H3CR-AS AC24-48/DC12-48 | OMRON Industrial Automat...

...ltage: 1 V max. Open circuit impedance: 100 kΩ min. Power consumption at output ON: Approx. 0.3 W (at 24 VDC)/at output OFF: Approx. 0.2 W (at 24 VDC) Reset voltage 10% max. of rated...

https://www.ia.omron.com/product/item/3771/

H3CR-H8L AC200-240 M | OMRON Industrial Automation

... to 110% of the power supply voltage Power consumption Approx. 0.35 VA (at 240 VAC) Approx. 0.3 W (at 240 VAC) Operation start voltage 30% max. of rated supply voltage Number of time ranges 4...

https://www.ia.omron.com/product/item/3792/

H3CR-H8L AC200-240 S | OMRON Industrial Automation

... to 110% of the power supply voltage Power consumption Approx. 0.35 VA (at 240 VAC) Approx. 0.3 W (at 240 VAC) Operation start voltage 30% max. of rated supply voltage Number of time ranges 4...

https://www.ia.omron.com/product/item/3793/

H3CR-H8L DC100-125 M | OMRON Industrial Automation

...ble voltage variable range 85 to 110% of the power supply voltage Power consumption Approx. 0.5 W (at 125 VDC) Operation start voltage 30% max. of rated supply voltage Number of time ranges 4...

https://www.ia.omron.com/product/item/3794/

H3CR-H8L DC100-125 S | OMRON Industrial Automation

...ble voltage variable range 85 to 110% of the power supply voltage Power consumption Approx. 0.5 W (at 125 VDC) Operation start voltage 30% max. of rated supply voltage Number of time ranges 4...

https://www.ia.omron.com/product/item/3795/

H3CR-H8L DC48 M | OMRON Industrial Automation

...le voltage variable range 85 to 110% of the power supply voltage Power consumption Approx. 0.18 W (at 48 VDC) Operation start voltage 30% max. of rated supply voltage Number of time ranges 4 ...

https://www.ia.omron.com/product/item/3796/

H3CR-H8L DC48 S | OMRON Industrial Automation

...le voltage variable range 85 to 110% of the power supply voltage Power consumption Approx. 0.18 W (at 48 VDC) Operation start voltage 30% max. of rated supply voltage Number of time ranges 4 ...

https://www.ia.omron.com/product/item/3797/

H3CR-H8RL AC/DC24 M | OMRON Industrial Automation

... Open circuit impedance: 500 kΩ min. Power consumption Approx. 0.17 VA (at 24 VAC) Approx. 0.15 W (at 24 VAC)/Approx. 1 W (at 24 VDC) Operation start voltage 30% max. of rated supply...

https://www.ia.omron.com/product/item/3798/

H3CR-H8RL AC/DC24 S | OMRON Industrial Automation

... Open circuit impedance: 500 kΩ min. Power consumption Approx. 0.17 VA (at 24 VAC) Approx. 0.15 W (at 24 VAC)/Approx. 1 W (at 24 VDC) Operation start voltage 30% max. of rated supply...

https://www.ia.omron.com/product/item/3799/

H3CR-H8RL AC100-120 M | OMRON Industrial Automatio...

...Open circuit impedance: 500 kΩ min. Power consumption Approx. 0.23 VA (at 120 VAC) Approx. 0.22 W (at 120 VAC) Operation start voltage 30% max. of rated supply voltage Number of time ranges 4...

https://www.ia.omron.com/product/item/3800/

H3CR-H8RL AC100-120 S | OMRON Industrial Automatio...

...Open circuit impedance: 500 kΩ min. Power consumption Approx. 0.23 VA (at 120 VAC) Approx. 0.22 W (at 120 VAC) Operation start voltage 30% max. of rated supply voltage Number of time ranges 4...

https://www.ia.omron.com/product/item/3801/

H3CR-H8RL AC200-240 M | OMRON Industrial Automatio...

... Open circuit impedance: 500 kΩ min. Power consumption Approx. 0.35 VA (at 240 VAC) Approx. 0.3 W (at 240 VAC) Operation start voltage 30% max. of rated supply voltage Number of time ranges 4...

https://www.ia.omron.com/product/item/3802/

H3CR-H8RL AC200-240 S | OMRON Industrial Automatio...

... Open circuit impedance: 500 kΩ min. Power consumption Approx. 0.35 VA (at 240 VAC) Approx. 0.3 W (at 240 VAC) Operation start voltage 30% max. of rated supply voltage Number of time ranges 4...

https://www.ia.omron.com/product/item/3803/

H3CR-H8RL DC100-125 M | OMRON Industrial Automatio...

...N) residual voltage: 1 V max. Open circuit impedance: 500 kΩ min. Power consumption Approx. 0.5 W (at 125 VDC) Operation start voltage 30% max. of rated supply voltage Number of time ranges 4...

https://www.ia.omron.com/product/item/3804/

H3CR-H8RL DC100-125 S | OMRON Industrial Automatio...

...N) residual voltage: 1 V max. Open circuit impedance: 500 kΩ min. Power consumption Approx. 0.5 W (at 125 VDC) Operation start voltage 30% max. of rated supply voltage Number of time ranges 4...

https://www.ia.omron.com/product/item/3805/

H3CR-H8RL DC48 M | OMRON Industrial Automation

...) residual voltage: 1 V max. Open circuit impedance: 500 kΩ min. Power consumption Approx. 0.18 W (at 48 VDC) Operation start voltage 30% max. of rated supply voltage Number of time ranges 4 ...

https://www.ia.omron.com/product/item/3806/

H3CR-H8RL DC48 S | OMRON Industrial Automation

...) residual voltage: 1 V max. Open circuit impedance: 500 kΩ min. Power consumption Approx. 0.18 W (at 48 VDC) Operation start voltage 30% max. of rated supply voltage Number of time ranges 4 ...

https://www.ia.omron.com/product/item/3807/

H3CR-HRL AC/DC24 M | OMRON Industrial Automation

... Open circuit impedance: 500 kΩ min. Power consumption Approx. 0.17 VA (at 24 VAC) Approx. 0.15 W (at 24 VAC)/Approx. 1 W (at 24 VDC) Operation start voltage 30% max. of rated supply...

https://www.ia.omron.com/product/item/3808/

H3CR-HRL AC/DC24 S | OMRON Industrial Automation

... Open circuit impedance: 500 kΩ min. Power consumption Approx. 0.17 VA (at 24 VAC) Approx. 0.15 W (at 24 VAC)/Approx. 1 W (at 24 VDC) Operation start voltage 30% max. of rated supply...

https://www.ia.omron.com/product/item/3809/

H3CR-HRL AC100-120 M | OMRON Industrial Automation

...Open circuit impedance: 500 kΩ min. Power consumption Approx. 0.23 VA (at 120 VAC) Approx. 0.22 W (at 120 VAC) Operation start voltage 30% max. of rated supply voltage Number of time ranges 4...

https://www.ia.omron.com/product/item/3810/