24 V CJ1 Special I/O Units Temperature Control Units 4 loops Thermocouple input (R, S, K, J, T, B, L) Open collector NPN outputs (pulses) 2 0.25 - CJ1W-TC001 * UC1, N, L, CE 4 loops ...

https://www.omron-ap.co.in/products/family/1438/lineup.html

CJ1W-TC CJ Series Temperature Control Unit/Specifi...

... Item Specification Model number CJ1W-TC00[] CJ1W-TC10[] Temperature sensor Thermocouple: R, S, K, J, T, L, B Platinum resistance thermometer: Pt100, JPt100 Number of loops 4 loops or 2 loops...

https://www.omron-ap.co.in/products/family/1438/specification.html

DRT2-ROS16 Remote I/O Terminal with Relay Outputs/...

...ing screws): 0.5 N·m Weight 260 g max. Output Specifications per Relay Mounted relays DRTA-NY5W-K *1 Rated load Resistive load: 2 A at 250 VAC, 8 A per common 2 A at 30 VDC, 8 A per common Ra...

https://www.omron-ap.co.in/products/family/1440/specification.html

ZX-E Smart Sensors (Inductive Displacement Type)/S...

...ut - Monitor focus - Linear output correction - (A-B) calculations *4 - (A+B) calculations *4 - K-(A+B) calculation *4 - Mutual interference prevention *4 - Sensor disconnection detection - Z...

https://www.omron-ap.co.in/products/family/1457/specification.html

G3ZA Multi-channel Power Controller/Dimensions | O...

...The G3ZA-CT150L is for use only in combination with the G3ZA (Ver.2.0 or higher). Wire terminal k and terminal l. (Do not use terminal kt and terminal lt.) * Do not remove the attached resist...

https://www.omron-ap.co.in/products/family/1511/dimension.html

ES1B Infrared Thermosensor/Specifications | OMRON ...

...r: 3 m PVC-covered cable with a shield wire resisting 70°C Note: 1. Based on characteristics of K-type thermocouple and radiation rate of 0.98.            2. The accuracy is given as the chan...

https://www.omron-ap.co.in/products/family/1516/specification.html

E32 Series Fiber Sensors/Lineup | OMRON Industrial...

...ion Standards (OMRON's own durability evaluation standards) (Cutting oil type: specified in JIS K 2241:2000; Temperature: 35°C max.) Note1. The sensing distances for the E3NX-FA are values fo...

https://www.omron-ap.co.in/products/family/1532/lineup.html

K3HB-H Temperature Indicator/Specifications | OMRO...

...et power supply: 50 mA max. (24 VDC) Input Platinum-resistance thermometer: Pt100 Thermocouple: K, J, T, E, L, U, N, R, S, B, W A/D conversion method Delta-Sigma method External power supply ...

https://www.omron-ap.co.in/products/family/1541/specification.html

CJ1W-PTS CJ-series Process Analog I/O Unit/Lineup ...

...e Thermo- couple Input Units) 2 inputs Set sepa- rately for each input Thermo- couple: B, E, J, K, L, N, R, S, T, U, WRe5- 26, PLII DC voltage: ± 100 mV Conver- sion speed: 10 ms/ 2 inputs, R...

https://www.omron-ap.co.in/products/family/1644/lineup.html

CJ1W-PTS CJ-series Process Analog I/O Unit/Specifi...

...d scaling can be set individually for each of 2 inputs, which are each selectable from B, E, J, K, L, N, R, S, T, U, WRe5-26, PL II, and mV. Scaling Data to be stored in the allocated words i...

https://www.omron-ap.co.in/products/family/1644/specification.html

CPM2C Compact PLC series/Lineup | OMRON Industrial...

...= Number of licenses (01, 03, 10) Product Model Expansion Memory Unit CPM1-EMU01-V1 EEPROM (256 K) EEROM-JD Peripheral Port Adapters and Connecting Cables Description Computer port Length Mod...

https://www.omron-ap.co.in/products/family/1652/lineup.html

Results 4521 - 4540 of 21439

Select Country in