Site Search | Product Search | IA Global Search |
...S8VK-G Look at product details Narrow down items by specs. Relays with Forcibly Guided Contacts G7SA Look at product details Narrow down items by specs. Close Close Item(s) to be added to the...
https://www.omron-ap.com/solution/panel/suggest_selection/299/6036/?recommendation_type=10
... list Create a new BOM Completed Open BOMs Latest Products Relays with Forcibly Guided Contacts G7SA Look at product details Narrow down items by specs. Reset the conditions Re-select the pro...
https://www.omron-ap.com/solution/panel/suggest_selection/312/5958/?recommendation_type=10
...漏电流0.1mA以下输出类型源型输出(PNP) 额定输出电流0.7A以下/点 ON残留电压1.2V以下漏电流0.1mA以下使用继电器G7SA-2A2B、EN50205 Class A 故障率 P水准(参考值*) DC5V 1mA 额定负载(电阻负载)AC240...
https://www.fa.omron.com.cn/data_pdf/cat/devicenet_sbcd-cn5-093_20_18.pdf
... 0.7 A max./output ON residual voltage 1.2 V max. Leakage current 0.1 mA max. Applicable relays G7SA-2A2B, EN50205 Class A Failure rate P level * (Reference value) 5 VDC, 1 mA Rated load (res...
https://www.fa.omron.com.cn/data_pdf/cat/drt2_devicenet_q102-e1_20_37_csm2147.pdf
...に-Sがつきます。 (例) 形F3SJ-E0185P25-S *2. 検出幅(mm)=センサ全長 アクセサリ(別売) セーフティリレー 種類 形状 仕様 形式 形G7SA セーフティリレー ・極数:4極 ・接点構成:2A2B ・開閉...
....7A以下/点 ON残電圧 1.2V以下 漏れ電流 0.1mA以下 ■安全出力仕様 (リレー出力) (形DST1-MRD08SL-1) 使用リレー 形G7SA-2A2B、EN50205 Class A 故障率 DC5V 1mA P水準 (参考値 *) 定格負荷 (抵抗負...
https://www.fa.omron.co.jp/data_pdf/cat/drt2(devicenet)_sbcd-093_20_52.pdf
...ズ G7Xシリーズ G7Zシリーズ MKシリーズ MMシリーズ G7Kシリーズ MMKシリーズ MYKシリーズ G7Sシリーズ G7SAシリーズ LYシリーズ G7TCシリーズ MYAシリーズ P7T(F)シリーズ PYシリーズ 推奨代替商品なし ■...
...ax. Safety Output Specifications (Relay Output) (DST1-MRD08SL-1) 150m/s2 11ms Applicable relays G7SA-2A2B, EN50205 Class A Failure rate P level * (Reference value) 5 VDC, 1 mA Rated load (res...
https://www.fa.omron.co.jp/data_pdf/cat/drt2_devicenet_q102-e1_20_37_csm2147.pdf
...公司官网 欧姆龙自动化(中国)有限公司官网 注:点击 可进入下载页面 名称 样本 手册 软件 说明书 常见问题 G7S-□-E G7SA...
... で 厚 み は 0.3mm ~ 0.5mm 程度のため、ケースに尖ったものを当てると、穴が開くことがあります。 P WB 実 装 タイプ の G7J, G7SAでも発生する可能性があります。 リレー端子によるケース穴開き リレー...
https://www.fa.omron.co.jp/data_pdf/mnu/sgfr-330g_relay_tg.pdf
... case by a relay terminal Caution This problem may even occur with the PWB-mounted type G7J and G7SA. Solution Hole made in a case by a relay terminal 1. After relays are mounted on circuit b...
https://www.fa.omron.co.jp/data_pdf/mnu/z384-e1-04_relay_tg.pdf
...case, it may make a hole. Caution This problem may even occur with the PWB-mounted type G7J and G7SA. Solution 34 Case Swelling This phenomenon causes the top and sides of the case of a relay...
https://www.fa.omron.com.cn/data_pdf/mnu/z384-e1-04_relay_tg.pdf
...ng contact welding. There are 4 products of Safety Relays. Relays with Forcibly Guided Contacts G7SA Compact, Slim Relays Conforming to EN Standards Relays with Forcibly Guided Contacts G7S-[...
https://www.omron-ap.com/products/category/safety-components/safety-relays/index.html
...ng contact welding. There are 4 products of Safety Relays. Relays with Forcibly Guided Contacts G7SA Compact, Slim Relays Conforming to EN Standards Relays with Forcibly Guided Contacts G7S-[...
https://www.omron-ap.co.nz/products/category/safety-components/safety-relays/index.html
...ng contact welding. There are 4 products of Safety Relays. Relays with Forcibly Guided Contacts G7SA Compact, Slim Relays Conforming to EN Standards Relays with Forcibly Guided Contacts G7S-[...
https://www.omron-ap.co.th/products/category/safety-components/safety-relays/index.html
...ng contact welding. There are 4 products of Safety Relays. Relays with Forcibly Guided Contacts G7SA Compact, Slim Relays Conforming to EN Standards Relays with Forcibly Guided Contacts G7S-[...
https://www.omron-ap.com.my/products/category/safety-components/safety-relays/index.html
...ng contact welding. There are 4 products of Safety Relays. Relays with Forcibly Guided Contacts G7SA Compact, Slim Relays Conforming to EN Standards Relays with Forcibly Guided Contacts G7S-[...
https://www.omron-ap.com.ph/products/category/safety-components/safety-relays/index.html
...ng contact welding. There are 4 products of Safety Relays. Relays with Forcibly Guided Contacts G7SA Compact, Slim Relays Conforming to EN Standards Relays with Forcibly Guided Contacts G7S-[...
https://www.omron.co.id/products/category/safety-components/safety-relays/index.html
...ng contact welding. There are 4 products of Safety Relays. Relays with Forcibly Guided Contacts G7SA Compact, Slim Relays Conforming to EN Standards Relays with Forcibly Guided Contacts G7S-[...
https://www.omron.com.au/products/category/safety-components/safety-relays/index.html
...ng contact welding. There are 4 products of Safety Relays. Relays with Forcibly Guided Contacts G7SA Compact, Slim Relays Conforming to EN Standards Relays with Forcibly Guided Contacts G7S-[...
https://www.omron.com.vn/products/category/safety-components/safety-relays/index.html