Site Search | Product Search | IA Global Search |
...nsions are the same for the E5CSL. (r0.5% of indication value or r1qC, whichever is greater) r1 digit max. R, S thermocouple at 200qC or less: r3qC r1 digit max. -6VJGTOQEQWRNGCV100q...
https://www.fa.omron.com.cn/data_pdf/mnu/e5csl_e5cwl_inst-2268756-9a.pdf
...stic: Indication accuracy Thermocouple: (±0.5% of indication value or±1°C, whichever greater)±1 digit max. As follows the accuracy has the exceptions by temperature range. ±2°C±1 ...
https://www.fa.omron.com.cn/data_pdf/mnu/e5cz_inst-1648080-5c.pdf
... key to change levels. •Shift key (PF key) The default PF Setting parameter is for shifting the digit. This is a function key. When it is pressed, the function set for the PF Setting paramete...
https://www.fa.omron.com.cn/data_pdf/mnu/e5dc-b_inst-2826078-9b.pdf
...couple: (Ambient temperature: 23°C) (±0.3 % of indication value or±1°C, whichever is greater)±1 digit max. Platinum resistance thermometer: (±0.2 % of indication value or±0.8°C, whichever is ...
https://www.fa.omron.com.cn/data_pdf/mnu/e5dc_inst-5377468-1a.pdf
...couple: (Ambient temperature: 23°C) (±0.3 % of indication value or±1°C, whichever is greater)±1 digit max. Platinum resistance thermometer: (±0.2 % of indication value or±0.8°C, whichever is ...
https://www.fa.omron.com.cn/data_pdf/mnu/e5ec-8___inst-2215107-4a.pdf
...couple: (Ambient temperature: 23°C) (±0.3 % of indication value or±1°C, whichever is greater)±1 digit max. Platinum resistance thermometer: (±0.2 % of indication value or±0.8°C, whichever is ...
https://www.fa.omron.com.cn/data_pdf/mnu/e5ec-8___inst-2217775-8b.pdf
...couple: (Ambient temperature: 23°C) (±0.3 % of indication value or±1°C, whichever is greater)±1 digit max. Platinum resistance thermometer: (±0.2 % of indication value or±0.8°C, whichever is ...
https://www.fa.omron.com.cn/data_pdf/mnu/e5ec-8___inst-4058510-3a.pdf
...mocouple: (Ambient temperature: 23℃) (±0.3 % of indication value or±1℃, whichever is greater)±1 digit max. Platinum resistance thermometer: (±0.2 % of indication value or±0.8℃, whichever is g...
https://www.fa.omron.com.cn/data_pdf/mnu/e5ec-_-865_inst-5377475-4a.pdf
...couple: (Ambient temperature: 23°C) (±0.3 % of indication value or±1°C, whichever is greater)±1 digit max. Platinum resistance thermometer: (±0.2 % of indication value or±0.8°C, whichever is ...
https://www.fa.omron.com.cn/data_pdf/mnu/e5ec-t_inst-2285660-4c.pdf
...couple: (Ambient temperature: 23°C) (±0.3 % of indication value or±1°C, whichever is greater)±1 digit max. Platinum resistance thermometer: (±0.2 % of indication value or±0.8°C, whichever is ...
https://www.fa.omron.com.cn/data_pdf/mnu/e5ec-t_inst-5377457-6a.pdf
...couple: (Ambient temperature: 23°C) (±0.3 % of indication value or±1°C, whichever is greater)±1 digit max. Platinum resistance thermometer: (±0.2 % of indication value or±0.8°C, whichever is ...
https://www.fa.omron.com.cn/data_pdf/mnu/e5ec-t_inst-5377458-4a.pdf
...couple: (Ambient temperature: 23°C) (±0.3 % of indication value or±1°C, whichever is greater)±1 digit max. Platinum resistance thermometer: (±0.2 % of indication value or±0.8°C, whichever is ...
https://www.fa.omron.com.cn/data_pdf/mnu/e5ec_inst-5377452-5a.pdf
...couple: (Ambient temperature: 23°C) (±0.3 % of indication value or±1°C, whichever is greater)±1 digit max. Platinum resistance thermometer: (±0.2 % of indication value or±0.8°C, whichever is ...
https://www.fa.omron.com.cn/data_pdf/mnu/e5ec_inst-5377453-3a.pdf
...)/3.2 W max. (24 VDC) Thermocouple: (±0.1 % of indication value or±1°C, whichever is greater)±1 digit max. Platinum resistance thermometer: (±0.1 % of indication value or±0.5°C, whichever is ...
https://www.fa.omron.com.cn/data_pdf/mnu/e5ed-h_inst_3690382-6a.pdf
...couple: (Ambient temperature: 23°C) (±0.1 % of indication value or±1°C, whichever is greater)±1 digit max. Platinum resistance thermometer: (±0.1 % of indication value or±0.5°C, whichever is ...
https://www.fa.omron.com.cn/data_pdf/mnu/e5en-h_inst-1661077-6e.pdf
...00 m/s2VKOGUGCEJKP:;CPF
https://www.fa.omron.com.cn/data_pdf/mnu/e5ewl_inst-2268757-7a.pdf
...ory protection 100 to 240 VAC, 50/60 Hz 85% to 110% of the rated voltage Approx. 3 VA ±(1°C + 1 digit) max. E5L-C□only. Accuracy of thermistor is not included. Relay output: 250 VAC, 10 A (re...
https://www.fa.omron.com.cn/data_pdf/mnu/e5l_inst-y8025-10023a.pdf
...h2 IO-Link Power supply Protection circuit Environment resistance Numerical value indication: 4-digit 7-segment white LED with inverting function Status indicators:The content of indication ...
https://www.fa.omron.com.cn/data_pdf/mnu/e8fc-25__series_inst-3129431-7f.pdf
...s) Flow rate monitoring*2 Temperature monitoring*6 Display method Numerical value indication: 4-digit 7-segment white LED with inverting function Status indicators:The content of indication ...
https://www.fa.omron.com.cn/data_pdf/mnu/e8fc-25s_series_inst-5696355-8a.pdf
...D-E E8PC-100ST-E 0 to 40MPa -0.10 to 44.00MPa 50MPa 80MPa 0.01MPa Numerical value indication: 4-digit 7-segment white LED with inverting function Status indicator: The content of indication ...
https://www.fa.omron.com.cn/data_pdf/mnu/e8pc-___s_series_inst-5696380-9b.pdf