E5DC-RX2DSM-017 | OMRON Industrial Automation

...C Allowable voltage variable range 85 to 110% of the power supply voltage Power consumption 1.5 W max. (at 24 VDC) 2.8 VA max. (at 24 VAC) Input Number of input points 1 point Temperature inp...

https://www.ia.omron.com/product/item/3374/

E5CB-Q1PD | OMRON Industrial Automation

...ble voltage variable range 85 to 110% of the power supply voltage Power consumption Approx. 2.5 W (at 24 VDC) Approx. 3.5 VA (at 24 VAC) Input Number of input points 1 point Temperature input...

https://www.ia.omron.com/product/item/34318/

E5CB-Q1TCD | OMRON Industrial Automation

...ble voltage variable range 85 to 110% of the power supply voltage Power consumption Approx. 2.5 W (at 24 VDC) Approx. 3.5 VA (at 24 VAC) Input Number of input points 1 point Temperature input...

https://www.ia.omron.com/product/item/34320/

E5CB-R1PD | OMRON Industrial Automation

...ble voltage variable range 85 to 110% of the power supply voltage Power consumption Approx. 2.5 W (at 24 VDC) Approx. 3.5 VA (at 24 VAC) Input Number of input points 1 point Temperature input...

https://www.ia.omron.com/product/item/34322/

E5CB-R1TCD | OMRON Industrial Automation

...ble voltage variable range 85 to 110% of the power supply voltage Power consumption Approx. 2.5 W (at 24 VDC) Approx. 3.5 VA (at 24 VAC) Input Number of input points 1 point Temperature input...

https://www.ia.omron.com/product/item/34324/

MM4XB AC200/(220) | OMRON Industrial Automation

...ltage 250 VAC 250 VDC Max. contact current AC: 15 A DC: 15 A Maximum switching power 20 VA 1200 W (Resistive load) 800 W (Inductive load (L/R = 7 ms)) Contact form 4PDT Contact metho...

https://www.ia.omron.com/product/item/35341/

MY4H AC24 | OMRON Industrial Automation

... DC: 3 A Maximum switching power 330 VA (Resistive load) 88 VA (Inductive load (cosφ = 0.4)) 72 W (Resistive load) 36 W (Inductive load (L/R = 7 ms)) Contact form 4PDT Contact method...

https://www.ia.omron.com/product/item/35416/

MY4H DC100/110 | OMRON Industrial Automation

...se voltage (Reset voltage) 10 % min. Maximum voltage 110 % (23 ℃) Power consumption Approx. 0.9 W Contact Contact rated load 110 VAC 3 A (Resistive load) 110 VAC 0.8 A (Inductive load (cosφ =...

https://www.ia.omron.com/product/item/35417/

MY4H DC48 | OMRON Industrial Automation

...se voltage (Reset voltage) 10 % min. Maximum voltage 110 % (23 ℃) Power consumption Approx. 0.9 W Contact Contact rated load 110 VAC 3 A (Resistive load) 110 VAC 0.8 A (Inductive load (cosφ =...

https://www.ia.omron.com/product/item/35418/

MY4H-0 AC110/120 | OMRON Industrial Automation

... DC: 3 A Maximum switching power 330 VA (Resistive load) 88 VA (Inductive load (cosφ = 0.4)) 72 W (Resistive load) 36 W (Inductive load (L/R = 7 ms)) Contact form 4PDT Contact method...

https://www.ia.omron.com/product/item/35419/

MY4H-0 DC24 | OMRON Industrial Automation

...se voltage (Reset voltage) 10 % min. Maximum voltage 110 % (23 ℃) Power consumption Approx. 0.9 W Contact Contact rated load 110 VAC 3 A (Resistive load) 110 VAC 0.8 A (Inductive load (cosφ =...

https://www.ia.omron.com/product/item/35420/

MY4IN-CR AC200/220 (S) | OMRON Industrial Automati...

...: 5 A Maximum switching power 1250 VA (Resistive load) 200 VA (Inductive load (cosφ = 0.4)) 150 W (Resistive load) 45 W (Inductive load (L/R = 7 ms)) Contact form 4PDT Contact method...

https://www.ia.omron.com/product/item/35423/

MY4IN-D2 DC48 (S) | OMRON Industrial Automation

...se voltage (Reset voltage) 10 % min. Maximum voltage 110 % (23 ℃) Power consumption Approx. 0.9 W Contact Contact rated load 250 VAC 3 A (Resistive load) 250 VAC 0.8 A (Inductive load (cosφ =...

https://www.ia.omron.com/product/item/35424/

MY4ZH-0 DC100/110 | OMRON Industrial Automation

...se voltage (Reset voltage) 10 % min. Maximum voltage 110 % (23 ℃) Power consumption Approx. 0.9 W Contact Contact rated load 110 VAC 3 A (Resistive load) 110 VAC 0.8 A (Inductive load (cosφ =...

https://www.ia.omron.com/product/item/35447/

MY4ZH-0 DC24 | OMRON Industrial Automation

...se voltage (Reset voltage) 10 % min. Maximum voltage 110 % (23 ℃) Power consumption Approx. 0.9 W Contact Contact rated load 110 VAC 3 A (Resistive load) 110 VAC 0.8 A (Inductive load (cosφ =...

https://www.ia.omron.com/product/item/35449/

MY4ZIN-CR AC100/110 (S) | OMRON Industrial Automat...

...: 5 A Maximum switching power 1250 VA (Resistive load) 200 VA (Inductive load (cosφ = 0.4)) 150 W (Resistive load) 45 W (Inductive load (L/R = 7 ms)) Contact form 4PDT Contact method...

https://www.ia.omron.com/product/item/35451/

MY4ZIN-CR AC200/220 (S) | OMRON Industrial Automat...

...: 5 A Maximum switching power 1250 VA (Resistive load) 200 VA (Inductive load (cosφ = 0.4)) 150 W (Resistive load) 45 W (Inductive load (L/R = 7 ms)) Contact form 4PDT Contact method...

https://www.ia.omron.com/product/item/35452/

MY4ZIN-D2 DC12 (S) | OMRON Industrial Automation

...se voltage (Reset voltage) 10 % min. Maximum voltage 110 % (23 ℃) Power consumption Approx. 0.9 W Contact Contact rated load 250 VAC 3 A (Resistive load) 250 VAC 0.8 A (Inductive load (cosφ =...

https://www.ia.omron.com/product/item/35453/

MY4ZIN-D2 DC48 (S) | OMRON Industrial Automation

...se voltage (Reset voltage) 10 % min. Maximum voltage 110 % (23 ℃) Power consumption Approx. 0.9 W Contact Contact rated load 250 VAC 3 A (Resistive load) 250 VAC 0.8 A (Inductive load (cosφ =...

https://www.ia.omron.com/product/item/35454/

MY4ZN-CBG AC100/110 | OMRON Industrial Automation

... DC: 3 A Maximum switching power 220 VA (Resistive load) 66 VA (Inductive load (cosφ = 0.4)) 24 W (Resistive load) 12 W (Inductive load (L/R = 7 ms)) Contact form 4PDT Contact method...

https://www.ia.omron.com/product/item/35455/